Literature DB >> 29471995

Should We Keep the Lead in the Aprons?

Gabriel Bartal1, Anna M Sailer2, Eliseo Vano3.   

Abstract

Medical staff should not be exposed to the primary X-ray beam during fluoroscopy-guided interventional procedures (FGIP). The main source of staff exposure is scatter radiation from the patient, which can be significant. Although many aspects of X-ray exposure to the patient as well as occupational exposure to interventional radiologists and other staff are strongly regulated and monitored in most countries, it is surprising how loosely the labeling and testing of the protective aprons is regulated. Interventional radiologists (IRs) have to be experts in interventional radiology as well as in basic facts regarding ways to provide a satisfactory level of protection from occupational exposure. IRs, however, are not familiar with the apron testing methods. The accompanying documents provided with aprons by manufacturers may not be informative enough. Vendors often report apron effectiveness at a single beam quality and attenuation. The vendor reports repeatedly disagree with independent reports, which clearly show that the attenuation of these garments at other important unreported energies may be lower than expected. Better trust no one and check your protective garment yourself, or, better yet, consult a medical physicist when making purchasing decisions related to protective garments. Each interventionist should choose garments that are appropriately protective for that individual's practice. Review of past personal dosimetry results and consultation with a medical physicist can help the IR make the best decision. This article will help the reader to understand why all protective garments are not created equally, and provides some practical tools that will allow safe and healthy practice in FGIP.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  occupational exposure; personnel radiation safety; protective aprons

Mesh:

Substances:

Year:  2017        PMID: 29471995     DOI: 10.1053/j.tvir.2017.12.002

Source DB:  PubMed          Journal:  Tech Vasc Interv Radiol        ISSN: 1557-9808


  5 in total

Review 1.  Strategies for Minimizing Occupational Radiation Exposure in Cardiac Imaging.

Authors:  Samia Massalha; Aws Almufleh; Garry Small; Brian Marvin; Zohar Keidar; Ora Israel; John A Kennedy
Journal:  Curr Cardiol Rep       Date:  2019-06-21       Impact factor: 2.931

2.  Evaluation and verification of a simplified lead equivalency measurement method.

Authors:  Richard Ryan Wargo; Areej Fawzi Aljabal; Pei-Jan Paul Lin
Journal:  J Appl Clin Med Phys       Date:  2020-01-08       Impact factor: 2.102

3.  Anti-X Apron Wearing and Musculoskeletal Problems Among Healthcare Workers: A Systematic Scoping Review.

Authors:  Maria Grazia Lourdes Monaco; Angela Carta; Tishad Tamhid; Stefano Porru
Journal:  Int J Environ Res Public Health       Date:  2020-08-13       Impact factor: 3.390

Review 4.  Get Protected! Recommendations for Staff in IR.

Authors:  Gabriel Bartal; Eliseo Vano; Graciano Paulo
Journal:  Cardiovasc Intervent Radiol       Date:  2021-04-09       Impact factor: 2.740

5.  Impact of radiotherapy and shielding on the efficacy of the self-etch adhesive technique.

Authors:  Saurabh Gupta; Poonam Bogra; Deepak Sharma; Radhika Goyal; Saru Dhir; Bharat Gupta
Journal:  J Conserv Dent       Date:  2022-08-02