Literature DB >> 29510870

A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction.

Jordan Stubleski1, Petr Kukucka2, Samira Salihovic3, P Monica Lind4, Lars Lind5, Anna Kärrman6.   

Abstract

The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 μL of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  APCI-MS/MS; GC-HRMS; High-throughput SPE; Persistent organic pollutants

Mesh:

Substances:

Year:  2018        PMID: 29510870     DOI: 10.1016/j.chroma.2018.02.057

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Targeted and Nontargeted Detection and Characterization of Trace Organic Chemicals in Human Serum and Plasma Using QuEChERS Extraction.

Authors:  Katherine E Manz; Kyle Yamada; Lukas Scheidl; Michele A La Merrill; Lars Lind; Kurt D Pennell
Journal:  Toxicol Sci       Date:  2021-12-28       Impact factor: 4.109

2.  The associations between p,p'-DDE levels and plasma levels of lipoproteins and their subclasses in an elderly population determined by analysis of lipoprotein content.

Authors:  Juliann Jugan; P Monica Lind; Samira Salihovic; Jordan Stubleski; Anna Kärrman; Lars Lind; Michele A La Merrill
Journal:  Lipids Health Dis       Date:  2020-12-07       Impact factor: 3.876

3.  [Simultaneous determination of 35 organochlorine pesticides and polychlorinated biphenyls in the serum of the general population in Wuhan by solid phase extraction-gas chromatography-tandem mass spectrometry].

Authors:  Xiang Li; Limei Wang; Lulu Song; Zhengce Wan; Jing Kou; Mingye Zhang; Yongman Lü; Youjie Wang; Surong Mei
Journal:  Se Pu       Date:  2022-05-08

4.  [Determination of polybrominated diphenyl ethers in serum using isotope internal standard-gas chromatography-high resolution dual-focus magnetic mass spectrometry].

Authors:  Mengmeng Wang; Linna Xie; Ying Zhu; Yifu Lu
Journal:  Se Pu       Date:  2022-04

5.  Evaluation of Solvents Used as Keepers in the Determination of Organic Pollutants by GC/MS.

Authors:  Łukasz Dąbrowski
Journal:  Molecules       Date:  2020-09-25       Impact factor: 4.411

6.  A two-step gas chromatography-tandem mass spectrometry method for measurement of multiple environmental pollutants in human plasma.

Authors:  Caitlin L Johnson; Elisa Jazan; Sek Won Kong; Kurt D Pennell
Journal:  Environ Sci Pollut Res Int       Date:  2020-09-10       Impact factor: 4.223

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.