Literature DB >> 29567181

Electrochemical detection of c-reactive protein based on anthraquinone-labeled antibody using a screen-printed graphene electrode.

Sakda Jampasa1, Weena Siangproh2, Rawiwan Laocharoensuk3, Tirayut Vilaivan4, Orawon Chailapakul5.   

Abstract

In this present work, a novel electrochemical immunosensor employing a screen-printed graphene electrode (SPGE) for a simple and highly sensitive determination of C-reactive protein (CRP) in a sandwich-type format was proposed. The sensor comprised of two CRP-specific antibodies: an unlabeled capture primary antibody (Anti-1°Ab) and an electrochemically detectable anthraquinone-labeled signaling secondary (AQ-2°Ab) antibody. The Anti-1°Ab was first covalently anchored onto an L-cysteine/gold-modified disposable SPGE (L-Cys/Au/SPGE) to create the anti-CRP surface. After binding of the CRP and the AQ-2°Ab, the electrochemical signal response was measured using differential pulse voltammetry (DPV). In the presence of CRP, the sensor exhibited a significant increase in the AQ current at AQ-2°Ab compared to the negative control. The CRP concentration was detected in the range of 0.01-150 µg/mL, and the limit of detection (LOD) (S/N = 3) and limit of quantitation (LOQ) (10 SD/Slope) were 1.5 ng/mL and 10 ng/mL, respectively. This sensor exhibited very high sensitivity in determining CRP and was successfully applied to detect CRP in certified human serum with satisfactory results. The developed sensor is suitable as an alternative method for determination of CRP and the same principle may be further applied to determine other clinically important target molecules.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anthraquinone; C-reactive protein; Electrochemical sensors; Sandwich format; Signaling antibody

Mesh:

Substances:

Year:  2018        PMID: 29567181     DOI: 10.1016/j.talanta.2018.02.075

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  12 in total

1.  An origami paper-based electrochemical immunoassay for the C-reactive protein using a screen-printed carbon electrode modified with graphene and gold nanoparticles.

Authors:  Suchanat Boonkaew; Sudkate Chaiyo; Sakda Jampasa; Sirirat Rengpipat; Weena Siangproh; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2019-02-02       Impact factor: 5.833

2.  Disposable paper-based electrochemical sensor using thiol-terminated poly(2-methacryloyloxyethyl phosphorylcholine) for the label-free detection of C-reactive protein.

Authors:  Chanika Pinyorospathum; Sudkate Chaiyo; Pornpen Sae-Ung; Voravee P Hoven; Panittha Damsongsang; Weena Siangproh; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2019-06-26       Impact factor: 5.833

3.  Ultrasensitive fluorescent aptasensor for CRP detection based on the RNase H assisted DNA recycling signal amplification strategy.

Authors:  Zhongzhi Liu; Dan Luo; Fangling Ren; Fengying Ran; Wei Chen; Bingqiang Zhang; Ceming Wang; Hao Chen; Jian Wei; Qinhua Chen
Journal:  RSC Adv       Date:  2019-04-16       Impact factor: 4.036

4.  Impedimetric determination of cortisol using screen-printed electrode with aptamer-modified magnetic beads.

Authors:  Pannaporn Pusomjit; Prinjaporn Teengam; Nichanan Thepsuparungsikul; Sucharat Sanongkiet; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2021-01-15       Impact factor: 5.833

Review 5.  Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes.

Authors:  Beatriz Pérez-Fernández; Agustín Costa-García; Alfredo de la Escosura- Muñiz
Journal:  Biosensors (Basel)       Date:  2020-04-02

Review 6.  Electrochemical sensing: A prognostic tool in the fight against COVID-19.

Authors:  Sharda Kotru; Martin Klimuntowski; Hashim Ridha; Zakir Uddin; Ali A Askhar; Gurmit Singh; Matiar M R Howlader
Journal:  Trends Analyt Chem       Date:  2021-01-23       Impact factor: 14.908

7.  Fabrication of GQD-Electrodeposited Screen-Printed Carbon Electrodes for the Detection of the CRP Biomarker.

Authors:  Muthaiyan Lakshmanakumar; Noel Nesakumar; Swaminathan Sethuraman; Rajan K S; Uma Maheswari Krishnan; John Bosco Balaguru Rayappan
Journal:  ACS Omega       Date:  2021-11-22

8.  Development of a Magnetic Nanoparticles-Based Screen-Printed Electrodes (MNPs-SPEs) Biosensor for the Quantification of Ochratoxin A in Cereal and Feed Samples.

Authors:  Xian Zhang; Zuohuan Wang; Hui Xie; Renjie Sun; Tong Cao; Narayan Paudyal; Weihuan Fang; Houhui Song
Journal:  Toxins (Basel)       Date:  2018-08-06       Impact factor: 4.546

Review 9.  Antibody-Electroactive Probe Conjugates Based Electrochemical Immunosensors.

Authors:  Mateusz Kondzior; Iwona Grabowska
Journal:  Sensors (Basel)       Date:  2020-04-03       Impact factor: 3.576

10.  Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode.

Authors:  Somasekhar R Chinnadayyala; Jinsoo Park; Young Hyo Kim; Seong Hye Choi; Sang-Myung Lee; Won Woo Cho; Ga-Yeon Lee; Jae-Chul Pyun; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2019-12-16       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.