Literature DB >> 2952175

The relationship between narrow and wide bandwidth filter settings during an EMG scanning procedure.

J R Cram, A Garber.   

Abstract

This study examined the correlation between EMG values measured with wide (25-1000 Hz) and narrow (100-200 Hz) band-width filters. An EMG diagnostic scan was conducted on 32 chronic pain patients admitted to an inpatient treatment unit. EMG readings were taken from a total of 44 sites (11 sites X 2 sides X 2 postures). Each EMG measure was passed in parallel through a narrow and wide band-pass filter and the stable readings were recorded. Correlated t tests and Pearson correlations were used to compare the data from the narrow and wide filter settings. The measures from the wide filter were significantly higher than the measures from the narrow filter. In addition, 61% of the correlations were greater than .90. The majority of the correlations below the median (.93) occurred in the neck region and the abdomen. The implications of the findings are discussed.

Entities:  

Mesh:

Year:  1986        PMID: 2952175     DOI: 10.1007/bf00999978

Source DB:  PubMed          Journal:  Biofeedback Self Regul        ISSN: 0363-3586


  8 in total

1.  Wave analyses of tissue noise and muscle action potentials.

Authors:  K J HAYES
Journal:  J Appl Physiol       Date:  1960-07       Impact factor: 3.531

2.  Action potential parameters in normal human muscle and their physiological determinants.

Authors:  F BUCHTHAL; P PINELL; P ROSENFALCK
Journal:  Acta Physiol Scand       Date:  1954-11

3.  Myo-electric energy spectra.

Authors:  R N Scott
Journal:  Med Biol Eng       Date:  1967-05

4.  Physiology and mathematics of myoelectric signals.

Authors:  C J De Luca
Journal:  IEEE Trans Biomed Eng       Date:  1979-06       Impact factor: 4.538

5.  Muscular fatigue and action potential conduction velocity changes studied with frequency analysis of EMG signals.

Authors:  L Lindstrom; R Magnusson; I Petersén
Journal:  Electromyography       Date:  1970 Nov-Dec

6.  Myoelectric signal processing: optimal estimation applied to electromyography--Part II: experimental demonstration of optimal myoprocessor performance.

Authors:  N Hogan; R W Mann
Journal:  IEEE Trans Biomed Eng       Date:  1980-07       Impact factor: 4.538

7.  Muscle fatigue monitor: a noninvasive device for observing localized muscular fatigue.

Authors:  F B Stulen; C J De Luca
Journal:  IEEE Trans Biomed Eng       Date:  1982-12       Impact factor: 4.538

8.  EMG scanning in the diagnosis of chronic pain.

Authors:  J R Cram; J C Steger
Journal:  Biofeedback Self Regul       Date:  1983-06
  8 in total
  3 in total

Review 1.  Frequency characteristics of signals and instrumentation: implication for EMG biofeedback studies.

Authors:  P A Mathieu; S J Sullivan
Journal:  Biofeedback Self Regul       Date:  1990-12

2.  EMG muscle scanning: comparison to attached surface electrodes.

Authors:  J M Thompson; T J Madson; R P Erickson
Journal:  Biofeedback Self Regul       Date:  1991-06

3.  Yawning: a possible confounding variable in EMG biofeedback studies.

Authors:  R E Oman; S J Sullivan; J Fleury; E Dutil
Journal:  Biofeedback Self Regul       Date:  1989-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.