Duodenoscope-Related Outbreak of a Carbapenem-Resistant Klebsiella pneumoniae Identified Using Advanced Molecular Diagnostics.

Romney M Humphries1, Shuan Yang1, Stephen Kim2, Venkatara Raman Muthusamy2, Dana Russell3, Alisa M Trout3, Teresa Zaroda3, Quen J Cheng4, Grace Aldrovandi5, Daniel Zachary Uslan3, Peera Hemarajata1, Zachary Aaron Rubin3.   

Abstract

Background: Carbapenem-resistant Klebsiella pneumoniae infections are increasingly prevalent in North American hospitals. We describe an outbreak of carbapenem-resistant K. pneumoniae containing the blaOXA-232 gene transmitted by contaminated duodenoscopes during endoscopic retrograde cholangiopancreatography (ERCP) procedures.
Methods: An outbreak investigation was performed when 9 patients with blaOXA-232 carbapenem-resistant K. pneumoniae infections were identified at a tertiary care hospital. The investigation included 2 case-control studies, review of duodenoscope reprocessing procedures, and culture of devices. Carbapenem-resistant Enterobacteriacieae (CRE) isolates were evaluated with polymerase chain reaction analysis for carbapenemase genes, and isolates with the blaOXA-232 gene were subjected to whole-genome sequencing and chromosome single-nucleotide polymorphism analysis. On recognition of ERCP as a key risk factor for infection, targeted patient notification and CRE screening cultures were performed.
Results: Molecular testing ultimately identified 17 patients with blaOxa-232 carbapenem-resistant K. pneumoniae isolates, including 9 with infections, 7 asymptomatic carriers who had undergone ERCP, and 1 additional patient who had been hospitalized in India and was probably the initial carrier. Two case-control studies established a point-source outbreak associated with 2 specific duodenoscopes. A field investigation of the use, reprocessing, and storage of deuodenoscopes did not identify deviations from US Food and Drug Administration or manufacturer recommendations for reprocessing. Conclusions: This outbreak demonstrated the previously underappreciated potential for duodenoscopes to transmit disease, even after undergoing high-level disinfection according to manufacturers' guidelines.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29579235     DOI: 10.1093/cid/cix527

Source DB:  PubMed          Journal:  Clin Infect Dis        ISSN: 1058-4838            Impact factor:   9.079


  14 in total

Review 1.  Duodenoscope-associated infections: a review.

Authors:  Gheorghe G Balan; Catalin Victor Sfarti; Stefan Andrei Chiriac; Carol Stanciu; Anca Trifan
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-09-03       Impact factor: 3.267

2.  Epidemiology and clinical characteristics of infection/colonization due to carbapenemase-producing Enterobacterales in neonatal patients.

Authors:  Jiansheng Wang; Yuanpeng Lv; Weiwei Yang; Peng Zhao; Changfu Yin
Journal:  BMC Microbiol       Date:  2022-07-12       Impact factor: 4.465

Review 3.  Gastrointestinal Endoscopy-Associated Infections: Update on an Emerging Issue.

Authors:  Anasua Deb; Abhilash Perisetti; Hemant Goyal; Mark M Aloysius; Sonali Sachdeva; Dushyant Dahiya; Neil Sharma; Nirav Thosani
Journal:  Dig Dis Sci       Date:  2022-03-09       Impact factor: 3.487

4.  Rate and impact of duodenoscope contamination: A systematic review and meta-analysis.

Authors:  Sara Larsen; Rasmus Vinther Russell; Lotte Klinten Ockert; Stephen Spanos; Helena Strømstad Travis; Lars Holger Ehlers; Anders Mærkedahl
Journal:  EClinicalMedicine       Date:  2020-07-15

Review 5.  An update on gastrointestinal endoscopy-associated infections and their contributing factors.

Authors:  Charles Eugenio McCafferty; Marra Jai Aghajani; David Abi-Hanna; Iain Bruce Gosbell; Slade Owen Jensen
Journal:  Ann Clin Microbiol Antimicrob       Date:  2018-10-10       Impact factor: 3.944

Review 6.  Recent advances in understanding the epidemiology of healthcare-associated infections.

Authors:  Pranavi Sreeramoju
Journal:  F1000Res       Date:  2019-01-25

Review 7.  Use of ethylene-oxide gas sterilisation to terminate multidrug-resistant bacterial outbreaks linked to duodenoscopes.

Authors:  Lawrence F Muscarella
Journal:  BMJ Open Gastroenterol       Date:  2019-08-05

8.  Overestimated discriminatory power of MALDI-TOF mass spectrometry for typing of carbapenem-resistant Klebsiella pneumoniae clones.

Authors:  Fei Jiang; Ziyan Kong; Chen Cheng; Haiquan Kang; Bing Gu; Ping Ma
Journal:  Epidemiol Infect       Date:  2019-12-17       Impact factor: 2.451

Review 9.  Duodenoscope-associated infection prevention: A call for evidence-based decision making.

Authors:  Cori L Ofstead; Brandy L Buro; Krystina M Hopkins; John E Eiland; Harry P Wetzler; David R Lichtenstein
Journal:  Endosc Int Open       Date:  2020-11-17

Review 10.  Medical Device Sterilization and Reprocessing in the Era of Multidrug-Resistant (MDR) Bacteria: Issues and Regulatory Concepts.

Authors:  Jonathan Josephs-Spaulding; Om V Singh
Journal:  Front Med Technol       Date:  2021-02-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.