Posterior Capsule Opacification and Nd-YAG rates evaluation in a large series of pseudophakic cases.

Ioana Madalina Iliescu1, Maria Alexandra Constantin1, Cristina Cozma1, Ozana Manuela Moraru1, Cristian Mircea Moraru1.   

Abstract

PURPOSE: To evaluate the influence of Intraocular Lens (IOL) material and design on Posterior Capsule Opacification (PCO) and Neodymium-YAG (Nd-YAG) rates in eyes implanted with different Posterior Chamber Intraocular Lenses (PC IOLs) designs at the end of uncomplicated cataract surgeries.
SETTING: Oculus Eye Clinic, Bucharest, Romania.
DESIGN: Retrospective, observational study.
METHODS: This study comprised 4805 eyes operated for cataract in 2012 and 2013 with a post-operative average follow up of 40 ± 6,15 months (27-54 months). The PCO and Nd-YAG rates were recorded and compared among different IOL materials and designs and among different pathology groups.
RESULTS: From 4805 IOLs implanted, 2560 (53,27%) were hydrophilic and 2245 (45,73%) hydrophobic, 2937 (61%) were aspherical and 1868 (39%) spherical. We found statistical significant differences in the PCO and Nd-YAG rates between hydrophilic (18% and 14% respectively) and hydrophobic lenses (4% and 2% respectively) (p<0.0001). There were also statistically significant differences in the sub-group of hydrophilic aspheric IOLs, finding lower PCO and Nd:YAG rates with the C-loop haptics configuration (12,6% and 3,3% respectively) compared with the broad optic/ haptic junction (29,75% and 24,73% respectively) (p<0.001). No statistically significant differences on PCO and Nd:YAG rates were found for the different associated pathologies (p>0.05).
CONCLUSIONS: Hydrophilic lenses showed statistically higher PCO and Nd:YAG rates than hydrophobic lenses. In contrast, the optic asphericity and the associated pathologies had no influence on the PCO and Nd:YAG rates. IOL design and material seem to be the main characteristics influencing PCO and Nd-YAG rates. ABBREVIATIONS: LECs = lens epithelial cells.

Entities:  

Keywords:  IOL design; IOL material; Nd-Yag rates; posterior capsule opacification

Mesh:

Substances:

Year:  2017        PMID: 29516046      PMCID: PMC5827143     

Source DB:  PubMed          Journal:  Rom J Ophthalmol        ISSN: 2457-4325


Introduction

Cataract is a common and significant cause of visual impairment []. During surgery, it is impossible to mechanically remove all lens epithelial cells (LECs) from the capsular bag. The remaining equatorial LECs will migrate, undergo metaplasia, and form posterior capsule opacification (PCO). PCO causes light scatter within the visual axis and produce visual disability []. PCO is considered the most common reason for reduced visual acuity after cataract surgery in otherwise healthy eyes []. PCO also degrades various aspects of visual function, including contrast sensitivity [-], glare disability [-], color vision and stereoscopic vision []. The treatment for PCO is Neodymium:YAG (Nd:YAG) laser capsulotomy which, although considered safe, may lead to some complications, including intraocular lens (IOL) damage, intraocular pressure (IOP) elevation, cystoid macular edema or retinal detachment []. Studies have shown a correlation between PCO rates and IOL characteristics, such as edge design [] and optic material [,]. Also, creating a conti bnuous, centered and perfect sized anterior capsulorhexis can influence PCO occurrence []. In our study, we objectively quantified and compared PCO and Nd-YAG rates for all Posterior Chamber (PC) IOLs implanted in eyes operated for cataract in 2012 and 2013 in Oculus Eye Clinic, Bucharest. We recorded the PCO and Nd:YAG rates for hydrophilic/ hydrophobic and spherical/ aspherical IOL groups and evaluated the influence of IOLs characteristics on PCO and Nd:YAG rates. We also evaluated all the ocular and nonocular concurent pathology and their influence on PCO rates.

Methods

Patients with uneventful cataract surgeries and no postoperative complications who were operated in 2012 and 2013 at the Oculus Eye Clinic, Bucharest, Romania, were included in this retrospective observational clinical trial. The study was approved by the Ethics Committee, Oculus Eye Clinic, Bucharest (02/ 2016) and registered with the Romanian National Agency of Drugs and Medical Devices. Our study is in agreement with “human and animal rights” and respects the Helsinki Declaration of 1975 revised in 2000 and 2008. Patients’ charts were included in the study after examining all surgeries reports and postoperative information stored in the 2012-2013 Oculus Registry and only the charts that complied with the inclusion/ exclusion criteria were selected. The inclusion criterion was all uncomplicated eyes operated for cataract from January 2012 to December 2013. Exclusion criteria were eyes with ocular preoperative associated inflammatory pathology (uveitis) or trauma, complicated intraoperative cases with posterior capsular rupture, complicated postoperative cases: endophthalmitis, inflammation of different etiology of anterior or posterior pole or those with no follow-up visits. All surgeries were performed under topical anesthesia by five surgeons using ultrasound technology (INFINITI® Vision System, Stellaris PC or CENTURION® Vision System) followed by the polishing of the posterior capsule and the implantation of it in the bag PC IOL (of in the bag- without it). A small percentage (1.19%) of eyes had a capsular tension ring implanted addressing the zonular laxity. Few surgeries (1%) were followed by same session intravitreal injection of either Bevacizumab or Triamcinolone Acetonide for Diabetic Macular Edema (DME) or wet Age Related Macular Degeneration (AMD). Some surgeries (3,5%) were performed by using the femtolaser technology (LenSx® Laser System). Each patient received a PC IOL spherical or aspheric, hydrophilic or hydrophobic. All the patients received the same postoperative treatment: antibiotic and steroid fixed combination five times a day for two weeks, followed by steroid drops three times a day for another two weeks. The follow-up examinations were at first day, first month, and 3 months to one year postoperative, depending on ocular status. Further examinations (at every 3, 6 or 12 months) up to over 4 years (max 54 months) of follow-up were scheduled dictated by ocular features, referring the doctors’ requests or the patients’ visual complaints/ demands. The best distance and near corrected visual acuity (VA), anterior and posterior segment dilated slip lamp examination and tonometry were evaluated at each follow-up visit. The PCO was evaluated subjectively with the retro illumination of the slit lamp. PCO was considered when Elschnig’ Pearls or fibrosis could be noticed on the posterior capsule correspondent to the capsulorhexis opening. Nd:YAG laser treatment was performed when BDCVA decreased at least 20% due to PCO occurrence. PCO and Nd:YAG rates were evaluated for the different IOL material and design groups included in the present study. Additionally, cases were assigned into different pathology groups and the PCO rates were recorded accordingly to the ocular or non-ocular pathologies. Statistical analysis Statistical analyses were computed with SPSS for Windows software (version 18.0, SPSS, Inc.) and Pearson Chi-Square test was applied when comparing rates for hydrophilic/ hydrophobic, spherical/ aspheric IOLs. Statistical significance was considered when p<0.05.

Results

The current study comprised 4805 eyes from 3494 patients with a mean follow-up of 40 ± 6.15 months (range from 27 to 54 months). There were 1810 (38%) males and 2995 (62%) females. The mean age at the last follow-up was 73 ± 12 years (range 21 to 98 years) with 80% of the patients between 60 to 90 years old. The patient age distribution is plotted in . Patient age distribution All IOLs implanted during 2012 and 2013 at the Oculus Eye Clinic in Bucharest were included in the present study. shows the IOLs evaluated and their pertinent characteristics. A total of 4805 IOLs were implanted, of which: 2937 (61%) aspherical, 1868 (39%) spherical, 2560 (53.27%) hydrophilic and 2245 (45.73%) hydrophobic. Type of lenses implanted and their characteristics The mean PCO and Nd-YAG rates for the hydrophilic group were 18% and 14%, respectively and for the hydrophobic group, they were 4% and 2%, respectively, finding a statistical significant difference between both groups (p<0.0001). We also found a statistical significant difference between the Nd-YAG rates of the spherical (3.8%) and aspheric lenses (10%) (p=0.000), but these spherical/ aspheric lenses groups showed large differences in the distribution of the lens types. We further divided these two large groups in sub-groups following material and lens optic/ haptic design. The distribution of lenses in these sub-groups with their PCO and Nd-YAG Rates are shown in . No statistically significant differences were found between hydrophobic aspheric (C-Loop) and hydrophobic spherical IOLs (C-Loop) for PCO (p>0.05) and Nd:YAG rates (p>0.05). Regarding the hydrophilic IOL group, there were statistical significant differences between aspheric and spherical IOLs for PCO (p<0.0001) and Nd:YAG rates (p<0.0001). However, in the sub-group of hydrophilic aspheric IOLs, 89% of the lenses had a broad optic/ haptic junction and only 11% a C-Loop design in contrast to the C-loop haptic configuration found in all hydrophilic spherical lenses. The subgroup of lenses with their Posterior Capsule Opacification (PCO) and Nd-YAG rates Analyzing the PCO and Nd:YAG rates for the sub-group of hydrophilic aspheric IOLs with different haptics configuration, we found statistically significant differences (p<0.001) for the PCO and Nd:YAG rates between the group of IOLs with broad optic/ haptic junction (29.75% and 24.73% rates, respectively) and C-Loop haptics (12.6% and 3.3%, respectively). In contrast, comparing the PCO and Nd:YAG rates of the hydrophilic aspheric sub-group with C-loop configuration (12.6% and 3.3%, respectively) versus the hydrophilic spherical sub-group with the same haptics configuration (7.64% and 5.1% rates, respectively), no statistically significant differences were found (p>0.05). The study also followed concurrent ocular and general pathology and their influence on PCO and Nd-YAG rates. shows the distribution of patients for each pathology group. Distribution of patients for each pathology group shows the PCO rates for each pathology group with the additional information of the percentage of hydrophilic lenses per group. There were no statistically significant correlations between the ocular associated pathologies and PCO rates (p>0.05). PCO rate for each pathology group

Conclusions

In the current study, a total of 4805 implanted IOLs were evaluated. The incidence of the PCO and Nd:YAG rates were assessed after a mean of 40±6.15 months of follow up (from 27 to 54 months). The analysis showed that PCO and Nd:YAG rates were statistically significantly higher in those eyes implanted with hydrophilic IOLs than with hydrophobic IOLs. Therefore, IOL material seems to be a determinant factor for PCO occurrence and need of Nd-YAG laser treatment after uneventful cataract surgery. Our results were in accordance with several studies that have shown a correlation between PCO rates and optic material [,]. Hydrophilic IOLs have been associated with higher rates of PCO than hydrophobic IOLs [,]. Regarding the IOL characteristics/ material, many studies comparing square-edged hydrophobic and hydrophilic acrylic IOLs [-] have shown that hydrophilic IOLs perform less favorably than hydrophobic IOLs in terms of PCO prevention. Regarding the IOL asphericity, we did not find any significant correlation for PCO and Nd:YAG occurrence. Besides, that hydrophilic aspheric IOLs sub-group showed statistically significant higher PCO and Nd:YAG rates than hydrophilic spherical IOLs, these results being mainly attributed to the fact that in the sub-group of hydrophilic aspheric IOLs, 89% of the lenses had a broad optic/ haptic junction with high PCO and Nd-YAG rates and only 11% showed a C-Loop design in contrast to the C-loop haptic configuration found in all hydrophilic spherical lenses. Our statistical analysis confirmed that, for the hydrophilic lenses, we found significantly higher PCO and Nd:YAG rates for the IOLs with the broad optic-haptic junction than for those with the C-loop configuration without any correlation to the asphericity. In contrast, when we compared the PCO and Nd:YAG rates of the hydrophilic aspheric sub-group with C-loop configuration (12.6% and 3.3%, respectively) versus the hydrophilic spherical sub-group with the same haptics configuration (7.64% and 5.1% rates, respectively), no statistically significant differences were found (p>0.05). The broad gap in the squared-edged barrier at the broad optic–haptic junction of an IOL has been described as the Achilles heel in PCO prevention as it provides a point of migration for LECs from the equatorial region of the capsule onto the central posterior capsule []. We noticed a lot of variability in PCO and Nd:YAG rates among the different hydrophilic IOL models evaluated. These differences might be due to the differences in the haptics and edges design. In contrast, regarding to the hydrophobic IOLs group, all the lenses showed very similar PCO and Nd:YAG rates, with very similar IOL design characteristics. Concerning the different pathology groups, our study found no statistically significant correlations between the ocular associated pathologies and PCO rates (p>0.05). Being a retrospective analysis conducted on a large number of eyes, this study had some limitations. One limitation was that the groups of IOLs formed by model were not equal in size and the distribution of IOLs among different pathology groups was not the same. Another limitation was the use of the CTR or Femtolaser in some particular cases or some intravitreal injections done at the end of the surgeries. Despite the minimal limitations, our study had many strong points. We managed to include a large sample of eyes with a high diversity of IOLs implanted and we followed these eyes for a long period of time. Being also able to perform Nd-YAG laser treatment on site, all our patients who developed PCO and needed to be treated, could come to the clinic and receive proper care. Our study also showed that not only the material of the IOL was a determinant factor for PCO formation, but also the design of the optic/ haptic. The C-Loop design performed statistically better in terms of PCO prevention compared to the broad optic/ haptic junction configuration despite same hydrophilic material and similar edges configuration. Our analysis led to the additional conclusion that asphericity or co-existing ocular or non-ocular pathology did not influence the PCO occurrence. Acknowledgments: Dr. Iliescu, Constantin and Cozma were supported by a research Grant from Alcon Laboratories, Inc. (Alcon Romania S.R.L., located at 301-311 Barbu Văcărescu Blvd., Lake View Building, 5th floor, district 2, Bucharest, Romania, IIT Grant No. 20949341). No authors have any financial interest in a product, method, or material presented in the article. The article was presented in the following meetings: IIIrd Congress of the Romanian Society of Cataract and Refractive Surgery - Eforie Nord, Romania, 23-26 June 2016; The XXXIV Congress of the European Society of Cataract and Refractive Surgeons- Copenhagen, Denmark, 10-14 Sept 2016; XVth National Congress of the Romanian Society of Ophthalmology – Sinaia, Romania, 5-8 October 2016.
Table 1

Type of lenses implanted and their characteristics

LENS TYPE%No of casesManufacturerMaterialDesignHaptic angulationOptics
Acri.Tec 47LC1%7Acri. Tec Hydrophilic with cover 1 piece with loops Plate haptics Aspheric
Acri.Tec 47S4%17Acri. Tec Hydrophilic with cover 1 piece with loops Plate haptics Spherical
Adapt-AO4%210B&L Hydrophilic 1 piece Square-edges One-piece 4 closed loops 0° angulation Aspheric aberration -free
Akreos- Adapt1%6B&L Hydrophilic 1 piece Square-edges One-piece 4 closed loops 0° angulation Spherical
Aspheric Ophtec02%1Ophtec BV Hydrophobic 1 piece with loops 2 closed loops 5° Aspheric
Bioline Yellow6%273iMedical Hydrophilic 1-piece square edges C-loops 0° Spherical
B-Lens2%108Hanita Hydrophilic 1-piece square edges C -loops 5° Spherical
CT 47LC2%96Zeiss Hydrophilic1-piece square edges C-loops 0° Aspheric
CT 47S9%430Zeiss Hydrophilic1-piece square edges C-loops 0° Spherical
CT Xtreme D04%2Zeiss Hydrophilic1-piece square edges C-loops 0° Spherical
Dr Schmidt4%19HumanOptics Hydrophilic1-piece square edges C Haptic 0° Spherical
MA60AC4%17Alcon Hydrophobic 3-pieces sharp-edges C-loops 10° Spherical
MA60MA1%69Alcon Hydrophobic 3-pieces sharp-edges C-loops 5° Spherical
MC60T02%1Hydrophobic
MI6017%829B&L Hydrophilic 1-piece 4 haptics Slender 8° Aspheric
MJ 144%21B&L Hydrophilic 1-piece sharp edges 4 haptics Slender 8° Aspheric
MX603%124B&L Hydrophobic 1-piece post square edges Modified C Aspheric
MX60T1%54B&L Hydrophobic 1-piece post square edges Modified C Aspheric Toric
Ophtec Monomax PC5506%299Ophtec BV Hydrophilic1-piece post square edges C-loop 5° Spherical
RAFI FOLDABLES1%51RAFI Systems Inc Hydrophilic 1-piece square edges C-loop 0° Spherical
SA60AT7%344Alcon Hydrophobic 1-piece square edges C-loop 0° Spherical
SeeLens4%191Hanita Hydrophilic 1-piece square edges C-loop 5° Spherical
SN60AT1%41Alcon Hydrophobic 1-piece square edges C-loop 0° Spherical
SN60WF22%1080Alcon Hydrophobic 1-piece square edges C-loop 0° Aspheric
SN6AD15%256Alcon Hydrophobic 1-piece square edges C-loop 0° Aspheric multifocal
SN6ATx5%252Alcon Hydrophobic 1-piece square edges C-loop 0° Aspheric Toric
SND1TX12%6Alcon Hydrophobic 1-piece square edges C-loop 0° Aspheric multifocal Toric
XLSTABI SKI02%1Zeiss Hydrophilic1-piece square edges 10°Aspheric
Total100%4805
Table 2

The subgroup of lenses with their Posterior Capsule Opacification (PCO) and Nd-YAG rates

TYPE OF LENSESNo (% of total)SUBTYPENo (% of total)PCO RateNd-YAG Rate Haptic ConfigurationPCO RateNd-Yag Rate
SPHERICAL LENSES2937 (61%)HYDROPHILIC1164 (39.6%)27.68%22.3%Broad optic/ haptic junction (89%)29.75%24.73%
C-Loop (11%)12.6%3.3%
HYDROPHOBIC1773 (60.4%) 4.02%2%C-Loop (100%) 4.02%2%
1868 (39%)HYDROPHILIC1396 (74.73%) 7.64%5.1%C-Loop (100%) 7.64%5.1%
HYDROPHOBIC472 (25.27%) 5.29%1.9%C-Loop (100%) 5.29%1.9%
Table 3

Distribution of patients for each pathology group

OCULAR PATHOLOGYGENERAL PATHOLOGY
Age Related Macular Degeneration 21% (n=992)Type II Diabetes 15% (n=734)Oral medication 69%No Diabetic Retinopathy 80%
Background Diabetic Retinopathy 16%
Glaucoma 14% (n=656)Insulin 17% Proliferative Diabetic Retinopathy 3%
Pseudoexfoliative Syndrome 8% (n=370)Diet 14% Diabetic Maculopathy 1%
Intravitreal Injections 1% (n=40)General Cortisone Treatment ~1% (n=59)
Table 4

PCO rate for each pathology group

PATHOLOGYRate of PCO
Diabetes (n=734) 6% (n=46) - 47% hydrophilic lenses
Age Related Macular Degeneration (n=992) 12% (n=123) - 62% hydrophilic lenses
Glaucoma (n=656) 16% (n=108) - 55% hydrophilic lenses
Pseudoexfoliation Syndrome (n=370) 12% (n=45) - 68% hydrophilic lenses
General Cortisone treatment (n=59) 2% (n=1) - 23% hydrophilic lenses
  21 in total

1.  Correlation between posterior capsule opacification and visual function before and after Neodymium: YAG laser posterior capsulotomy.

Authors:  Ken Hayashi; Hideyuki Hayashi; Fuminori Nakao; Fumihiko Hayashi
Journal:  Am J Ophthalmol       Date:  2003-10       Impact factor: 5.258

2.  Adverse clinical consequences of neodymium:YAG laser treatment of posterior capsule opacification.

Authors:  Christian Billotte; Gilles Berdeaux
Journal:  J Cataract Refract Surg       Date:  2004-10       Impact factor: 3.351

3.  Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-piece acrylic intraocular lenses.

Authors:  Catherine J Heatley; David J Spalton; Anupma Kumar; Romina Jose; James Boyce; Lloyd E Bender
Journal:  J Cataract Refract Surg       Date:  2005-04       Impact factor: 3.351

4.  Association between intensity of posterior capsule opacification and contrast sensitivity.

Authors:  Wolf Buehl; Stefan Sacu; Oliver Findl
Journal:  Am J Ophthalmol       Date:  2005-11       Impact factor: 5.258

Review 5.  Effect of intraocular lens design on posterior capsule opacification.

Authors:  Wolf Buehl; Oliver Findl
Journal:  J Cataract Refract Surg       Date:  2008-11       Impact factor: 3.351

6.  Glare measurements before and after neodymium-YAG laser posterior capsulotomy.

Authors:  R W Knighton; A R Slomovic; R K Parrish
Journal:  Am J Ophthalmol       Date:  1985-11-15       Impact factor: 5.258

7.  The effect of polymethylmethacrylate and acrysof intraocular lenses on the posterior capsule in patients with a large capsulorrhexis.

Authors:  W R Meacock; D J Spalton; E J Hollick; S Barman; J F Boyce
Journal:  Jpn J Ophthalmol       Date:  2001 Jul-Aug       Impact factor: 2.447

8.  Evaluation of visual function following neodymium:YAG laser posterior capsulotomy.

Authors:  B V Magno; M B Datiles; M S Lasa; M R Fajardo; R C Caruso; M I Kaiser-Kupfer
Journal:  Ophthalmology       Date:  1997-08       Impact factor: 12.079

9.  Functional visual acuity after neodymium:YAG laser capsulotomy in patients with posterior capsule opacification and good visual acuity preoperatively.

Authors:  Tais Hitomi Wakamatsu; Takefumi Yamaguchi; Kazuno Negishi; Minako Kaido; Yukihiro Matsumoto; Reiko Ishida; Takashi Kojima; Osama Mohamed Aly Ibrahim; Megumi Saiki; Murat Dogru; Kazuo Tsubota
Journal:  J Cataract Refract Surg       Date:  2011-02       Impact factor: 3.351

10.  [Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: data of one-year prospective clinical study].

Authors:  Reda Zemaitiene; Martynas Speckauskas; Brigita Glebauskiene; Vytautas Jasinskas
Journal:  Medicina (Kaunas)       Date:  2008       Impact factor: 2.430

View more
  2 in total

1.  Posterior capsular opacification comparison between morphology and objective visual function.

Authors:  Chengzhe Lu; Shasha Yu; Hui Song; Yun Zhao; Shiyong Xie; Xin Tang; Xiaoyong Yuan
Journal:  BMC Ophthalmol       Date:  2019-02-04       Impact factor: 2.209

2.  Nd:YAG Capsulotomy Rates with Two Multifocal Intraocular Lenses.

Authors:  Huiran Bai; Honglei Li; Simeng Zheng; Lihong Sun; Xiaoming Wu
Journal:  Int J Gen Med       Date:  2021-11-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.