Carla Serra 1 , Valentina Grasso 1 , Fabio Conti 2 , Cristina Felicani 1 , Elena Mazzotta 1 , Marco Lenzi 2 , Gabriella Verucchi 2 , Antonietta D'errico 3 , Pietro Andreone 2 . Show Affiliations »
Abstract
PURPOSE: To assess the performance of two-dimensional shear wave elastography (2D-SWE) on the GE LOGIQ E9 ultrasound system in a cohort of healthy subjects and to investigate its accuracy in the staging of liver fibrosis in patients with chronic liver disease (CLD) using liver biopsy as a reference standard. MATERIALS AND METHODS: From October 2014 to June 2016, 54 healthy subjects and 174 patients with CLD were consecutively enrolled. Liver fibrosis stage was assessed by the METAVIR scoring system. 18 (10.3 %) and 17 (9.8 %) patients had advanced fibrosis and cirrhosis, respectively. The correlation of liver stiffness measurement (LSM) and continuous variable was assessed using the Spearman rank correlation. The accuracy of 2D-SWE was evaluated with areas under the receiver operating characteristics curves (AUROC). RESULTS: Reliable LSMs were obtained in all subjects. The interobserver agreement ICC was excellent: 0.847. In healthy subjects, gender, but not anthropometric and biochemical data, were correlated with LSM. In patients with CLD, LSM had a strong positive correlation with fibrosis stage (rho = 0.628; p > 0.001). The AUROC was 0.724 for mild fibrosis (F≥ 1), 0.857 for moderate fibrosis (F≥ 2), 0.946 for severe fibrosis (F≥ 3), and 0.935 for cirrhosis (F4). Likewise, good accuracy was observed in the HCV subgroup. The optimal cut-off value in differentiating healthy subjects from CLD patients with any fibrosis was 5.47 kPa with an AUROC of 0.875. CONCLUSION: 2D-SWE is a reliable and reproducible method to assess LSM with good diagnostic accuracy to assess liver fibrosis in patients with CLD. © Georg Thieme Verlag KG Stuttgart · New York.
PURPOSE: To assess the performance of two-dimensional shear wave elastography (2D-SWE) on the GE LOGIQ E9 ultrasound system in a cohort of healthy subjects and to investigate its accuracy in the staging of liver fibrosis in patients with chronic liver disease (CLD) using liver biopsy as a reference standard. MATERIALS AND METHODS: From October 2014 to June 2016, 54 healthy subjects and 174 patients with CLD were consecutively enrolled. Liver fibrosis stage was assessed by the METAVIR scoring system. 18 (10.3 %) and 17 (9.8 %) patients had advanced fibrosis and cirrhosis, respectively. The correlation of liver stiffness measurement (LSM) and continuous variable was assessed using the Spearman rank correlation. The accuracy of 2D-SWE was evaluated with areas under the receiver operating characteristics curves (AUROC). RESULTS: Reliable LSMs were obtained in all subjects. The interobserver agreement ICC was excellent: 0.847. In healthy subjects, gender, but not anthropometric and biochemical data, were correlated with LSM. In patients with CLD, LSM had a strong positive correlation with fibrosis stage (rho = 0.628; p > 0.001). The AUROC was 0.724 for mild fibrosis (F≥ 1), 0.857 for moderate fibrosis (F≥ 2), 0.946 for severe fibrosis (F≥ 3), and 0.935 for cirrhosis (F4). Likewise, good accuracy was observed in the HCV subgroup. The optimal cut-off value in differentiating healthy subjects from CLD patients with any fibrosis was 5.47 kPa with an AUROC of 0.875. CONCLUSION: 2D-SWE is a reliable and reproducible method to assess LSM with good diagnostic accuracy to assess liver fibrosis in patients with CLD. © Georg Thieme Verlag KG Stuttgart · New York.
Entities: Chemical
Mesh: See more »
Year: 2018
PMID: 29458217 DOI: 10.1055/s-0043-119356
Source DB: PubMed Journal: Ultraschall Med ISSN: 0172-4614 Impact factor: 6.548