Comparison of CW Doppler ultrasound spectra with the spectra derived from a flow visualization model.

J K Poots, K W Johnston, R S Cobbold, M Kassam.   

Abstract

The methods and results of a study to determine the accuracy of continuous wave (CW) Doppler spectral recordings by comparison to the spectra derived from the flow profiles photographed simultaneously in a pulsatile flow visualization model are reported in this paper. A pulsatile pump produced a flow velocity waveform, similar to that seen in the human femoral artery, in a quartz glass tube. The velocity profiles, which were made visible by using a photochromic dye/laser technique, were photographed, and at the same time the instantaneous Doppler spectra were recorded. A comparison of the Doppler data and the photographed profiles gave the following results. The Doppler spectrograms and those reconstructed from the flow visualization data were quite similar. Excellent agreement was observed between the instantaneous maximum and mean Doppler waveforms. Individual spectra showed some differences and these differences were quantified by the novel application of certain statistical shape descriptor coefficients that are based on the estimation of the higher order moments of the spectra. The Doppler spectra are generally more skewed towards higher frequencies, narrower, and more peaked than the flow visualization spectra. Analysis of the assumptions and various sources of error lead to the conclusion that the differences were probably caused by ultrasound beam nonuniformity and the effects of refraction, causing a reduction of the beam field response at the tube edges. It is concluded that provided certain precautions are taken in the measurement technique, the CW Doppler ultrasound spectra fairly accurately represent the true velocity profile.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2943068     DOI: 10.1016/0301-5629(86)90017-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Effect of ensemble averaging on amplitude and feature variabilities of Doppler spectrograms recorded in the lower limb arteries.

Authors:  L Allard; Y E Langlois; L G Durand; G O Roederer; G Cloutier
Journal:  Med Biol Eng Comput       Date:  1992-05       Impact factor: 2.602

2.  The effect of averaging cardiac Doppler spectrograms on the reduction of their amplitude variability.

Authors:  G Cloutier; L Allard; Z Guo; L G Durand
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

3.  Evaluation of guidewire path reproducibility.

Authors:  Sebastian Schafer; Kenneth R Hoffmann; Peter B Noël; Ciprian N Ionita; Jacek Dmochowski
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Doppler ultrasound spectral power density distribution: measurement artefacts in steady flow.

Authors:  R S Thompson; G K Aldis; I W Linnett
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

5.  A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

Authors:  K Poots; R S Cobbold; K W Johnston; R Appugliese; M Kassam; P E Zuech; R L Hummel
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.