| Literature DB >> 29594341 |
Marcin Cyprowski1, Agata Stobnicka-Kupiec2, Anna Ławniczek-Wałczyk2, Aleksandra Bakal-Kijek2, Małgorzata Gołofit-Szymczak2, Rafał L Górny2.
Abstract
PURPOSE: The objective of this study was to assess exposure to anaerobic bacteria released into air from sewage and sludge at workplaces from a wastewater treatment plant (WWTP).Entities:
Keywords: Anaerobic bacteria; Exposure assessment; PCR; Size distribution; Wastewater treatment plant
Mesh:
Substances:
Year: 2018 PMID: 29594341 PMCID: PMC6002452 DOI: 10.1007/s00420-018-1307-6
Source DB: PubMed Journal: Int Arch Occup Environ Health ISSN: 0340-0131 Impact factor: 3.015
The concentrations of anaerobic bacteria in sewage and sludge samples
| Sampling point symbol | Name of sampling point | Concentration | ||
|---|---|---|---|---|
| GMa | GSDb | |||
| Sewage [× 104 CFU/mL] | ||||
| S1 | Raw sewage (before the bar screens) | 177.5 | 5.49 | 85.4 |
| S2 | Sewage from primary settling tank | 50.7 | ||
| S3 | Leachate from fermented sludge | 0.018 | ||
| ANOVA | ||||
| Sewage sludge [× 104 CFU/g] | ||||
| S4 | Screens | 425.0 | 142.7 | 5.1 |
| S5 | Sand from grit remover | 390.0 | ||
| S6 | Dry sludge transported into incineration | 17.6 | ||
| ANOVA | ||||
aGeometric mean
bGeometric standard deviation
The characteristics of sampling point selected for the assessment of airborne anaerobic bacteria in a wastewater treatment plant
| Sampling point symbol | Name of sampling point | Temperature (°C) | Relative humidity (%) | ||||||
|---|---|---|---|---|---|---|---|---|---|
| July | February | July | February | ||||||
| GMa | GSDb | GM | GSD | GM | GSD | GM | GSD | ||
| A1 | Bar screens | 24.8 | 1.01 | 12.7 | 1.04 | 57.5 | 1.01 | 63.9 | 1.09 |
| A2 | Containers with solids in the screens’ hall | 24.2 | 1.01 | 13.2 | 1.01 | 58.0 | 1.02 | 63.9 | 1.09 |
| A3 | Primary settling tank—entrance to the control room | 24.5 | 1.04 | 6.1 | 1.14 | 58.0 | 1.00 | 73.4 | 1.07 |
| A4 | Sewage sludge pumping station | 24.1 | 1.01 | 14.5 | 1.01 | 58.0 | 1.05 | 40.0 | 1.04 |
| A5 | Aeration basins | 30.9 | 1.06 | 6.7 | 1.02 | 39.9 | 1.11 | 67.0 | 1.00 |
| A6 | Incineration plant—sludge chute | 23.0 | 1.00 | 9.3 | 1.01 | 61.0 | 1.02 | 67.0 | 1.00 |
| A7 | Incineration plant—control room | 23.8 | 1.00 | 21.8 | 1.00 | 52.5 | 1.04 | 43.5 | 1.05 |
| A8 | Sludge-thickening building—press and compactors | 24.8 | 1.00 | 14.3 | 1.04 | 67.5 | 1.03 | 59.5 | 1.01 |
| A9 | Sludge-thickening building—conveyor belts | 24.5 | 1.00 | 7.1 | 1.05 | 59.5 | 1.01 | 69.9 | 1.08 |
| A10 | Sludge-thickening building—control room | 24.5 | 1.01 | 21.8 | 1.00 | 56.0 | 1.05 | 40.5 | 1.02 |
| A11 | Background | 29.2 | 1.04 | 7.2 | 1.03 | 40.8 | 1.15 | 59.4 | 1.06 |
aGeometric mean
bGeometric standard deviation
The concentrations of anaerobic bacteria in the air at workplaces in the wastewater treatment plant
| Technological process (sampling point symbols) | July | February | TOTAL | ||||||
|---|---|---|---|---|---|---|---|---|---|
| GMa (CFU/m3) | GSDb | Range (min–max)c | GM (CFU/m3) | GSD | Range (min–max) | GM (CFU/m3) | GSD | Range (min–max) | |
| Mechanical treatment (A1–A3) | 77 | 3.16 | 21–184 | 765 | 6.59 | 99–4057 | 243 | 6.54 | 21–4057 |
| Sewage sludge treatment (A4, A8–A10) | 16 | 3.35 | 0–64 | 16 | 4.79 | 0–134 | 16 | 3.65 | 0–134 |
| Biological treatment (A5) | 127 | – | – | 21 | – | – | 52 | 3.55 | – |
| Sludge incineration (A6, A7) | 22 | 1.91 | 14–35 | 89 | 1.91 | 57–141 | 44 | 2.62 | 14–141 |
| Total | 34 | 3.45 | 0–184 | 75 | 8.69 | 0–4057 | 50 | 5.83 | 0–4057 |
| Background (A11) | 49 | – | – | 7 | – | – | 19 | 3.96 | – |
aGeometric mean
bGeometric standard deviation
cMin. minimal value, max maximal value
Qualitative characteristics of anaerobic bacteria present in the wastewater treatment plant samples
| Genus/species | Sewage and sludge | Air | Risk groupa | |||||
|---|---|---|---|---|---|---|---|---|
| Sewage (S1–S3) | Sewage sludge (S4–S6) | Mechanical treatment (A1–A3) | Sewage sludge treatment (A4, A8–A10) | Biological treatment (A5) | Sludge incineration (A6, A7) | Background (A11) | ||
| + | + | + | + | + | 2 | |||
|
| + | + | + | + | + | + | 2 | |
|
| + | + | + | + | 2 | |||
|
| + | + | + | 2 | ||||
| + | 1 | |||||||
|
| + | + | 1 | |||||
|
| + | 1 | ||||||
| + | + | + | + | + | + | + | 1 | |
| + | + | 2 | ||||||
|
| + | + | + | + | + | 2 | ||
|
| + | 2 | ||||||
|
| + | + | + | + | + | 2 | ||
|
| + | + | + | + | + | + | 2 | |
|
| + | + | + | + | 1 | |||
|
| + | + | 1 | |||||
| + | + | + | + | + | 1 | |||
|
| + | 1 | ||||||
|
| + | 1 | ||||||
|
| + | + | 1 | |||||
| + | + | + | + | + | 1 | |||
|
| + | 1 | ||||||
aAccording to the Directive 2000/54/EC
Fig. 1Electrophoretic analysis of PCR product using primers specific to the genus Clostridium (Chis150f/ClostIr). As the matrix, DNA isolated from pure cultures of specific strains (identified based on API 20A test) was used 1, Clostridium beijerinckii; 2, Clostridium botulinum; 3, Clostridium perfringens; 4, negative control (instead of DNA, 1 µl of sterile deionised water was added); M, DNA marker
Fig. 2Size distribution of anaerobic bacteria at workplaces in the wastewater treatment plant