Literature DB >> 31673850

Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry.

Tomoaki Kobayashi1, Yohei Sotomi2, Satoshi Suzuki1, Yuma Hamanaka1, Shimpei Nakatani1, Jouke Dijkstra3, Yoshinobu Onuma4,5, Patrick W Serruys6, Yasushi Sakata7, Atsushi Hirayama1, Yoshiharu Higuchi1.   

Abstract

We aimed to quantitatively assess a possible difference of the neointimal quality between biodegradable polymer- (BP-) and durable polymer drug-eluting stents (DP-DESs). We conducted a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful OCT examination at planned 3-month follow-up after DES implantation were analyzed. Study population was divided into 2 groups, BP-DES versus DP-DES groups. We evaluated standard OCT variables, coverage percent, and the quantitative light property values including light intensity, attenuation, and backscatter. We performed OCT analyses of 121 lesions in 98 patients (BP-DES 55 lesions in 51 patients vs. DP-DES 66 lesions in DP-DES 53 patients). Lesion and procedural characteristics were overall well-balanced between both groups. At 3-month follow-up, neointimal thickness (BP-DES 49.3 [38.2, 57.7] µm versus DP-DES 54.7 [45.1, 70.7] µm, p = 0.059) and coverage percent (BP-DES 94.5 [89.8, 97.0]% vs. DP-DES 95.8 [91.1, 98.1]%, p = 0.083) did not significantly differ. Light intensity of superficial neointima in the BP-DES was lower than that in the DP-DES, whereas that of deep neointima did not differ between both groups. Both superficial and deep neointima of the BP-DES presented significantly lower light attenuation and backscatter than those of the DP-DES did. Almost complete coverage at 3 months in both contemporary BP- and DP-DES would support the ultra-short DAPT strategy in the upcoming decade. Nevertheless, there was a significant difference in the neointimal characteristics on OCT light property 3 months after BP- versus DP-DES implantation.Trial Registration UMIN000033009.

Entities:  

Keywords:  Biodegradable polymer; Drug-eluting stent; Durable polymer; Light property analysis; Optical coherence tomography

Mesh:

Substances:

Year:  2019        PMID: 31673850     DOI: 10.1007/s10554-019-01718-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study.

Authors:  Srihari S Naidu; Mitchell W Krucoff; David R Rutledge; Vivian W Mao; Weiying Zhao; Qing Zheng; Olivia Wilburn; Krishnankutty Sudhir; Charles Simonton; James B Hermiller
Journal:  JACC Cardiovasc Interv       Date:  2012-06       Impact factor: 11.195

2.  Correlation between degree of neointimal hyperplasia and incidence and characteristics of neoatherosclerosis as assessed by optical coherence tomography.

Authors:  Rocco Vergallo; Taishi Yonetsu; Shiro Uemura; Seung-Jung Park; Stephen Lee; Koji Kato; Haibo Jia; Farhad Abtahian; Jinwei Tian; Sining Hu; Hang Lee; Iris McNulty; Abhiram Prasad; Bo Yu; Shaosong Zhang; Italo Porto; Luigi M Biasucci; Filippo Crea; Ik-Kyung Jang
Journal:  Am J Cardiol       Date:  2013-07-26       Impact factor: 2.778

Review 3.  Biological responses in stented arteries.

Authors:  Chiraz Chaabane; Fumiyuki Otsuka; Renu Virmani; Marie-Luce Bochaton-Piallat
Journal:  Cardiovasc Res       Date:  2013-05-10       Impact factor: 10.787

4.  Tissue characterization with depth-resolved attenuation coefficient and backscatter term in intravascular optical coherence tomography images.

Authors:  Shengnan Liu; Yohei Sotomi; Jeroen Eggermont; Gaku Nakazawa; Sho Torii; Takeshi Ijichi; Yoshinobu Onuma; Patrick W Serruys; Boudewijn P F Lelieveldt; Jouke Dijkstra
Journal:  J Biomed Opt       Date:  2017-09       Impact factor: 3.170

5.  A first-in-man clinical evaluation of Ultimaster, a new drug-eluting coronary stent system: CENTURY study.

Authors:  Emanuele Barbato; Sonja Salinger-Martinovic; Dragan Sagic; Branko Beleslin; Mathias Vrolix; Aleksandar N Neskovic; Nikola Jagic; Stefan Verheye; Zlatko Mehmedbegovic; William Wijns
Journal:  EuroIntervention       Date:  2015-09       Impact factor: 6.534

6.  Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry.

Authors:  Satoshi Suzuki; Yohei Sotomi; Tomoaki Kobayashi; Yuma Hamanaka; Shimpei Nakatani; Ichiro Shiojima; Yasushi Sakata; Atsushi Hirayama; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2019-03-14       Impact factor: 2.357

7.  Tissue characterization after drug-eluting stent implantation using optical coherence tomography.

Authors:  Caroline Malle; Tomohisa Tada; Kristin Steigerwald; Giovanni J Ughi; Tibor Schuster; Masataka Nakano; Steffen Massberg; Johannes Jehle; Giulio Guagliumi; Adnan Kastrati; Renu Virmani; Robert A Byrne; Michael Joner
Journal:  Arterioscler Thromb Vasc Biol       Date:  2013-03-28       Impact factor: 8.311

8.  Intraplaque hemorrhage and progression of coronary atheroma.

Authors:  Frank D Kolodgie; Herman K Gold; Allen P Burke; David R Fowler; Howard S Kruth; Deena K Weber; Andrew Farb; L J Guerrero; Motoya Hayase; Robert Kutys; Jagat Narula; Aloke V Finn; Renu Virmani
Journal:  N Engl J Med       Date:  2003-12-11       Impact factor: 91.245

9.  Drug-eluting stents in elderly patients with coronary artery disease (SENIOR): a randomised single-blind trial.

Authors:  Olivier Varenne; Stéphane Cook; Georgios Sideris; Sasko Kedev; Thomas Cuisset; Didier Carrié; Thomas Hovasse; Philippe Garot; Rami El Mahmoud; Christian Spaulding; Gérard Helft; José F Diaz Fernandez; Salvatore Brugaletta; Eduardo Pinar-Bermudez; Josepa Mauri Ferre; Philippe Commeau; Emmanuel Teiger; Kris Bogaerts; Manel Sabate; Marie-Claude Morice; Peter R Sinnaeve
Journal:  Lancet       Date:  2017-11-01       Impact factor: 79.321

10.  Experimental evaluation of efficacy and healing response of everolimus-eluting stents in the familial hypercholesterolemic swine model: a comparative study of bioabsorbable versus durable polymer stent platforms.

Authors:  Armando Tellez; Paul S Seifert; Elina Donskoy; Natalia Sushkova; Douglas E Pennington; Krzysztof Milewski; Christian G Krueger; Greg L Kaluza; Michael J Eppihimer; Barbara A Huibregtse; Keith D Dawkins; Juan F Granada
Journal:  Coron Artery Dis       Date:  2014-05       Impact factor: 1.439

View more
  3 in total

1.  Comparable neointimal healing in patients with stable coronary lesions and acute coronary syndrome: 3-month optical coherence tomography analysis.

Authors:  Yuma Hamanaka; Yohei Sotomi; Tomoaki Kobayashi; Takashi Omatsu; Jouke Dijkstra; Yasushi Sakata; Atsushi Hirayama; Akio Hirata; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2021-02-16       Impact factor: 2.357

2.  Quantitative Validation of the Coronary Angioscopic Yellow Plaque with Lipid Core Burden Index Assessed by Intracoronary Near-Infrared Spectroscopy.

Authors:  Takashi Omatsu; Yohei Sotomi; Tomoaki Kobayashi; Yuma Hamanaka; Akio Hirata; Atsushi Hirayama; Yasunori Ueda; Yasushi Sakata; Yoshiharu Higuchi
Journal:  J Atheroscler Thromb       Date:  2021-01-22       Impact factor: 4.928

3.  Comparison of 6-month vascular healing response after bioresorbable polymer versus durable polymer drug-eluting stent implantation in patients with acute coronary syndromes: A randomized serial optical coherence tomography study.

Authors:  Masahiko Noguchi; Tomotaka Dohi; Shinya Okazaki; Mitsuaki Matsumura; Mitsuhiro Takeuchi; Hirohisa Endo; Yoshiteru Kato; Iwao Okai; Hiroki Nishiyama; Shinichiro Doi; Hiroshi Iwata; Kikuo Isoda; Eisuke Usui; Tatsuhiro Fujimura; Fumiyasu Seike; Gary S Mintz; Katsumi Miyauchi; Hiroyuki Daida; Tohru Minamino; Akiko Maehara
Journal:  Catheter Cardiovasc Interv       Date:  2021-08-06       Impact factor: 2.585

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.