Equivalence Testing of Complex Particle Size Distribution Profiles Based on Earth Mover's Distance.

Meng Hu1, Xiaohui Jiang1, Mohammad Absar1, Stephanie Choi1, Darby Kozak1, Meiyu Shen2, Yu-Ting Weng2, Liang Zhao3, Robert Lionberger1.   

Abstract

Particle size distribution (PSD) is an important property of particulates in drug products. In the evaluation of generic drug products formulated as suspensions, emulsions, and liposomes, the PSD comparisons between a test product and the branded product can provide useful information regarding in vitro and in vivo performance. Historically, the FDA has recommended the population bioequivalence (PBE) statistical approach to compare the PSD descriptors D50 and SPAN from test and reference products to support product equivalence. In this study, the earth mover's distance (EMD) is proposed as a new metric for comparing PSD particularly when the PSD profile exhibits complex distribution (e.g., multiple peaks) that is not accurately described by the D50 and SPAN descriptor. EMD is a statistical metric that measures the discrepancy (distance) between size distribution profiles without a prior assumption of the distribution. PBE is then adopted to perform statistical test to establish equivalence based on the calculated EMD distances. Simulations show that proposed EMD-based approach is effective in comparing test and reference profiles for equivalence testing and is superior compared to commonly used distance measures, e.g., Euclidean and Kolmogorov-Smirnov distances. The proposed approach was demonstrated by evaluating equivalence of cyclosporine ophthalmic emulsion PSDs that were manufactured under different conditions. Our results show that proposed approach can effectively pass an equivalent product (e.g., reference product against itself) and reject an inequivalent product (e.g., reference product against negative control), thus suggesting its usefulness in supporting bioequivalence determination of a test product to the reference product which both possess multimodal PSDs.

Entities:  

Keywords:  earth mover’s distance; equivalence test; particle size distribution; profile comparison

Mesh:

Substances:

Year:  2018        PMID: 29651627     DOI: 10.1208/s12248-018-0212-y

Source DB:  PubMed          Journal:  AAPS J        ISSN: 1550-7416            Impact factor:   4.009


  8 in total

1.  Commentary on the FDA draft guidance for bioequivalence studies for nasal aerosols and nasal sprays for local action: an industry view.

Authors:  L I Harrison
Journal:  J Clin Pharmacol       Date:  2000-07       Impact factor: 3.126

2.  An efficient Earth Mover's Distance algorithm for robust histogram comparison.

Authors:  Haibin Ling; Kazunori Okada
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2007-05       Impact factor: 6.226

3.  Application of the modified chi-square ratio statistic in a stepwise procedure for cascade impactor equivalence testing.

Authors:  Benjamin Weber; Sau L Lee; Renishkumar Delvadia; Robert Lionberger; Bing V Li; Yi Tsong; Guenther Hochhaus
Journal:  AAPS J       Date:  2014-12-17       Impact factor: 4.009

Review 4.  In vitro bioequivalence approach for a locally acting gastrointestinal drug: lanthanum carbonate.

Authors:  Yongsheng Yang; Rakhi B Shah; Lawrence X Yu; Mansoor A Khan
Journal:  Mol Pharm       Date:  2013-01-04       Impact factor: 4.939

5.  Quality by design approach for understanding the critical quality attributes of cyclosporine ophthalmic emulsion.

Authors:  Ziyaur Rahman; Xiaoming Xu; Usha Katragadda; Yellela S R Krishnaiah; Lawrence Yu; Mansoor A Khan
Journal:  Mol Pharm       Date:  2014-01-24       Impact factor: 4.939

6.  A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability.

Authors:  D J Schuirmann
Journal:  J Pharmacokinet Biopharm       Date:  1987-12

7.  On population and individual bioequivalence.

Authors:  R Schall; H G Luus
Journal:  Stat Med       Date:  1993-06-30       Impact factor: 2.373

8.  Earth Mover's Distance (EMD): A True Metric for Comparing Biomarker Expression Levels in Cell Populations.

Authors:  Darya Y Orlova; Noah Zimmerman; Stephen Meehan; Connor Meehan; Jeffrey Waters; Eliver E B Ghosn; Alexander Filatenkov; Gleb A Kolyagin; Yael Gernez; Shanel Tsuda; Wayne Moore; Richard B Moss; Leonore A Herzenberg; Guenther Walther
Journal:  PLoS One       Date:  2016-03-23       Impact factor: 3.240

  8 in total
  1 in total

1.  Increasing the Batch Size of a QESD Crystallization by Using a MSMPR Crystallizer.

Authors:  Jerome Hansen; Peter Kleinebudde
Journal:  Pharmaceutics       Date:  2022-06-09       Impact factor: 6.525

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.