Literature DB >> 29517577

Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT.

Trine B Andersen1, Ramune Aleksyniene1, Søren K Boldsen2, Michael Gade1, Henrik Bertelsen1, Lars J Petersen1,3.   

Abstract

OBJECTIVE: The aim of this study was to investigate the contribution of contrast-enhanced computed tomography (CE-CT) to the localization of parathyroid adenomas compared with the dual-phase Tc-99m MIBI SPECT with low-dose CT (LD-CT). PATIENTS AND METHODS: This retrospective study included consecutive patients with primary hyperparathyroidism who underwent a preoperative dual-phase MIBI SPECT/CT followed by surgical resection. The standard of care was dual-phase MIBI SPECT/CT, acquired with LD-CT in the early phase and CE-CT in the late phase (SPECT/CE-CT). The presence and localization of positive sites were extracted from study reports. To examine the role of CE-CT, patient cases were independently re-reviewed, with the early LD-CT fused with early and late SPECT (SPECT/LD-CT). The two SPECT/CT methods were compared for sensitivity, and the positive predictive value and histopathology were used as a reference.
RESULTS: In total, 138 patients were included. The investigation was positive for suspected adenomas in 124 patients using SPECT/CE-CT and in 122 patients using SPECT/LD-CT. The per-patient sensitivity was 87.5% [95% confidence interval (CI): 80.7-92.6%] for SPECT/CE-CT and was not statistically significantly different from SPECT/LD-CT (85.3%; 95% CI: 78.2-90.8%) (P=0.39). The positive predictive value was 95.2% (95% CI: 95.4-99.9%) with SPECT/CE-CT versus 100% (95% CI: 96.8-100%) with SPECT/LD-CT. For small adenomas (≤500 mg), the sensitivity was low with SPECT/CE-CT (67%) as well as with SPECT/LD-CT (64%).
CONCLUSION: Late CE-CT, compared with late LD-CT, did not significantly improve the sensitivity of dual-phase Tc-99m MIBI parathyroid SPECT/CT in a population of patients with primary hyperparathyroidism. These findings were consistent regardless of the size, location, or histology of the adenomas.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29517577     DOI: 10.1097/MNM.0000000000000818

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  1 in total

1.  Factors That Affect the Sensitivity of Imaging Modalities in Primary Hyperparathyroidism.

Authors:  Minting Zhu; Yang He; Tingting Liu; Bei Tao; Weiwei Zhan; Yifan Zhang; Jing Xie; Xi Chen; Hongyan Zhao; Lihao Sun; Jianmin Liu
Journal:  Int J Endocrinol       Date:  2021-02-20       Impact factor: 3.257

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.