Comparison of Quality and Efficacy of Apheresis Platelets Stored in Platelet Additive Solution Vis a Vis Plasma.

Debapriya Basu1, Sabita Basu1, Vivek S Radhakrishnan2, Sanjay Bhattacharya3, Subhosmito Chakraborty4, Subir Sinha5, Mammen Chandy2.   

Abstract

PAS, by replacing part of the plasma in the platelet storage bag, reduces post transfusion allergic reactions and DHTR in the recipient. In this study we compared quality and efficacy of PAS and usual plasma stored platelets. Platelet concentration, content, MPV, pH, swirling, LDH and glucose concentration were tested in SDPs after preparation and on the day of transfusion; and compared between control (plasma-stored SDP) and study (PAS-stored SDP) groups. CCI was compared between the two groups. Transfusion reactions were also noted. In both groups quality parameters were similar except glucose [significantly decreased (p < 0.001) in plasma] and LDH [increased significantly (p: -0.005) in PAS]. CCI was similar in both groups. Transfusion reaction rate were 0.012% and 0.049% in both groups respectively. Quality and post-transfusion efficacy in both groups were similar. PAS stored platelets may be transfused in multi-transfused patients with allergic manifestations and in minor ABO incompatible transfusions. © Indian Society of Hematology and Blood Transfusion 2021.

Entities:  

Keywords:  DHTR; Platelet additive solution; Transfusion reaction

Year:  2021        PMID: 34744347      PMCID: PMC8523622          DOI: 10.1007/s12288-021-01408-x

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.915


  42 in total

1.  The absence of swirling in platelet concentrates is highly predictive of poor posttransfusion platelet count increments and increased risk of a transfusion reaction.

Authors:  F Bertolini; A Agazzi; F Peccatori; G Martinelli; M T Sandri
Journal:  Transfusion       Date:  2000-01       Impact factor: 3.157

2.  Current status of additive solutions for platelets.

Authors:  Hiba Alhumaidan; Joseph Sweeney
Journal:  J Clin Apher       Date:  2012-02-02       Impact factor: 2.821

3.  Storage of buffy-coat-derived platelets in additive solutions: in vitro effects on platelets stored in reformulated PAS supplied by a 20% plasma carry-over.

Authors:  P Sandgren; V Mayaudon; J-M Payrat; A Sjödin; H Gulliksson
Journal:  Vox Sang       Date:  2009-09-24       Impact factor: 2.144

Review 4.  PAS or plasma for storage of platelets? A concise review.

Authors:  P F van der Meer
Journal:  Transfus Med       Date:  2016-06-07       Impact factor: 2.019

5.  Acute intravascular hemolysis secondaryto out-of-group platelet transfusion.

Authors:  L G Larsson; V J Welsh; D J Ladd
Journal:  Transfusion       Date:  2000-08       Impact factor: 3.157

Review 6.  Platelet Additive Solutions: A Review of the Latest Developments and Their Clinical Implications.

Authors:  Pieter F van der Meer; Dirk de Korte
Journal:  Transfus Med Hemother       Date:  2018-03-09       Impact factor: 3.747

7.  Evaluation of platelet storage lesions in platelet concentrates stored for seven days.

Authors:  Harprit Singh; Rajendra Chaudhary; Vijayalaxmi Ray
Journal:  Indian J Med Res       Date:  2003-12       Impact factor: 2.375

8.  Platelet storage lesion: An update.

Authors:  Kshitija Mittal; Ravneet Kaur
Journal:  Asian J Transfus Sci       Date:  2015 Jan-Jun

9.  Acute Intravascular Hemolysis Following an ABO Non-Identical Platelet Transfusion: A Case Report and Literature Review.

Authors:  Imran A Moinuddin; Peter Millward; Craig H Fletcher
Journal:  Am J Case Rep       Date:  2019-07-23

10.  Acute Hemolytic Transfusion Reaction in Group B Recipient Associated with Group A Apheresis Platelet Donor: Case Report and Literature Review.

Authors:  Tracy R Shachner; Christopher T Clark
Journal:  Case Rep Med       Date:  2018-06-24
View more