Literature DB >> 29473178

PAS-C platelets contain less plasma protein, lower anti-A and anti-B titers, and decreased HLA antibody specificities compared to plasma platelets.

Stuart P Weisberg1, Beth H Shaz1, Gizem Tumer2, Chris C Silliman3, Marguerite R Kelher3, Claudia S Cohn2.   

Abstract

BACKGROUND: Platelets (PLTs) collected and stored in PLT additive solution Intersol (PAS-C) are presumed to reduce recipient exposure to donor plasma components; however, the effects of PAS-C on PLT supernatant composition are poorly defined. Therefore, we compared the total protein concentration, isohemagglutinin titers, and HLA antibodies in supernatants of PAS-C PLTs to plasma PLTs. STUDY DESIGN AND METHODS: Apheresis PLTs from group O blood donors were collected into either 100% donor plasma (n = 50) or a mixture of 65% PAS-C/35% donor plasma (n = 50). Within 12 hours of collection, samples of the PLT supernatant were frozen and stored. PLT supernatants were assayed for total protein concentration and anti-A and anti-B titers and screened for HLA antibodies. Samples positive for HLA antibodies were further tested using single-antigen bead assays to determine antibody strength and specificity.
RESULTS: Supernatants of PAS-C PLTs had significantly lower total protein concentration and anti-A and anti-B titers compared to plasma PLTs. There was no significant difference in the number of HLA antibody screen-positive PAS-C (3/50) compared to plasma PLT supernatants (2/50); however, the HLA antibody screen-positive supernatants of PAS-C PLTs had fewer HLA specificities (2) compared to those of the plasma PLTs (18).
CONCLUSION: Decreased plasma proteins likely underlie lower rates of allergic and febrile, nonhemolytic transfusion reactions from the infusion of PAS-C PLTs. Decreased anti-A and anti-B titers may prevent hemolysis from minor ABO mismatch. Lower HLA antibody specificities may mitigate transfusion-related acute lung injury.
© 2018 AABB.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29473178     DOI: 10.1111/trf.14523

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  5 in total

1.  Comparison of Quality and Efficacy of Apheresis Platelets Stored in Platelet Additive Solution Vis a Vis Plasma.

Authors:  Debapriya Basu; Sabita Basu; Vivek S Radhakrishnan; Sanjay Bhattacharya; Subhosmito Chakraborty; Subir Sinha; Mammen Chandy
Journal:  Indian J Hematol Blood Transfus       Date:  2021-03-12       Impact factor: 0.915

2.  A Study on Influence of Donor Hematocrit on the Procedural Parameters of Concentrated Single Donor Platelets Collected by Two Apheresis Devices.

Authors:  Gayathiri K Chellaiya; M Murugesan; Sangeetha K Nayanar
Journal:  Indian J Hematol Blood Transfus       Date:  2019-07-27       Impact factor: 0.900

3.  Influence of apheresis collection device and container on the storage properties of platelets in 90% PAS-5/10% plasma.

Authors:  Stephen J Wagner; Cheryl A Hapip; Annette Turgeon; Lenora Abel; Nadine Kaelber
Journal:  Blood Transfus       Date:  2018-09-05       Impact factor: 3.443

4.  Quality improvement with platelet additive solution for safer out-of-group platelet transfusions.

Authors:  Maxim Tynuv; Willy A Flegel
Journal:  Immunohematology       Date:  2019-09

5.  Comparison of abo antibody levels in apheresis platelets suspended in platelet additive solution and plasma.

Authors:  Gayathiri Kc; Mohandoss Murugesan; Sangeetha K Nayanar; Riyas Malodan; Maya Padmanaban
Journal:  Hematol Transfus Cell Ther       Date:  2020-06-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.