Literature DB >> 29488886

Quality difference of neointima following the implantation of everolimus-eluting bioresorbable scaffolds and metallic stents in patients with ST-elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in the TROFI II trial.

Yohei Sotomi1, Yoshinobu Onuma, Shengnan Liu, Taku Asano, Jeroen Eggermont, Yuki Katagiri, Rafael Cavalcante, Robbert J de Winter, Joanna J Wykrzykowska, Salvatore Brugaletta, Lorenz Räber, Manel Sabaté, Stephan Windecker, Jouke Dijkstra, Patrick W Serruys.   

Abstract

AIMS: We aimed to assess possible differences in neointimal quality after everolimus-eluting bioresorbable scaffold (BVS) implantation in comparison with cobalt-chromium everolimus-eluting scaffold (CoCr-EES) implantation by optical frequency domain imaging (OFDI). METHODS AND
RESULTS: This study is a post hoc analysis of the TROFI II trial assessing neointimal quality six months after the implantation of BVS (N=82) and CoCr-EES (N=87) in STEMI patients. Neointimal light property analysis by OFDI fully automatically computed light attenuation, backscatter and light intensity for superficial and deep neointima. High light attenuation/backscatter and high light intensity are reportedly associated with lipidic change and tissue maturation, respectively. Superficial and deep neointima in BVS presented lower light attenuation than CoCr-EES (superficial: 0.77±0.15 vs. 1.27±0.55 mm-1, p<0.001; deep: 0.88±0.20 vs. 1.17±0.27 mm-1, p<0.001). Superficial neointima in BVS showed comparable backscatter to that of CoCr-EES (4.81±0.52 vs. 4.94±0.61, p=0.141), while deep neointima in BVS showed lower backscatter than that of CoCr-EES (4.60±0.62 vs. 4.97±0.62, p<0.001). Light intensity of superficial neointima was comparable between both arms (139±13 vs. 144±30, p=0.236), whereas light intensity of deep neointima in BVS was lower than CoCr-EES (129±14 vs. 138±21, p<0.001).
CONCLUSIONS: The present OFDI comparison suggested that tissue maturation was comparable but lipidic change of neointima was less prominent after BVS than after CoCr-EES implantation.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29488886     DOI: 10.4244/EIJ-D-17-00884

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  4 in total

1.  Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry.

Authors:  Tomoaki Kobayashi; Yohei Sotomi; Satoshi Suzuki; Yuma Hamanaka; Shimpei Nakatani; Jouke Dijkstra; Yoshinobu Onuma; Patrick W Serruys; Yasushi Sakata; Atsushi Hirayama; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2019-10-31       Impact factor: 2.357

2.  Comparable neointimal healing in patients with stable coronary lesions and acute coronary syndrome: 3-month optical coherence tomography analysis.

Authors:  Yuma Hamanaka; Yohei Sotomi; Tomoaki Kobayashi; Takashi Omatsu; Jouke Dijkstra; Yasushi Sakata; Atsushi Hirayama; Akio Hirata; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2021-02-16       Impact factor: 2.357

3.  Serial optical coherence tomography and angioscopic assessments of 10-year in-stent restenosis of Cypher sirolimus-eluting stent treated with drug-coated balloon angioplasty.

Authors:  Satoshi Suzuki; Shimpei Nakatani; Yohei Sotomi; Ichiro Shiojima; Yasushi Sakata; Yoshiharu Higuchi
Journal:  J Int Med Res       Date:  2019-04-02       Impact factor: 1.671

4.  Optical coherence tomography tissue coverage and characterization at six months after implantation of bioresorbable scaffolds versus conventional everolimus eluting stents in the ISAR-Absorb MI trial.

Authors:  Himanshu Rai; Fernando Alfonso; Michael Maeng; Christian Bradaric; Jens Wiebe; Javier Cuesta; Evald Høj Christiansen; Salvatore Cassese; Petra Hoppmann; Roisin Colleran; Fiona Harzer; Jola Bresha; Nejva Nano; Simon Schneider; Karl-Ludwig Laugwitz; Michael Joner; Adnan Kastrati; Robert A Byrne
Journal:  Int J Cardiovasc Imaging       Date:  2021-08-21       Impact factor: 2.357

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.