Literature DB >> 29466273

Heart Rate Variability During Exercise: A Comparison of Artefact Correction Methods.

David A Giles1, Nick Draper2.   

Abstract

Giles, DA and Draper, N. Heart rate variability during exercise: a comparison of artefact correction methods. J Strength Cond Res 32(3): 726-735, 2018-There is a need for standard practice in the collection and processing of RR interval data recorded using heart rate monitors (HRMs) in research. This article assessed the validity of RR intervals and heart rate variability (HRV) data obtained using an HRM during incremental exercise and artefact correction methods. Eighteen participants completed an active orthostatic test and incremental running V[Combining Dot Above]O2max test, while simultaneous recordings using a Polar V800 HRM and an electrocardiogram were made. Artefacts were corrected by deletion; degree zero, linear, cubic, and spline interpolation; and Kubios HRV software. Agreement was assessed using percentage bias, effect size (ES), intraclass correlation coefficients (ICC), and Bland-Altman limits of agreement (LoA). Artefacts increased relative to exercise intensity, to a peak of 4.46% during 80-100% V[Combining Dot Above]O2max. Correction of RR intervals was necessary with unacceptably increased bias, LoA, and ES and reduced ICC in all but resting recordings. All correction methods resulted in data with reduced percentage bias and ES for resting and <60% V[Combining Dot Above]O2max recordings. However, at >60% V[Combining Dot Above]O2max, even with correction, large amounts of variation were present in HRV measures of root mean square of the successive difference of intervals, low-to-high frequency ratio, Poincaré dispersion perpendicular to the axis (SD1), and sample entropy. Linear interpolation produced RR intervals with the lowest bias and ES. However, caution should be given to HRV parameters at high exercise intensities, as large amounts of variation were still present. Recommendations for minimizing artefacts are discussed, along with guidelines for their identification, correction, and reporting.

Entities:  

Mesh:

Year:  2018        PMID: 29466273     DOI: 10.1519/JSC.0000000000001800

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  9 in total

1.  The acute, systemic effects of aerobic exercise in recently concussed adolescent student-athletes: preliminary findings.

Authors:  P R Worts; J R Mason; S O Burkhart; M A Sanchez-Gonzalez; J-S Kim
Journal:  Eur J Appl Physiol       Date:  2022-03-18       Impact factor: 3.078

2.  Validation of the Polar V800 heart rate monitor and comparison of artifact correction methods among adults with hypertension.

Authors:  Burak Cilhoroz; David Giles; Amanda Zaleski; Beth Taylor; Bo Fernhall; Linda Pescatello
Journal:  PLoS One       Date:  2020-10-08       Impact factor: 3.240

3.  Influence of Artefact Correction and Recording Device Type on the Practical Application of a Non-Linear Heart Rate Variability Biomarker for Aerobic Threshold Determination.

Authors:  Bruce Rogers; David Giles; Nick Draper; Laurent Mourot; Thomas Gronwald
Journal:  Sensors (Basel)       Date:  2021-01-26       Impact factor: 3.576

4.  Concurrent Evolution of Biomechanical and Physiological Parameters With Running-Induced Acute Fatigue.

Authors:  Gäelle Prigent; Salil Apte; Anisoara Paraschiv-Ionescu; Cyril Besson; Vincent Gremeaux; Kamiar Aminian
Journal:  Front Physiol       Date:  2022-02-11       Impact factor: 4.566

5.  Heart rate variability in children: methodological issues and clinical applications.

Authors:  Iván Rodríguez-Núñez; Natalia Rodríguez-Romero; Alejandro Álvarez; Lysien Zambrano; Glaucia Luciano da Veiga; Fernando Romero
Journal:  Arch Cardiol Mex       Date:  2022-04-04

6.  Effects of Missing Data on Heart Rate Variability Metrics.

Authors:  Diego Cajal; David Hernando; Jesús Lázaro; Pablo Laguna; Eduardo Gil; Raquel Bailón
Journal:  Sensors (Basel)       Date:  2022-08-02       Impact factor: 3.847

7.  Heart Rate Behavior in Speed Climbing.

Authors:  Franz Konstantin Fuss; Adin Ming Tan; Stefanie Pichler; Günther Niegl; Yehuda Weizman
Journal:  Front Psychol       Date:  2020-07-07

8.  Daily Heart Rate Variability Indices in Subjects with and Without Metabolic Syndrome Before and After the Elimination of the Influence of Day-Time Physical Activity.

Authors:  Anžela Slušnienė; Aleksandras Laucevičius; Petras Navickas; Ligita Ryliškytė; Vytautas Stankus; Albinas Stankus; Rokas Navickas; Ieva Laucevičienė; Vytautas Kasiulevičius
Journal:  Medicina (Kaunas)       Date:  2019-10-17       Impact factor: 2.430

9.  Artifact Correction in Short-Term HRV during Strenuous Physical Exercise.

Authors:  Aleksandra Królak; Tomasz Wiktorski; Magnus Friestad Bjørkavoll-Bergseth; Stein Ørn
Journal:  Sensors (Basel)       Date:  2020-11-08       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.