Literature DB >> 29461807

Soft Argon-Propane Dielectric Barrier Discharge Ionization.

Alexander Schütz1, Felipe J Lara-Ortega2, Felix David Klute1, Sebastian Brandt1, Michael Schilling1, Antje Michels1, Damir Veza3, Vlasta Horvatic4, Juan F García-Reyes2, Joachim Franzke1.   

Abstract

Dielectric barrier discharges (DBDs) have been used as soft ionization sources (DBDI) for organic mass spectrometry (DBDI-MS) for approximately ten years. Helium-based DBDI is often used because of its good ionization efficiency, low ignition voltage, and homogeneous plasma conditions. Argon needs much higher ignition voltages than helium when the same discharge geometry is used. A filamentary plasma, which is not suitable for soft ionization, may be produced instead of a homogeneous plasma. This difference results in N2, present in helium and argon as an impurity, being Penning-ionized by helium but not by metastable argon atoms. In this study, a mixture of argon and propane (C3H8) was used as an ignition aid to decrease the ignition and working voltages, because propane can be Penning-ionized by argon metastables. This approach leads to homogeneous argon-based DBDI. Furthermore, operating DBDI in an open environment assumes that many uncharged analyte molecules do not interact with the reactant ions. To overcome this disadvantage, we present a novel approach, where the analyte is introduced in an enclosed system through the discharge capillary itself. This nonambient DBDI-MS arrangement is presented and characterized and could advance the novel connection of DBDI with analytical separation techniques such as gas chromatography (GC) and high-pressure liquid chromatography (HPLC) in the near future.

Entities:  

Year:  2018        PMID: 29461807     DOI: 10.1021/acs.analchem.7b05390

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  1,4-Benzoquinone as a Highly Efficient Dopant for Enhanced Ionization and Detection of Nitramine Explosives on a Single-Quadrupole Mass Spectrometer Fitted with a Helium-Plasma Ionization (HePI) Source.

Authors:  Julius Pavlov; David Douce; Steve Bajic; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2019-10-31       Impact factor: 3.109

2.  Liquid chromatography-dielectric barrier discharge ionization mass spectrometry for the analysis of neutral lipids of archaeological interest.

Authors:  Marcos Bouza; Julio García-Martínez; Bienvenida Gilbert-López; David Moreno-González; Priscilla Rocío-Bautista; David Parras-Guijarro; Alberto Sánchez-Vizcaino; Sebastian Brandt; Juan F García-Reyes; Antonio Molina-Díaz; Joachim Franzke
Journal:  J Sep Sci       Date:  2022-07-14       Impact factor: 3.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.