Literature DB >> 29666952

Utility of diffusion-weighted MR imaging in the diagnosis of placenta accreta spectrum abnormality.

Bhagya Sannananja1, Anna Ellermeier2,3, Daniel S Hippe2, Thomas C Winter4, Stella K Kang5, Susanna I Lee6, Mark R Kilgore7, Manjiri K Dighe2.   

Abstract

PURPOSE: The aim of this study was to evaluate the utility of added DWI sequences as an adjunct to traditional MR imaging in the evaluation of abnormal placentation in patients with suspicion for placenta accreta spectrum abnormality or morbidly adherent placenta (MAP).
MATERIALS AND METHODS: The study was approved by local ethics committee. The subjects included pregnant women with prenatal MRI performed between July 2013 to July 2015. All imaging was performed on a Philips 1.5T MR scanner using pelvic phased-array coil. Only T2-weighted and diffusion-weighted imaging (DWI) series were compiled for review. Two randomized imaging sets were created: set 1 included T2-weighted series only (T2W); set 2 included T2W with DWI series together (T2W + DWI). Three radiologists, blinded to history and pathology, reviewed the imaging, with 2 weeks of time between the two image sets. Sensitivity, specificity, and overall accuracy for MAP were calculated and compared between T2W only and T2W + DWI reads. Associations between imaging findings and invasion on pathology were tested using the Chi-squared test. Confidence scores, inter-reader agreement, and systematic differences were documented.
RESULTS: A total of 17 pregnant women were included in the study. 8 cases were pathologically diagnosed with MAP. There were no significant differences in the diagnostic accuracy between T2W and T2W + DWI in the diagnosis of MAP in terms of overall accuracy (62.7% for T2W vs. 68.6% for T2W + DWI, p = 0.68), sensitivity (70.8% for T2W vs. 95.8% for T2W + DWI, p = 0.12), and specificity (55.6% for T2W vs. 44.4% for T2W + DWI, p = 0.49). There was no significant difference in the diagnostic confidence between the review of T2W images alone and the T2W + DWI review (mean 7.3 ± 1.8 for T2W vs. 7.5 ± 1.8 for T2W + DWI, p = 0.37).
CONCLUSION: With the current imaging technique, addition of DWI sequence to the traditional T2W images cannot be shown to significantly increase the accuracy or reader confidence for diagnosis of placenta accreta spectrum abnormality. However, DWI does improve identification of abnormalities in the placental-myometrial interface.

Entities:  

Keywords:  DWI; Diffusion-weighted MR; MAP; Morbidly adherent placenta; Placenta accreta spectrum abnormality

Year:  2018        PMID: 29666952     DOI: 10.1007/s00261-018-1599-8

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  3 in total

1.  Magnetic resonance imaging for placenta accreta: hope for the future.

Authors:  Grace Lim; Marc Lim; Jeanne M Horowitz
Journal:  Am J Obstet Gynecol       Date:  2019-07-24       Impact factor: 8.661

2.  Standard diffusion-weighted, diffusion kurtosis and intravoxel incoherent motion MR imaging of the whole placenta: a pilot study of volumetric analysis.

Authors:  Tao Lu; Yishuang Wang; Aiwen Guo; Cui Wei; Yazheng Chen; Shaoyu Wang; Bin Song
Journal:  Ann Transl Med       Date:  2022-03

3.  Normative placental structure in pregnancy using quantitative Magnetic Resonance Imaging.

Authors:  Nickie Andescavage; Kushal Kapse; Yuan-Chiao Lu; Scott D Barnett; Marni Jacobs; Alexis C Gimovsky; Homa Ahmadzia; Jessica Quistorff; Catherine Lopez; Nicole Reinholdt Andersen; Dorothy Bulas; Catherine Limperopoulos
Journal:  Placenta       Date:  2021-07-31       Impact factor: 3.287

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.