Literature DB >> 29469203

Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve.

Cristina Montealegre1, Christian Neusüß1.   

Abstract

Imaged capillary isoelectric focusing (iCIEF) is a powerful separation technique applied frequently for the analysis of biotherapeutics. However, direct mass spectrometric characterization is usually not possible. Here, focused peaks from an iCIEF system are transferred to a four-port nanoliter valve where peaks of interest are cut and transferred directly (flow injection) or via capillary zone electrophoresis to electrospray mass spectrometry. At first, flow injection coupling was tested with a mixture of peptides showing intraday precision (RSD) of 20.0 and 3.4% in area and 15.2 and 6.3% in intensity for angiotensin I and leucine-enkephalin, respectively. For the analysis of charge variants in an intact mAb, flow injection and CZE as second dimension were compared, demonstrating the usability of flow injection even for large proteins. However, improved spectra quality was achieved when CZE-MS was applied. In this way, accurate masses were obtained not only for the main isoform, but also for the main acidic and basic variants. These results demonstrate the power of iCIEF-CZE-MS for the analysis of biotherapeutics.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Antibody analysis; Capillary zone electrophoresis-mass spectrometry; Charge variants; Imaged capillary isoelectric focusing; Two-dimensional

Mesh:

Substances:

Year:  2018        PMID: 29469203     DOI: 10.1002/elps.201800013

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

Review 1.  Challenging Bioanalyses with Capillary Electrophoresis.

Authors:  Courtney J Kristoff; Lloyd Bwanali; Lindsay M Veltri; Gayatri P Gautam; Patrick K Rutto; Ebenezer O Newton; Lisa A Holland
Journal:  Anal Chem       Date:  2019-12-02       Impact factor: 6.986

2.  Low Flow Voltage Free Interface for Capillary Electrophoresis and Mass Spectrometry Driven by Vibrating Sharp-Edge Spray Ionization.

Authors:  Courtney J Kristoff; Chong Li; Peng Li; Lisa A Holland
Journal:  Anal Chem       Date:  2020-02-07       Impact factor: 6.986

Review 3.  Recent advances (2019-2021) of capillary electrophoresis-mass spectrometry for multilevel proteomics.

Authors:  Daoyang Chen; Elijah N McCool; Zhichang Yang; Xiaojing Shen; Rachele A Lubeckyj; Tian Xu; Qianjie Wang; Liangliang Sun
Journal:  Mass Spectrom Rev       Date:  2021-06-15       Impact factor: 10.946

4.  Evaluation of an icIEF-MS system for comparable charge variant analysis of biotherapeutics with rapid peak identification by mass spectrometry.

Authors:  Xiaoping He; Mariam ElNaggar; Maggie A Ostrowski; Andras Guttman; Erik Gentalen; Justin Sperry
Journal:  Electrophoresis       Date:  2022-04-26       Impact factor: 3.595

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.