Literature DB >> 29605282

Accuracy of 8 intraocular lens calculation formulas in relation to anterior chamber depth in patients with normal axial lengths.

Sabite Emine Gökce1, Ildamaris Montes De Oca1, David L Cooke1, Li Wang1, Douglas D Koch1, Zaina Al-Mohtaseb2.   

Abstract

PURPOSE: To determine the effect of anterior chamber depth (ACD) on the accuracy of 8 intraocular lens calculation formulas in patients with normal axial lengths (ALs).
SETTING: Baylor College of Medicine, Alkek Eye center, Houston, Texas, USA.
DESIGN: Retrospective case series.
METHODS: Patients having cataract surgery with ALs between 22.0 mm and 25.0 mm were divided into 3 groups based on their preoperative ACD measurement. The mean prediction errors, mean absolute errors (MAEs), and median absolute errors for each group were calculated.
RESULTS: For the ACD of 3.0 mm or less group and the ACD of 3.5 mm or more group, the Barrett Universal II, Holladay 2, Haigis, and Olsen ray-tracing formulas had mean prediction error values that were not significantly different from zero. For the ACD of 3.01 to 3.49 mm group, all formulas had mean prediction error values that were not significantly different from zero. For the ACD of 3.0 mm or less group, the Barrett Universal II formula had a smaller median absolute error than the Haigis, Hoffer Q, and Olsen optical low-coherence reflectometry (OLCR) (Lenstar) formulas and a smaller MAE than the Hoffer Q, Hill-RBF, and Olsen OLCR (P < .05). In the ACD of 3.5 mm or more group, the Barrett MAE was smaller than the Hoffer Q (P < .05); however, there were no significant differences between median absolute errors.
CONCLUSION: In eyes with normal ALs, taking preoperative ACD values into consideration might improve refractive outcomes.
Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 29605282     DOI: 10.1016/j.jcrs.2018.01.015

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Accuracy of new-generation intraocular lens calculation formulas in eyes with variations in predicted refraction.

Authors:  Pingjun Chang; Shuyi Qian; Yalan Wang; Siyan Li; Fuman Yang; Yiwen Hu; Zhuohan Liu; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-08       Impact factor: 3.117

2.  Accuracy of different lens power calculation formulas in patients with phacomorphic glaucoma.

Authors:  Seyed Ali Tabatabaei; Melika Samadi; Mohammad Soleimani; Hosein Fonoodi; Sepideh Ghods; Bahman Inanloo
Journal:  Taiwan J Ophthalmol       Date:  2022-04-13

3.  Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David Piñero
Journal:  Int Ophthalmol       Date:  2022-02-08       Impact factor: 2.029

4.  Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas.

Authors:  Min Hou; Yujie Ding; Liangping Liu; Jianbing Li; Xing Liu; Mingxing Wu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-07-14       Impact factor: 3.117

Review 5.  Recurring themes during cataract assessment and surgery.

Authors:  Shruti Chandra; Sobha Sivaprasad; Paul G Ursell; Khayam Naderi; David O'Brart; Amar Alwitry; Mayank A Nanavaty
Journal:  Eye (Lond)       Date:  2021-04-29       Impact factor: 4.456

6.  New Approach for the Calculation of the Intraocular Lens Power Based on the Fictitious Corneal Refractive Index Estimation.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Ophthalmol       Date:  2019-05-14       Impact factor: 1.909

7.  Improving clinical refractive results of cataract surgery by machine learning.

Authors:  Martin Sramka; Martin Slovak; Jana Tuckova; Pavel Stodulka
Journal:  PeerJ       Date:  2019-07-02       Impact factor: 2.984

8.  Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients.

Authors:  Jinhai Huang; Yuyu Zhao; Giacomo Savini; Guanshun Yu; Jinjin Yu; Zhongxing Chen; Ruixue Tu; Yune Zhao
Journal:  J Ophthalmol       Date:  2020-05-15       Impact factor: 1.909

9.  Accuracy of intraocular lens calculation formulas for eyes with insufficient capsular support.

Authors:  Zhouyue Li; Zhangkai Lian; Charlotte Aimee Young; Jing Zhao; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2021-02

10.  Effect of cataract surgery on vision-related quality of life among cataract patients with high myopia: a prospective, case-control observational study.

Authors:  Yehui Tan; Liangping Liu; Jianbing Li; Yingyan Qin; Ao Sun; Mingxing Wu
Journal:  Eye (Lond)       Date:  2021-07-21       Impact factor: 4.456

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.