Literature DB >> 29567183

Simultaneous determination of isoproterenol, acetaminophen, folic acid, propranolol and caffeine using a sensor platform based on carbon black, graphene oxide, copper nanoparticles and PEDOT:PSS.

Ademar Wong1, Anderson Martin Santos1, Tiago Almeida Silva1, Orlando Fatibello-Filho2.   

Abstract

We explored the use of carbon black (CB), graphene oxide (GO), copper nanoparticles (CuNPs) and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) as electrode materials for the simultaneous determination of isoproterenol, acetaminophen, folic acid, propranolol and caffeine. The designed nanostructured surface was widely characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), contact angle measurements and electrochemistry. From electrochemical characterization assays carried out towards the potassium ferricyanide redox probe, fast electron transfer kinetics and a considerably higher electroactive surface area were observed for the modified electrodic surface based on CB, GO, CuNPs and PEDOT:PSS film. Using square-wave voltammetry (SWV), well defined and resolved anodic peaks were detected for isoproterenol, acetaminophen, folic acid, propranolol and caffeine, with peak-to-peak potential separation not less than 170 mV. Then, the SWV technique was explored for the simultaneous determination of quinary mixtures of these analytes, resulting in analytical curves with linear ranges and limits of detection at micromolar concentration levels. The practical viability of the proposed voltammetric sensor was illustrated in the analysis of human body fluid samples. The proposed sensor showed good repeatability and a successful application using urine and serum matrices, with recoveries close to 100%.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon black; Carbon-metal nanomaterials; Copper nanoparticles; Electroanalysis; Graphene oxide; Simultaneous sensing

Mesh:

Substances:

Year:  2018        PMID: 29567183     DOI: 10.1016/j.talanta.2018.02.066

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Nano optical and electrochemical sensors and biosensors for detection of narrow therapeutic index drugs.

Authors:  Omid Heydari Shayesteh; Reza Mahjub; Akram Ranjbar; Katayoun Derakhshandeh; Mahdi Jamshidi
Journal:  Mikrochim Acta       Date:  2021-11-06       Impact factor: 5.833

2.  Facile bimetallic co-amplified electrochemical sensor for folic acid sensing based on CoNPs and CuNPs.

Authors:  Zhen-Fan Zhou; Xiao-Zhen Feng; Tao Zhan; Guo-Cheng Han; Zhencheng Chen; Heinz-Bernhard Kraatz
Journal:  Anal Bioanal Chem       Date:  2022-08-05       Impact factor: 4.478

Review 3.  Graphene Oxide: A Smart (Starting) Material for Natural Methylxanthines Adsorption and Detection.

Authors:  Rita Petrucci; Isabella Chiarotto; Leonardo Mattiello; Daniele Passeri; Marco Rossi; Giuseppe Zollo; And Marta Feroci
Journal:  Molecules       Date:  2019-11-21       Impact factor: 4.411

4.  Spectroelectrochemical Determination of Isoprenaline in a Pharmaceutical Sample.

Authors:  Fabiola Olmo; Jesus Garoz-Ruiz; Julia Carazo; Alvaro Colina; Aranzazu Heras
Journal:  Sensors (Basel)       Date:  2020-09-11       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.