Does Patient-Specific Instrumentation Improve Femoral and Tibial Component Alignment in Total Knee Arthroplasty? A Prospective Randomized Study.

Artur Stolarczyk1, Lukasz Nagraba2, Tomasz Mitek2, Magda Stolarczyk2, Jarosław Michał Deszczyński3, Maciej Jakucinski4.   

Abstract

Alignment of the prosthesis is one of the most significant factors that affect the long-term clinical outcome following total knee arthroplasty (TKA). There is conflicting evidence whether patient-specific instrumentation (PSI) for TKA improves the component position compared to standard instrumentation. This study aimed to compare the rotational alignment of the femoral and tibial components in TKA patients when performed with either conventional or PSI. Sixty patients with primary knee osteoarthritis were randomly divided into two groups treated surgically with TKA: one with conventional instrumentation and the other with the Visionaire PSI system (Smith and Nephew, Memphis, TN). Computerized tomography (CT) and X-ray imaging were performed preoperatively and 12 weeks after surgery. The rotational alignment of the femoral and tibial component in all patients was assessed postsurgically using CT imaging according to the Berger protocol. Both groups were clinically assessed in a blinded fashion using the Knee Society Score (KSS) and a visual analog scale (VAS). Fifty-eight patients were prospectively assessed. The mean postsurgical follow-up was 3.0 ± 0.4 months. CT images did not reveal any significant improvement in the rotational alignment of the implant components between the groups. X-rays revealed a significant improvement in the deviation from the optimal alignment range of the femoral component in the coronal plane in both groups. Patients operated with Visionaire PSI assistance had poorer functional outcomes. We conclude that there were no improvements in clinical outcomes or knee component alignment in patients treated with PSI compared with those treated with standard instruments. In addition, clinical and functional assessment showed inferior results in terms of KSS and VAS scores at the midterm follow-up in patients treated with PSI.

Entities:  

Keywords:  Computerized tomography; Femoral component rotation; Knee arthroplasty; Patient-specific instrumentation; Rotational alignment; Tibia

Mesh:

Year:  2018        PMID: 29623574     DOI: 10.1007/5584_2018_193

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   2.622


  6 in total

1.  Clinical and radiologic outcomes of two patellar resection techniques during total knee arthroplasty: a prospective randomized controlled study.

Authors:  Fuzhen Yuan; Zewen Sun; Haijun Wang; Yourong Chen; Jiakuo Yu
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

Review 2.  Methods of intra- and post-operative determination of the position of the tibial component during total knee replacement.

Authors:  Roman Popescu; Emil G Haritinian; Stefan Cristea
Journal:  Int Orthop       Date:  2019-10-27       Impact factor: 3.075

3.  Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.

Authors:  Reha N Tandogan; Nanne P Kort; Ersin Ercin; Floris van Rooij; Luca Nover; Mo Saffarini; Michael T Hirschmann; Roland Becker; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-03-01       Impact factor: 4.114

4.  The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty.

Authors:  Kwangkyoun Kim; Jungsung Kim; Dokyoung Lee; Sohui Lim; Jiyoon Eom
Journal:  Knee Surg Relat Res       Date:  2019-03-01

5.  Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies.

Authors:  Branavan Rudran; Henry Magill; Nikhil Ponugoti; Andy Williams; Simon Ball
Journal:  BMC Musculoskelet Disord       Date:  2022-07-23       Impact factor: 2.562

6.  Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.

Authors:  Kazuha Kizaki; Ajaykumar Shanmugaraj; Fumiharu Yamashita; Nicole Simunovic; Andrew Duong; Vickas Khanna; Olufemi R Ayeni
Journal:  BMC Musculoskelet Disord       Date:  2019-11-23       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.