Literature DB >> 2945500

A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

K Poots, R S Cobbold, K W Johnston, R Appugliese, M Kassam, P E Zuech, R L Hummel.   

Abstract

A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as a system controller, to coordinate the system timing and to manage the data transfer. The method used for analysis of the photographs to determine the velocity profiles is described. Examples are presented of instantaneous velocity profiles obtained from velocity waveforms that are similar to those of the femoral artery. In addition, application of the system for studying the relationship between Doppler ultrasound spectral recordings and flow velocity profiles is discussed.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2945500     DOI: 10.1007/bf02584271

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  7 in total

1.  The inlet length for oscillatory flow and its effects on the determination of the rate of flow in arteries.

Authors:  C C CHANG; H B ATABEK
Journal:  Phys Med Biol       Date:  1961-10       Impact factor: 3.609

2.  Comparison of CW Doppler ultrasound spectra with the spectra derived from a flow visualization model.

Authors:  J K Poots; K W Johnston; R S Cobbold; M Kassam
Journal:  Ultrasound Med Biol       Date:  1986-02       Impact factor: 2.998

3.  Development and evaluation of a hot-film velocity probe for cardiovascular studies.

Authors:  W A Seed; N B Wood
Journal:  Cardiovasc Res       Date:  1970-04       Impact factor: 10.787

4.  Development of pump system for experimental model simulation of blood flow in peripheral artery.

Authors:  T Kiyose; A Kusaba; M Kamori; K Inokuchi; Y Takamatsu
Journal:  Fukuoka Igaku Zasshi       Date:  1977-02

5.  Critical evaluation of continuous-wave Doppler probes for carotid studies.

Authors:  Y Douville; J W Arenson; K W Johnston; R S Cobbold; M Kassam
Journal:  J Clin Ultrasound       Date:  1983 Feb-Mar       Impact factor: 0.910

6.  Steady flow in a model of the human carotid bifurcation. Part II--laser-Doppler anemometer measurements.

Authors:  B K Bharadvaj; R F Mabon; D P Giddens
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

7.  [Qualitative and quantitative flow studies in a model of human renal arteries (author's transl)].

Authors:  D Liepsch; S Moravec
Journal:  Biomed Tech (Berl)       Date:  1979 Jul-Aug       Impact factor: 1.411

  7 in total
  3 in total

1.  Computer-controlled positive displacement pump for physiological flow simulation.

Authors:  D W Holdsworth; D W Rickey; M Drangova; D J Miller; A Fenster
Journal:  Med Biol Eng Comput       Date:  1991-11       Impact factor: 2.602

2.  Computer-controlled pulsatile pump system for physiological flow simulation.

Authors:  Y F Law; R S Cobbold; K W Johnston; P A Bascom
Journal:  Med Biol Eng Comput       Date:  1987-09       Impact factor: 2.602

3.  A novel roller pump for physiological flow.

Authors:  Albert Chong; Zhonghua Sun; Lennart van de Velde; Shirley Jansen; Michel Versluis; Michel M P J Reijnen; Erik Groot Jebbink
Journal:  Artif Organs       Date:  2020-03-25       Impact factor: 3.094

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.