Literature DB >> 29549009

A Novel Objective Approach to the External Measurement of Pectus Excavatum Severity by Means of an Optical Device.

Francesca Uccheddu1, Marco Ghionzoli2, Yary Volpe1, Michaela Servi1, Rocco Furferi1, Lapo Governi1, Flavio Facchini2, Roberto Lo Piccolo2, Kathleen S McGreevy3, Alessandra Martin2, Monica Carfagni1, Antonio Messineo4.   

Abstract

BACKGROUND: Current approaches to quantifying the severity of pectus excavatum require internal measurements based on cross-sectional imaging. The aim of this study is to exploit a novel index evaluated on the external surface of the chest with a three-dimensional (3D) optical scanner.
METHODS: Fifty-one children (41 male, 10 female) between 2 and 17 years of age were evaluated with a 3D optical scanner. Pectus excavatum severity was calculated by using an ad hoc instant 3D scanner and defining an automatic procedure to generate an optical 3D correction index (CI3D). For the latter, an ideal threshold was derived from a statistical analysis, and five blind surveys were collected from pediatric specialists on chest wall deformities. The CI3D was then correlated with blind clinical assessments of PE severity.
RESULTS: The cutoff thresholds were determined to optimally discriminate between six degrees of severity of PE patients by a correlation analysis. The correlation coefficient obtained by matching the CI3D with the average subjective severity shows that the proposed method outperforms traditional approaches.
CONCLUSIONS: The optical 3D index has a good match with the average subjective assessment in distinguishing patients with mild to severe PE. This innovative approach offers several advantages over existing indices, as it is repeatable and does not require cross-sectional imaging. The index might be particularly suitable for monitoring the efficacy of nonoperative treatment and, in the future, for designing an optimal personalized usage of therapeutic devices.
Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 29549009     DOI: 10.1016/j.athoracsur.2018.02.024

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Analysis of chest wall elevation after the Nuss procedure using 3D body scanning technique in patients with pectus excavatum.

Authors:  Sadashige Uemura; Atsushi Yoshida; Hisako Kuyama
Journal:  Pediatr Surg Int       Date:  2021-03-19       Impact factor: 1.827

2.  BROAD PECTUS EXCAVATUM TREATMENT: LONG TERM RESULTS OF A BRAZILIAN TECHNIQUE.

Authors:  Davi de Podestá Haje; Sydney Abrão Haje; José Batista Volpon; Ana Carolina Oliveira da Silva; Leonardo Ferreira Braz Lima; Wilson Huang
Journal:  Acta Ortop Bras       Date:  2021 Jul-Aug       Impact factor: 0.513

3.  Optical imaging versus CT and plain radiography to quantify pectus severity: a systematic review and meta-analysis.

Authors:  Jean H T Daemen; Tom G J Loonen; Pieter W J Lozekoot; Jos G Maessen; Thomas J J Maal; Karel W E Hulsewé; Yvonne L J Vissers; Erik R de Loos
Journal:  J Thorac Dis       Date:  2020-04       Impact factor: 2.895

  3 in total