Literature DB >> 29526600

Five-year minimum clinical and radiographic outcomes of total shoulder arthroplasty using a hybrid glenoid component with a central porous titanium post.

Clay G Nelson1, Tyler J Brolin1, Marcus C Ford1, Richard A Smith1, Frederick M Azar1, Thomas W Throckmorton2.   

Abstract

BACKGROUND: To determine the effectiveness of hybrid glenoid components in reducing the frequency of glenoid component loosening, we evaluated clinical and radiographic outcomes at a minimum 5-year follow-up in 45 shoulders that underwent total shoulder arthroplasty (TSA) using a system with a central porous titanium post to augment the cemented peripheral pegs.
METHODS: Function and pain were evaluated with the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment score, visual analog scale, active shoulder range of motion, and strength. Postoperative radiographs were analyzed for radiolucent lines, progressive loosening, and at-risk signs.
RESULTS: The mean American Shoulder and Elbow Surgeons score improved from 40.4 to 83.7 (P < .0001) and the mean visual analog scale from 5.9 to 0.8 (P < .0001). Forward elevation improved from 113° to 151° (P < .001), internal rotation from 49° to 60° (P = .035), and mean external rotation from 36° to 50° (P = .0006). Radiographs showed glenoid component radiolucency in 29 shoulders. Radiolucencies were confined to the area under the glenoid faceplate in 6 and were only around the central post in 13. Nine TSAs (20%) demonstrated 2 or more columns of involvement but were not judged to be at-risk. One implant (2.2%) had glenoid component failure and was revised to a hemiarthroplasty.
CONCLUSION: Anatomic TSA using a hybrid glenoid component with a central porous titanium post demonstrated a low rate of mechanical failure and a rate of radiolucent lines comparable to reports of all polyethylene implants. Further evaluations are needed to demonstrate the long-term durability of these implants and to determine the significance and fate of the radiolucent lines, particularly relative to the central post.
Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  5-year follow-up; Total shoulder arthroplasty; central porous titanium post; glenoid component loosening; hybrid glenoid component; radiographic outcomes

Mesh:

Substances:

Year:  2018        PMID: 29526600     DOI: 10.1016/j.jse.2018.01.012

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  8 in total

1.  One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers.

Authors:  Frederick A Matsen; Joseph P Iannotti; R Sean Churchill; Lieven De Wilde; T Bradley Edwards; Matthew C Evans; Edward V Fehringer; Gordon I Groh; James D Kelly; Christopher M Kilian; Giovanni Merolla; Tom R Norris; Giuseppe Porcellini; Edwin E Spencer; Anne Vidil; Michael A Wirth; Stacy M Russ; Moni Neradilek; Jeremy S Somerson
Journal:  Int Orthop       Date:  2018-12-03       Impact factor: 3.075

2.  [Interpretation of 2020 American Academy of Orthopaedic Surgeons (AAOS) on the Management of Glenohumeral Joint Osteoarthritis Evidence-Based Clinical Practice Guideline].

Authors:  Xianxiang Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-11-15

3.  Radiographic and clinical outcomes of second generation Trabecular Metal™ glenoid components in total shoulder arthroplasty.

Authors:  Raymond E Chen; Alexander M Brown; Alexander S Greenstein; Sandeep Mannava; Ilya Voloshin
Journal:  Shoulder Elbow       Date:  2020-03-24

4.  Hybrid Glenoid Designs in Anatomic Total Shoulder Arthroplasty: A Systematic Review.

Authors:  Ahmed Haleem; Phelopater Sedrak; Chetan Gohal; George S Athwal; Moin Khan; Bashar Alolabi
Journal:  HSS J       Date:  2021-09-03

5.  Articular surface failure in hybrid anatomic glenoid components: a unique failure mechanism.

Authors:  Joseph G Monir; William K Powers; Joseph J King; Thomas W Wright; Bradley S Schoch
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-06-15

6.  Extra-short humeral heads reduce glenohumeral joint overstuffing compared with short heads in anatomic total shoulder arthroplasty.

Authors:  Joseph G Monir; Kevin A Hao; Dilhan Abeyewardene; Kevin J O'Keefe; Joseph J King; Thomas W Wright; Bradley S Schoch
Journal:  JSES Int       Date:  2021-12-22

7.  The effect of radial mismatch on radiographic glenoid loosening.

Authors:  Bradley S Schoch; Thomas W Wright; Joseph D Zuckerman; Pierre-Henri Flurin; Charlotte Bolch; Chris P Roche; Joseph J King
Journal:  JSES Open Access       Date:  2019-11-18

8.  Humeral stem lucencies correlate with clinical outcomes in anatomic total shoulder arthroplasty.

Authors:  Gregory Y LaChaud; Bradley S Schoch; Thomas W Wright; Chris Roche; Pierre H Flurin; Joseph D Zuckerman; Joseph J King
Journal:  JSES Int       Date:  2020-05-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.