Literature DB >> 29602536

Contemporary Dual Mobility Head Penetration at Five Years: Concern for the Additional Convex Bearing Surface?

Evan R Deckard1, Khalid A Azzam2, R Michael Meneghini2.   

Abstract

BACKGROUND: Dual mobility (DM) bearings are increasingly popular and second-generation designs contain highly cross-linked polyethylene. The purpose of this study is to report head penetration rates in modern DM bearings.
METHODS: A review of 63 consecutive DM bearings was performed. Radiographs were analyzed for head penetration using Martell methodology at regular postoperative intervals.
RESULTS: Thirty-four DM bearings were analyzed. Mean linear head penetration was 1.59 mm/y at 1 year, 1.07 mm/y at 2 years, and 0.27 mm/y at 5 years following an exponential regression model (R2 = 0.999). Mean volumetric wear was 783 mm3/y at 1 year, 555 mm3/y at 2 years, and 104 mm3/y at 5 years following an exponential regression model (R2 = 0.986).
CONCLUSION: Initial head penetration of DM bearings is larger than contemporary cross-linked polyethylene bearings; however, rates approach steady state after 2 years, analogous to traditional bearings. The larger "bedding-in" head penetration may be due to the additional convex bearing surface, creating 2 surfaces for deformation/wear.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bearing wear; dual mobility; femoral head penetration; highly cross-linked polyethylene; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29602536     DOI: 10.1016/j.arth.2018.02.061

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  Adverse Local Tissue Reaction due to Acetabular Corrosion in Modular Dual-Mobility Constructs.

Authors:  Kevin A Sonn; R Michael Meneghini
Journal:  Arthroplast Today       Date:  2020-12-04

2.  Polyethylene wear of dual mobility cups: a comparative analysis based on patient-specific finite element modeling.

Authors:  Julien Wegrzyn; Alexander Antoniadis; Ehsan Sarshari; Matthieu Boubat; Alexandre Terrier
Journal:  Int Orthop       Date:  2022-01-12       Impact factor: 3.075

3.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.