Literature DB >> 29502964

Diagnosing Taper Corrosion: When Is It the Taper and When Is It Something Else?

Craig J Della Valle1, Tyler E Calkins1, Joshua J Jacobs1.   

Abstract

There has been an increasing use of modularity at the head-neck junction in total hip arthroplasty to more closely mimic the native anatomy, allowing for optimal leg length and stability. Corrosion at this junction in metal-on-polyethylene bearings can lead to an adverse local tissue reaction (ALTR). This increasingly prevalent condition should be considered in the differential diagnosis of hip pain and difficulty ambulating. A recent symposium by the American Academy of Hip and Knee Surgeons described the diagnosis, etiology, management, and prevention of taper corrosion. This article describes the history, physical, plain and advanced imaging findings, laboratory tests, and other diagnoses that should be taken into consideration when diagnosing taper corrosion. The presence of ALTR due to taper corrosion can mimic other diagnoses such as periprosthetic joint infection, instability, or aseptic loosening. Serum metal levels have been found to be the most effective screening tool for identifying corrosion, but other common causes of hip pain and difficulty ambulating should always be ruled out with the use of radiographs and common laboratory techniques before diagnosing ALTR due to corrosion.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  adverse local tissue reaction; chromium; cobalt; serum metal levels; taper corrosion; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29502964     DOI: 10.1016/j.arth.2018.01.054

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

Review 1.  What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2020-01-15       Impact factor: 4.757

2.  Additively Manufactured Ti6Al4V-Si-Hydroxyapatite composites for articulating surfaces of load-bearing implants.

Authors:  Jose D Avila; Zumurda Alrawahi; Susmita Bose; Amit Bandyopadhyay
Journal:  Addit Manuf       Date:  2020-04-23

3.  Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads?

Authors:  Stephanie M McCarthy; Deborah J Hall; Mathew T Mathew; Joshua J Jacobs; Hannah J Lundberg; Robin Pourzal
Journal:  Clin Orthop Relat Res       Date:  2021-09-01       Impact factor: 4.755

Review 4.  Metal ion levels with use of modular dual mobility constructs: Can the evidence guide us on clinical use?

Authors:  Atul F Kamath; P Maxwell Courtney; Gwo-Chin Lee
Journal:  J Orthop       Date:  2021-02-20
  4 in total