Literature DB >> 2949580

Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty.

J Tobis, O Nalcioglu, W D Johnston, L Qu, T Reese, D Sato, W Roeck, S Montelli, W L Henry.   

Abstract

Quantitative measurements of coronary stenoses were made from digital coronary angiograms in 19 patients before and after percutaneous transluminal coronary angioplasty (PTCA). Two methods of measurement were compared. Mean stenosis before PTCA was 67 +/- 10% by the edge detection method and 67 +/- 12% by videodensitometry (difference not significant). After PTCA, the mean stenosis was 32 +/- 14% by edge detection and 30 +/- 13% by videodensitometry (difference not significant). In addition, a new method was developed to rapidly calculate the absolute minimum luminal area and diameter by videodensitometry. The minimum luminal diameter before PTCA was 1.0 +/- 0.5 mm and after PTCA increased to 2.4 +/- 0.5 mm (p less than 0.001). The validity of the videodensitometric method was analyzed in a series of Lucite phantom studies, which suggested that when there is an irregular angiographic appearance, the densitometric method may be more accurate than standard edge detection methods. Digital acquisition of coronary angiograms provides a means for rapid application of quantitative analysis during coronary interventional procedures.

Entities:  

Mesh:

Year:  1987        PMID: 2949580     DOI: 10.1016/s0002-9149(87)80065-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  Features of the angiographic evaluation of the INTACT study. International Nifedipine Trial on Antiatherosclerotic Therapy.

Authors:  S Jost; J Deckers; W Rafflenbeul; H Hecker; U Nellessen; B Wiese; P G Hugenholtz; P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1990-08       Impact factor: 3.727

2.  Exercise in electrocardiography.

Authors:  M R O'grady; B Carley; D G Allen
Journal:  Can Vet J       Date:  1991-02       Impact factor: 1.008

3.  The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

Authors:  P A Doriot; P A Dorsaz; L Dorsaz; P Chatelain; W Rutishauser
Journal:  Int J Card Imaging       Date:  1996-12

4.  In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Authors:  S Molloi; A Ersahin; J Hicks; J Wallis
Journal:  Int J Card Imaging       Date:  1995-12

5.  Short-term and long-term treatment with propafenone: determinants of arrhythmia suppression, persistence of efficacy, arrhythmogenesis, and side effects in patients with symptoms.

Authors:  M Zehender; S Hohnloser; A Geibel; A Furtwängler; M Olschewski; T Meinertz; H Just
Journal:  Br Heart J       Date:  1992-06

6.  Limitation of detection and evaluation of coronary arterial stenosis by densitometry.

Authors:  T Sugahara; K Kimura; Y Yanagihara; N Sugimoto; T Azumi
Journal:  Int J Card Imaging       Date:  1994-03
  6 in total