R W Günther1, D Vorwerk, K C Klose, K Bohndorf, D Kistler, H Mann, H G Sieberth.
Abstract
This report describes the successful management of a long venous stenosis that resulted from intimal hyperplasia in a synthetic hemodialysis graft. The recurrent stenosis was kept patent with four overlapping, self-expanding metallic stents, which allowed coverage of the 16 cm distance from the axillary vein to the synthetic graft.Entities:
Mesh:
Year: 1989 PMID: 2496924 DOI: 10.1007/bf02577122