Literature DB >> 29588682

Avoiding Coronary Occlusion and Root Rupture in TAVI - The Role of Pre-procedural Imaging and Prosthesis Selection.

Marco Barbanti1.   

Abstract

Coronary occlusion and rupture of the aortic root or annulus remain two major concerns of transcatheter aortic valve implantation technique. Despite their relatively low frequency they raised the interest of the scientific community as they carry an extremely poor prognosis. Prosthesis type and size selection is part of the patient selection process that allows the operator to prevent these complications. In this article, the techniques used either during pre-TAVI screening or during the procedure itself to avoid coronary occlusion and aortic rupture will be discussed.

Entities:  

Keywords:  TAVI; aortic rupture; bailout PCI; complications; coronary occlusion

Year:  2015        PMID: 29588682      PMCID: PMC5808514          DOI: 10.15420/icr.2015.10.2.94

Source DB:  PubMed          Journal:  Interv Cardiol        ISSN: 1756-1485


  22 in total

1.  Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies.

Authors:  Philippe Généreux; Stuart J Head; Nicolas M Van Mieghem; Susheel Kodali; Ajay J Kirtane; Ke Xu; Craig Smith; Patrick W Serruys; A Pieter Kappetein; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2012-04-11       Impact factor: 24.094

2.  Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.

Authors:  Omar K Khalique; Susheel K Kodali; Jean-Michel Paradis; Tamim M Nazif; Mathew R Williams; Andrew J Einstein; Gregory D Pearson; Kishore Harjai; Kendra Grubb; Isaac George; Martin B Leon; Rebecca T Hahn
Journal:  Circ Cardiovasc Imaging       Date:  2013-11-12       Impact factor: 7.792

Review 3.  Coronary obstruction in transcatheter aortic valve-in-valve implantation: preprocedural evaluation, device selection, protection, and treatment.

Authors:  Danny Dvir; Jonathon Leipsic; Philipp Blanke; Henrique B Ribeiro; Ran Kornowski; Augusto Pichard; Joseph Rodés-Cabau; David A Wood; Dion Stub; Itsik Ben-Dor; Gabriel Maluenda; Raj R Makkar; John G Webb
Journal:  Circ Cardiovasc Interv       Date:  2015-01       Impact factor: 6.546

4.  Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.

Authors:  Philipp Blanke; Jochen Reinöhl; Christian Schlensak; Matthias Siepe; Gregor Pache; Wulf Euringer; Annette Geibel-Zehender; Christopher Bode; Mathias Langer; Friedhelm Beyersdorf; Manfred Zehender
Journal:  Circ Cardiovasc Interv       Date:  2012-08-07       Impact factor: 6.546

5.  Transcatheter aortic bioprosthesis dislocation: technical aspects and midterm follow-up.

Authors:  Gian Paolo Ussia; Marco Barbanti; Kunal Sarkar; Patrizia Aruta; Marilena Scarabelli; Valeria Cammalleri; Sebastiano Immè; Anna Maria Pistritto; Simona Gulino; Massimiliano Mulè; Wanda Deste; Stefano Cannata; Corrado Tamburino
Journal:  EuroIntervention       Date:  2012-03       Impact factor: 6.534

6.  Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

Authors:  Marco Barbanti; Tae-Hyun Yang; Josep Rodès Cabau; Corrado Tamburino; David A Wood; Hasan Jilaihawi; Phillip Blanke; Raj R Makkar; Azeem Latib; Antonio Colombo; Giuseppe Tarantini; Rekha Raju; Ronald K Binder; Giang Nguyen; Melanie Freeman; Henrique B Ribeiro; Samir Kapadia; James Min; Gudrun Feuchtner; Ronen Gurtvich; Faisal Alqoofi; Marc Pelletier; Gian Paolo Ussia; Massimo Napodano; Fabio Sandoli de Brito; Susheel Kodali; Bjarne L Norgaard; Nicolaj C Hansson; Gregor Pache; Sergio J Canovas; Hongbin Zhang; Martin B Leon; John G Webb; Jonathon Leipsic
Journal:  Circulation       Date:  2013-06-07       Impact factor: 29.690

7.  Underexpansion and ad hoc post-dilation in selected patients undergoing balloon-expandable transcatheter aortic valve replacement.

Authors:  Marco Barbanti; Jonathon Leipsic; Ronald Binder; Danny Dvir; John Tan; Melanie Freeman; Bjarne Norgaard; Nicolaj Hansson; Anson Cheung; Jian Ye; Tae-Hyun Yang; Kasia Maryniak; Rekha Raju; Angus Thompson; Philipp Blanke; Sandra Lauck; David Wood; John Webb
Journal:  J Am Coll Cardiol       Date:  2013-11-06       Impact factor: 24.094

Review 8.  Coronary obstruction following transcatheter aortic valve implantation: a systematic review.

Authors:  Henrique Barbosa Ribeiro; Luis Nombela-Franco; Marina Urena; Michael Mok; Sergio Pasian; Daniel Doyle; Robert DeLarochellière; Mélanie Côté; Louis Laflamme; Hugo DeLarochellière; Ricardo Allende; Eric Dumont; Josep Rodés-Cabau
Journal:  JACC Cardiovasc Interv       Date:  2013-04-17       Impact factor: 11.195

Review 9.  Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis.

Authors:  George C M Siontis; Peter Jüni; Thomas Pilgrim; Stefan Stortecky; Lutz Büllesfeld; Bernhard Meier; Peter Wenaweser; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2014-07-15       Impact factor: 24.094

10.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

View more
  4 in total

Review 1.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

2.  Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report.

Authors:  Masaki Tsuda; Isamu Mizote; Takashi Mukai; Yasushi Sakata
Journal:  Eur Heart J Case Rep       Date:  2020-05-26

3.  Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI.

Authors:  Alexander Meyer; Markus Kofler; Matteo Montagner; Axel Unbehaun; Simon Sündermann; Semih Buz; Christoph Klein; Christof Stamm; Natalia Solowjowa; Maximilian Y Emmert; Volkmar Falk; Jörg Kempfert
Journal:  Sci Rep       Date:  2020-07-01       Impact factor: 4.379

Review 4.  How to Avoid Coronary Occlusion During TAVR Valve-in-Valve Procedures.

Authors:  Roberto Valvo; Giuliano Costa; Marco Barbanti
Journal:  Front Cardiovasc Med       Date:  2019-11-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.