Literature DB >> 29663178

Validation of contrast-enhanced time-resolved magnetic resonance angiography in pre-ablation planning in patients with atrial fibrillation: comparison with traditional technique.

Tarek Zghaib1, Adeel Shahid2, Chiara Pozzessere2, Kristin K Porter3, Linda C Chu2, John Eng2, Hugh Calkins4, Ihab R Kamel2, Saman Nazarian5, Stefan L Zimmerman2.   

Abstract

Bolus timing is critical to optimal magnetic resonance angiography (MRA) acquisitions but can be challenging in some patients. Our purpose was to evaluate whether contrast-enhanced time-resolved magnetic resonance angiography (TR-MRA), a dynamic multiphase sequence that does not rely on bolus timing, is a viable alternative method to conventional 3D fast-long angle shot contrast-enhanced magnetic resonance angiography (CE-MRA). Coronal subtracted conventional CE-MRA images in 50 consecutive patients presenting for pre-atrial fibrillation ablation pulmonary venous (PV) mapping were compared with 50 TR-MRA images performed in 50 subsequent patients. The TR-MRA protocol was modified to optimize spatial resolution with slightly reduced temporal resolution (6.1 s scan time). Three experienced readers evaluated each scan's image quality and relative left atrial (LA) opacification based on a 4-point scale and diagnostic PV visualization in a binary fashion. Additionally, LA signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and PV dimensions were measured for both techniques. TR-MRA had significantly higher overall image quality (3.10 ± 0.69 vs. 2.42 ± 0.69, p < 0.0001), and LA opacification scores (3.33 ± 0.70 vs. 2.15 ± 1.13, p < 0.0001) compared to CE-MRA. The proportion of diagnostically visualized pulmonary veins was 137/150 (91%) in the CE-MRA group vs. 147/150 (98%) with TR-MRA (p = 0.010). Both SNR and CNR were higher with TR-MRA vs. CE-MRA (277.9 ± 48.9 vs. 106.8 ± 41, p = 0.002 and 100.3 ± 41.7 vs. 70.7 ± 48.0, p = 0.002, respectively). Inter-reader variance of individual PV measurements for each of the MR techniques ranged between 0.62 and 1.47 mm and the ICC for vein measurements was higher with TR-MRA (range: 0.62-0.81) compared to CE-MRA (range: 0.47-0.64). TR-MRA, modified to maximize spatial resolution, offers an alternative method for performing high quality MRA examinations in patients with AF. TR-MRA offers greater overall image quality, PV visualization, and similarly reproducible PV measurements compared to traditional CE-MRA, without the challenges of proper bolus timing.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Contrast-enhanced magnetic resonance angiography; Time-resolved magnetic resonance angiography

Mesh:

Year:  2018        PMID: 29663178      PMCID: PMC6093807          DOI: 10.1007/s10554-018-1355-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  13 in total

1.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Europace       Date:  2012-03-01       Impact factor: 5.214

Review 2.  Evaluating the left atrium by magnetic resonance imaging.

Authors:  Thomas H Hauser; Dana C Peters; John V Wylie; Warren J Manning
Journal:  Europace       Date:  2008-11       Impact factor: 5.214

3.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

4.  Time-resolved contrast-enhanced 3D MR angiography.

Authors:  F R Korosec; R Frayne; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

5.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

6.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.

Authors:  M Haïssaguerre; P Jaïs; D C Shah; A Takahashi; M Hocini; G Quiniou; S Garrigue; A Le Mouroux; P Le Métayer; J Clémenty
Journal:  N Engl J Med       Date:  1998-09-03       Impact factor: 91.245

Review 7.  Percutaneous ablation for atrial fibrillation: the role of cross-sectional imaging.

Authors:  Benoit Ghaye; David Szapiro; Jean-Nicolas Dacher; Luz-Maria Rodriguez; Carl Timmermans; David Devillers; Robert F Dondelinger
Journal:  Radiographics       Date:  2003-10       Impact factor: 5.333

8.  Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 Study.

Authors:  Sumeet S Chugh; Rasmus Havmoeller; Kumar Narayanan; David Singh; Michiel Rienstra; Emelia J Benjamin; Richard F Gillum; Young-Hoon Kim; John H McAnulty; Zhi-Jie Zheng; Mohammad H Forouzanfar; Mohsen Naghavi; George A Mensah; Majid Ezzati; Christopher J L Murray
Journal:  Circulation       Date:  2013-12-17       Impact factor: 29.690

9.  Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA.

Authors:  Florian M Vogt; Jens M Theysohn; Dariusz Michna; Peter Hunold; Ulrich Neudorf; Sonja Kinner; Jörg Barkhausen; Harald H Quick
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

Review 10.  Imaging in percutaneous ablation for atrial fibrillation.

Authors:  Ruzica Maksimović; Thorsten Dill; Arsen D Ristić; Petar M Seferović
Journal:  Eur Radiol       Date:  2006-05-20       Impact factor: 7.034