Literature DB >> 2958278

Electromyographic evaluation of back muscle fatigue with repeated sustained contractions of different strengths.

H Seidel1, H Beyer, D Bräuer.   

Abstract

The aim of the study was to obtain information on changes in surface electromyograms from the lumbar erector spinae muscles during fatiguing isometric contractions. Four male subjects held different target extension forces to fatique in a prone position under carefully controlled biomechanical conditions. Standard deviations of the distribution of EMG amplitudes (RMS values), autoregressive (AR) time series models of the 15th order and spectral densities were computed. At lower force levels, i.e., at about 50 to 100 Nm or 20-40% of estimated maximum voluntary contraction force (MVC), RMS values significantly decreased over time; at the highest level examined (on average 162 Nm), they increased. Over all force levels, the explained variances of AR models increased and mean power frequencies (MPF) decreased with increasing force. The first and second AR coefficients also exhibited significant changes, depending on both contraction time and strength. The AR time series structure of EMGs during short isometric test contractions at the lowest force level within 30 s after the failure point clearly indicated muscle fatigue and some differences remained in their dependence on the preceding force. The results suggest a concept of 'selective fatigue', and provide a basis for refined electromyographic evaluation of back muscle fatigue. Such an evaluation has to consider the force history preceding the failure point, or serious errors become unavoidable. The increase in RMS values does not constitute a criterion of back muscle fatigue at low force levels. AR time series models are recommended for the description of fatigue-induced electromyographic changes.

Entities:  

Mesh:

Year:  1987        PMID: 2958278     DOI: 10.1007/bf00635375

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  31 in total

1.  An electromyographic investigation of postural fatigue in low back pain--a preliminary study.

Authors:  W J Jayasinghe; R H Harding; J A Anderson; B J Sweetman
Journal:  Electromyogr Clin Neurophysiol       Date:  1978 Jun-Aug

2.  Changes in the waveform of the electromyogram during fatiguing activity in the muscles of the spine and hips: the analysis of postural stress.

Authors:  J D Troup; A E Chapman
Journal:  Electromyogr Clin Neurophysiol       Date:  1972-10

Review 3.  Long-term effects of whole-body vibration: a critical survey of the literature.

Authors:  H Seidel; R Heide
Journal:  Int Arch Occup Environ Health       Date:  1986       Impact factor: 3.015

4.  A comparison of electromyographic and mechanical fatigue properties in motor units of the cat hindlimb.

Authors:  H P Clamann; A J Robinson
Journal:  Brain Res       Date:  1985-02-18       Impact factor: 3.252

5.  The load on the lumbar spine during isometric strength testing.

Authors:  T H Hansson; S J Bigos; M K Wortley; D M Spengler
Journal:  Spine (Phila Pa 1976)       Date:  1984-10       Impact factor: 3.468

6.  The load on the lumbo-sacral joint and trunk muscle activity during lifting.

Authors:  J Ekholm; U P Arborelius; G Németh
Journal:  Ergonomics       Date:  1982-02       Impact factor: 2.778

Review 7.  Motor unit and muscle activity in voluntary motor control.

Authors:  H J Freund
Journal:  Physiol Rev       Date:  1983-04       Impact factor: 37.312

8.  Contractility of muscle during prolonged static and repetitive dynamic activity.

Authors:  H Monod
Journal:  Ergonomics       Date:  1985-01       Impact factor: 2.778

9.  Myoelectric signal processing: optimal estimation applied to electromyography--Part I: derivation of the optimal myoprocessor.

Authors:  N Hogan; R W Mann
Journal:  IEEE Trans Biomed Eng       Date:  1980-07       Impact factor: 4.538

Review 10.  Myoelectrical manifestations of localized muscular fatigue in humans.

Authors:  C J De Luca
Journal:  Crit Rev Biomed Eng       Date:  1984
View more
  10 in total

1.  Muscle fibre directions of iliocostalis and multifidus: male-female differences.

Authors:  H J Biedermann; J L DeFoa; W J Forrest
Journal:  J Anat       Date:  1991-12       Impact factor: 2.610

2.  Mechanically corrected EMG for the continuous estimation of erector spinae muscle loading during repetitive lifting.

Authors:  J R Potvin; R W Norman; S M McGill
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

3.  Electromyography of lumbar erector spinae muscles--influence of posture, interelectrode distance, strength, and fatigue.

Authors:  R Rosenburg; H Seidel
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

4.  Frequency analysis of electromyographically measured covert speech behavior.

Authors:  A B Dollins; F J McGuigan
Journal:  Pavlov J Biol Sci       Date:  1989 Jan-Mar

5.  The relationship between the electromyogram-amplitude and isometric extension torques of neck muscles at different positions of the cervical spine.

Authors:  F Queisser; R Blüthner; D Bräuer; H Seidel
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

6.  Trunk extensor endurance and its relationship to electromyogram parameters.

Authors:  J H van Dieën; H H Oude Vrielink; A F Housheer; F B Lötters; H M Toussaint
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

7.  Back extensor muscle endurance test scores in coal miners in Australia.

Authors:  Mark Stewart; Jane Latimer; Michael Jamieson
Journal:  J Occup Rehabil       Date:  2003-06

8.  Spectral analysis of electromyogram in lumbar muscles: fatigue induced endurance contraction.

Authors:  T Tsuboi; T Satou; K Egawa; Y Izumi; M Miyazaki
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

9.  Quantification of erector spinae muscle fatigue during prolonged, dynamic lifting tasks.

Authors:  J R Potvin; R W Norman
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

10.  Low-profile elastic exosuit reduces back muscle fatigue.

Authors:  Erik P Lamers; Juliana C Soltys; Keaton L Scherpereel; Aaron J Yang; Karl E Zelik
Journal:  Sci Rep       Date:  2020-09-29       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.