Literature DB >> 29615293

Implant stability using piezoelectric bone surgery compared with conventional drilling: a systematic review and meta-analysis.

S García-Moreno1, J González-Serrano2, R M López-Pintor1, B Pardal-Peláez1, G Hernández1, J M Martínez-González1.   

Abstract

The aim of this systematic review was to assess the primary and secondary stability of dental implants placed at sites prepared with piezoelectric bone surgery (PBS) and conventional drilling (CD). The PubMed/MEDLINE and Cochrane Library databases were searched without date or language restriction up to June 2017. Controlled clinical trials in which each patient received implants placed at sites prepared with both PBS and CD were selected. Implant stability had to be measured on day 0 and during the osseointegration period. Methodological quality was assessed using the Cochrane Collaboration tool. A meta-analysis was performed to compare primary stability (on day 0) and secondary stability (after 2 and 3months) between the two groups. The studies included were determined to have a high risk of bias. There was no significant difference between the two groups for primary stability (on day 0) (P=0.51). After 2 and 3months, secondary stability was statistically higher in implants placed with PBS preparation (P=0.04 and P=0.01, respectively). The implant survival rate was 97.5% in the CD group and 100% in the PBS group. PBS preparation improves secondary stability after 2 and 3months in comparison to CD, with similar implant survival rates. Further studies are needed to determine whether implant osseointegration periods could be shortened with PBS preparation.
Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  implant site preparation; implant stability; meta-analysis; piezoelectric surgery; resonance frequency analysis

Mesh:

Substances:

Year:  2018        PMID: 29615293     DOI: 10.1016/j.ijom.2018.03.004

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  2 in total

1.  Effects of Different Undersizing Site Preparations on Implant Stability.

Authors:  Bernardo Ferreira Lemos; Paula Lopez-Jarana; Carlos Falcao; Blanca Ríos-Carrasco; Javier Gil; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

2.  Piezoelectric Implant Site Preparation: Influence of Handpiece Movements on Temperature Elevation.

Authors:  Luca Lamazza; Marco Lollobrigida; Iole Vozza; Luigi Palmieri; Claudio Stacchi; Teresa Lombardi; Alberto De Biase
Journal:  Materials (Basel)       Date:  2020-09-14       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.