Literature DB >> 29628751

Construction and Test Results of Coils 2 and 3 of a 3-Nested-Coil 800-MHz REBCO Insert for the MIT 1.3-GHz LTS/HTS NMR Magnet.

Dongkeun Park1, Juan Bascuñán1, Philip C Michael1, Jiho Lee1, Seungyong Hahn2, Yukikazu Iwasa1.   

Abstract

We present construction and test results of Coils 2 and 3 of a 3-coil 800-MHz REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under construction. Each of three H800 coils (Coils 1-3) is a stack of no-insulation REBCO double pancakes (DPs). The innermost 8.67-T Coil 1 (26 DPs) was completed in 2016; the middle 5.64-T Coil 2 (32 DPs) has been wound, assembled, and tested; and for the outermost 4.44-T Coil 3, its 38 DPs have been wound and preliminary tests were performed to characterize each DP at 77 K. Included for Coil 2 are: 1) 77-K data of critical current, index, and turn-to-turn characteristic resistivity of each DP; 2) stacking order of the 32 DPs optimized to maximize the Coil 2 current margin and minimize its Joule dissipation in the pancake-to-pancake joints; 3) procedure to experimentally determine and apply a room-temperature preload to the DP stack; 4) 77-K and 4.2-K test results after each of 64 pancakes was over-banded with 75-μm-thick stainless steel tape for a radial thickness of 5 mm. Presented for each DP in Coil 3 are 77-K dada of critical current, index, and turn-to-turn characteristic resistivity.

Entities:  

Keywords:  1.3 GHz LTS/HTS NMR magnet; HTS insert; REBCO; high field; no-insulation winding technique

Year:  2017        PMID: 29628751      PMCID: PMC5884159          DOI: 10.1109/TASC.2017.2780043

Source DB:  PubMed          Journal:  IEEE Trans Appl Supercond


  1 in total

1.  Construction and Test Results of Coil 2 of a Three-Coil 800-MHz REBCO Insert for the 1.3-GHz High-Resolution NMR Magnet.

Authors:  Juan Bascuñán; Philip Michael; Seungyong Hahn; Thibault Lecrevisse; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2016-12-21
  1 in total
  5 in total

1.  Quench Analyses of the MIT 1.3-GHz LTS/HTS NMR Magnet.

Authors:  So Noguchi; Dongkeun Park; Yoonhyuch Choi; Jiho Lee; Yi Li; Philip C Michael; Juan Bascuñán; Seungyong Hahn; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2019-03-06

2.  Experimental and Numerical Studies on a Method to Mitigate Screening Current-Induced Field for No-Insulation REBCO Coils.

Authors:  Jiho Lee; Dongkeun Park; Yi Li; Yoon Hyuck Choi; Philip C Michael; Juan Bascuñân; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2019-03-27

3.  Design Overview of the MIT 1.3-GHz LTS/HTS NMR Magnet with a New REBCO Insert.

Authors:  Dongkeun Park; Juan Bascuñán; Yi Li; Wooseung Lee; Yoonhyuck Choi; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2021-03-04

4.  MIT 1.3-GHz LTS/HTS NMR Magnet: Post Quench Analysis and New 800-MHz Insert Design.

Authors:  Dongkeun Park; Juan Bascuñán; Philip C Michael; Jiho Lee; Yoon Hyuck Choi; Yi Li; Seungyong Hahn; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2019-02-22

5.  Assembly and Test of a 3-Nested-Coil 800-MHz REBCO Insert (H800) for the MIT 1.3 GHz LTS/HTS NMR Magnet.

Authors:  Philip C Michael; Dongkeun Park; Yoon Hyuck Choi; Jiho Lee; Yi Li; Juan Bascuñán; So Noguchi; Seungyong Hahn; Yukikazu Iwasa
Journal:  IEEE Trans Appl Supercond       Date:  2019-02-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.