Literature DB >> 2965638

[Percutaneously implantable balloon-inflatable vascular prostheses. Initial clinical results].

E P Strecker1, P Romaniuk, B Schneider, M Westphal, E Zeitler, H R Wolf, N Freudenberg.   

Abstract

Restenosis and occlusion of atherosclerotic arteries are prevented by a newly developed arterial prosthesis consisting of a pliable and elastic wire mesh tube positioned to the balloon of an angioplasty catheter. As the balloon is inflated the prosthesis dilates and provides the arterial wall with a new mechanical support. This new device was successfully implanted in ten patients having an iliac artery stenosis and improved the therapeutic result of the preceding angioplasty. There were no complications.

Entities:  

Mesh:

Year:  1988        PMID: 2965638     DOI: 10.1055/s-2008-1067678

Source DB:  PubMed          Journal:  Dtsch Med Wochenschr        ISSN: 0012-0472            Impact factor:   0.628


  6 in total

1.  Historical overview on the development and characteristics of stents and future outlooks.

Authors:  C L Zollikofer; F Antonucci; G Stuckmann; P Mattias; E K Salomonowitz
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Sep-Oct       Impact factor: 2.740

2.  Stent placement in iliac arterial lesions: three years of clinical experience with the Wallstent.

Authors:  D Vorwerk; R W Günther
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Sep-Oct       Impact factor: 2.740

3.  Evaluation of ferromagnetism and magnetic resonance imaging artifacts of the Strecker tantalum vascular stent.

Authors:  G P Teitelbaum; M Raney; M J Carvlin; A H Matsumoto; K H Barth
Journal:  Cardiovasc Intervent Radiol       Date:  1989 May-Jun       Impact factor: 2.740

4.  Self-expanding stents for the treatment of a long venous stenosis in a dialysis shunt: case report.

Authors:  R W Günther; D Vorwerk; K C Klose; K Bohndorf; D Kistler; H Mann; H G Sieberth
Journal:  Cardiovasc Intervent Radiol       Date:  1989 Jan-Feb       Impact factor: 2.740

5.  Iliac and femoropopliteal vascular occlusive disease treated with flexible tantalum stents.

Authors:  E P Strecker; B Hagen; D Liermann; B Schneider; H R Wolf; J Wambsganss
Journal:  Cardiovasc Intervent Radiol       Date:  1993 May-Jun       Impact factor: 2.740

6.  Follow-up results after stent placement in failing arteriovenous shunts: a three-year experience.

Authors:  D Vorwerk; R W Günther; K Bohndorf; D Kistler; U Gladziwa; H G Sieberth
Journal:  Cardiovasc Intervent Radiol       Date:  1991 Sep-Oct       Impact factor: 2.740

  6 in total