Literature DB >> 2948376

Quantitative phase-flow MR imaging in dogs by using standard sequences: comparison with in vivo flow-meter measurements.

R I Pettigrew, W Dannels, J R Galloway, T Pearson, W Millikan, J M Henderson, J Peterson, M E Bernardino.   

Abstract

For evaluation of the feasibility and clinical potential of using the phase data from standard MR imaging sequences to measure blood flow, 11 vessels with diameters of 4 to 7 mm were imaged in seven dogs. The flow in either the superior mesenteric vein or the inferior vena cava was measured first at laparotomy (in ml/min) with electromagnetic flow meters. Immediately thereafter, these vessels were imaged by MR in 25-mm thick sections by using a standard spin echo (SE) 750/30 sequence with a Philips 0.5-T imager. Previous phase-flow calibration of the imager and sequence allowed calculation of the blood flow rates from the phase images that were used to measure the vessels' cross-sectional areas and blood phase values. Comparison of the measurements obtained with each technique showed a significant correlation (r = .977, p less than .05) between MR-imaging values and flow-meter measurements when the blood velocity was less than approximately 40 cm/sec, the known upper limit of the flow dynamic range for the MR hardware and sequence used. There was no correlation for blood velocities greater than 40 cm/sec. However, the range of blood flow velocities in dogs and man extends to more than 100 cm/sec. Thus, these results suggest that this technique might yield valuable adjunctive flow data in routine clinical imaging provided that improvements in hardware and software permit a larger dynamic range.

Entities:  

Mesh:

Year:  1987        PMID: 2948376     DOI: 10.2214/ajr.148.2.411

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Complex flow patterns in the great vessels: a review.

Authors:  H G Bogren; M H Buonocore
Journal:  Int J Card Imaging       Date:  1999-04

2.  MR phase imaging and cerebrospinal fluid flow in the head and spine.

Authors:  L M Levy; G Di Chiro
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

3.  In vivo evaluation of quantitative MR angiography in a canine carotid artery stenosis model.

Authors:  M Calderon-Arnulphi; S Amin-Hanjani; A Alaraj; M Zhao; X Du; S Ruland; X J Zhou; K R Thulborn; F T Charbel
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

4.  Stroboscopic nuclear magnetic resonance microscopy of arterial blood flow.

Authors:  R W Behling; H K Tubbs; M D Cockman; L W Jelinski
Journal:  Biophys J       Date:  1990-07       Impact factor: 4.033

5.  Respiratory self-gating for free-breathing abdominal phase-contrast blood flow measurements.

Authors:  Ning Jin; Robert J Lewandowski; Reed A Omary; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813