Literature DB >> 29670983

Infrared laser dissociation of single megadalton polymer ions in a gated electrostatic ion trap: the added value of statistical analysis of individual events.

Mohammad A Halim1, Christian Clavier, Xavier Dagany, Michel Kerleroux, Philippe Dugourd, Robert C Dunbar, Rodolphe Antoine.   

Abstract

In this study, we report the unimolecular dissociation mechanism of megadalton SO3-containing poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PAMPS) polymer cations and anions with the aid of infrared multiphoton dissociation coupled to charge detection ion trap mass spectrometry. A gated electrostatic ion trap ("Benner trap") is used to store and detect single gaseous polymer ions generated by positive and negative polarity in an electrospray ionization source. The trapped ions are then fragmented due to the sequential absorption of multiple infrared photons produced from a continuous-wave CO2 laser. Several fragmentation pathways having distinct signatures are observed. Highly charged parent ions characteristically adopt a distinctive "stair-case" pattern (assigned to the "fission" process) whereas low charge species take on a "funnel like" shape (assigned to the "evaporation" process). Also, the log-log plot of the dissociation rate constants as a function of laser intensity between PAMPS positive and negative ions is significantly different.

Entities:  

Year:  2018        PMID: 29670983     DOI: 10.1039/c8cp00404h

Source DB:  PubMed          Journal:  Phys Chem Chem Phys        ISSN: 1463-9076            Impact factor:   3.676


  3 in total

1.  Effects of Individual Ion Energies on Charge Measurements in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).

Authors:  Andrew G Elliott; Conner C Harper; Haw-Wei Lin; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2018-11-14       Impact factor: 3.109

2.  Enhanced Multiplexing in Fourier Transform Charge Detection Mass Spectrometry by Decoupling Ion Frequency from Mass to Charge Ratio.

Authors:  Conner C Harper; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2019-11-12       Impact factor: 3.109

3.  STORI Plots Enable Accurate Tracking of Individual Ion Signals.

Authors:  Jared O Kafader; Steven C Beu; Bryan P Early; Rafael D Melani; Kenneth R Durbin; Vlad Zabrouskov; Alexander A Makarov; Joshua T Maze; Deven L Shinholt; Ping F Yip; Neil L Kelleher; Philip D Compton; Michael W Senko
Journal:  J Am Soc Mass Spectrom       Date:  2019-09-11       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.