[Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: data of one-year prospective clinical study].

Reda Zemaitiene1, Martynas Speckauskas, Brigita Glebauskiene, Vytautas Jasinskas.   

Abstract

OBJECTIVE: To evaluate and compare the impact of two sharp-edge optic foldable intraocular lenses (IOLs) of similar design made from different material (hydrophilic acrylic or hydrophobic acrylic) on visual function, anterior and posterior capsule opacification at one-year follow-up after cataract phacoemulsification.
MATERIAL AND METHODS: Seventy-two eyes of 72 patients scheduled for cataract surgery were included in a prospective clinical study. Two foldable sharp-edge optic posterior chamber acrylic IOLs of similar design were used. Thirty-nine eyes of 39 patients received a single-piece hydrophilic acrylic (PC 511, Ophtec) IOL and 33 eyes of 33 patients - single-piece hydrophobic acrylic (AcrySof, SA60AT, Alcon) IOL. Visual acuity, anterior capsule opacification (ACO), capsulorrhexis/optic overlapping, and posterior capsule opacification (PCO) were evaluated. The intensity of ACO was assessed subjectively. PCO values in the entire IOL optic area and in the central 3-mm optic zone were assessed using a photographic image analysis system (EPCO 2000). The patients were examined at one year postoperatively.
RESULTS: There were no significant differences in best-corrected visual acuity and capsulorrhexis/optic overlapping between IOL types at 1-year follow-up after surgery. In the single-piece hydrophilic acrylic IOL group, the grade of ACO density was significantly higher in capsulorrhexis rim area (1.56+/-0.71 and 1.00+/-0.75) and in the capsule/optic area (1.62+/-0.67 and 1.00+/-0.75) (P<0.05). PCO values of the entire IOL optic area (0.12+/-0.13 and 0.024+/-0.02) as well as in the central 3-mm optic zone (0.06+/-0.11 and 0.001+/-0.003) was significantly higher in the single-piece hydrophilic acrylic IOL group one year postoperatively (P<0.05). In 33.3% of cases of the single-piece hydrophilic acrylic IOL group, contraction of haptics to IOL optics was present one year postoperatively, which was not present in any case of the single-piece hydrophobic acrylic IOL group.
CONCLUSIONS: One-year follow-up after cataract surgery has shown a significant difference in ACO and PCO development comparing single-piece hydrophilic acrylic and single-piece hydrophobic acrylic intraocular lenses. The effect of hydrophobic acrylic foldable lenses on preventing anterior and posterior capsule opacification is mainly a result of the acrylic hydrophobic biomaterial.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19142051

Source DB:  PubMed          Journal:  Medicina (Kaunas)        ISSN: 1010-660X            Impact factor:   2.430


  3 in total

1.  Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models.

Authors:  Ioannis T Tsinopoulos; Konstantinos T Tsaousis; George D Kymionis; Chrysanthos Symeonidis; Michael A Grentzelos; Vasilios F Diakonis; Maria Adaloglou; Stavros A Dimitrakos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-04-23       Impact factor: 3.117

2.  Effects of Residual Anterior Lens Epithelial Cell Removal on Axial Position of Intraocular Lens after Cataract Surgery.

Authors:  Seung Pil Bang; Young-Sik Yoo; Jong Hwa Jun; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2018-08-19       Impact factor: 1.909

3.  Posterior Capsule Opacification and Nd-YAG rates evaluation in a large series of pseudophakic cases.

Authors:  Ioana Madalina Iliescu; Maria Alexandra Constantin; Cristina Cozma; Ozana Manuela Moraru; Cristian Mircea Moraru
Journal:  Rom J Ophthalmol       Date:  2017 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.