Abstract
PAS, by replacing part of the plasma in the platelet storage bag, reduces post transfusion allergic reactions and DHTR in the recipient. In this study we compared quality and efficacy of PAS and usual plasma stored platelets. Platelet concentration, content, MPV, pH, swirling, LDH and glucose concentration were tested in SDPs after preparation and on the day of transfusion; and compared between control (plasma-stored SDP) and study (PAS-stored SDP) groups. CCI was compared between the two groups. Transfusion reactions were also noted. In both groups quality parameters were similar except glucose [significantly decreased (p < 0.001) in plasma] and LDH [increased significantly (p: -0.005) in PAS]. CCI was similar in both groups. Transfusion reaction rate were 0.012% and 0.049% in both groups respectively. Quality and post-transfusion efficacy in both groups were similar. PAS stored platelets may be transfused in multi-transfused patients with allergic manifestations and in minor ABO incompatible transfusions. © Indian Society of Hematology and Blood Transfusion 2021.Entities:
Keywords: DHTR; Platelet additive solution; Transfusion reaction