Accuracy of Bioelectrical Impedance Analysis in Estimated Longitudinal Fat-Free Mass Changes in Male Army Cadets.

Raquel D Langer1, Catarina N Matias2, Juliano H Borges1, Vagner X Cirolini1, Mauro A Páscoa1, Gil Guerra-Júnior1, Ezequiel M Gonçalves1.   

Abstract

Introduction: Bioelectrical impedance analysis (BIA) is a practical and rapid method for making a longitudinal analysis of changes in body composition. However, most BIA validation studies have been performed in a clinical population and only at one moment, or point in time (cross-sectional study). The aim of this study is to investigate the accuracy of predictive equations based on BIA with regard to the changes in fat-free mass (FFM) in Brazilian male army cadets after 7 mo of military training. The values used were determined using dual-energy X-ray absorptiometry (DXA) as a reference method. Materials and
Methods: The study included 310 male Brazilian Army cadets (aged 17-24 yr). FFM was measured using eight general predictive BIA equations, with one equation specifically applied to this population sample, and the values were compared with results obtained using DXA. The student's t-test, adjusted coefficient of determination (R2), standard error of estimation (SEE), Lin's approach, and the Bland-Altman test were used to determine the accuracy of the predictive BIA equations used to estimate FFM in this population and between the two moments (pre- and post-moment).
Results: The FFM measured using the nine predictive BIA equations, and determined using DXA at the post-moment, showed a significant increase when compared with the pre-moment (p < 0.05). All nine predictive BIA equations were able to detect FFM changes in the army cadets between the two moments in a very similar way to the reference method (DXA). However, only the one BIA equation specific to this population showed no significant differences in the FFM estimation between DXA at pre- and post-moment of military routine. All predictive BIA equations showed large limits of agreement using the Bland-Altman approach.
Conclusion: The eight general predictive BIA equations used in this study were not found to be valid for analyzing the FFM changes in the Brazilian male army cadets, after a period of approximately 7 mo of military training. Although the BIA equation specific to this population is dependent on the amount of FFM, it appears to be a good alternative to DXA for assessing FFM in Brazilian male army cadets.

Mesh:

Year:  2018        PMID: 29590470     DOI: 10.1093/milmed/usx223

Source DB:  PubMed          Journal:  Mil Med        ISSN: 0026-4075            Impact factor:   1.437


  1 in total

1.  No differences in the body fat after violating core bioelectrical impedance measurement assumptions.

Authors:  Arshdeep K Randhawa; Veronica Jamnik; Michael D T Fung; Adam S Fogel; Jennifer L Kuk
Journal:  BMC Public Health       Date:  2021-03-12       Impact factor: 3.295

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.