Literature DB >> 29454740

A rapid point-of-care test for dengue virus-1 based on a lateral flow assay with a near-infrared fluorescent dye.

Lin Chen1, Huagui Wang2, Tongsheng Guo3, Chaohui Xiao3, Licheng Liu4, Xiaoguang Zhang5, Bo Liu3, Peiran Li3, Aixia Liu3, Bo Li3, Boan Li6, Yuanli Mao7.   

Abstract

Dengue fever is caused by the dengue virus (DENV), and DENV1 is the prevalent epidemic serotype in south China. A new lateral flow assay (LFA) based on a near-infrared (NIR) fluorescent dye was developed to detect anti-DENV1 IgG antibodies. DyLight-800 was used as the marker conjugated to goat anti-human IgG antibodies, and recombinant dengue type 1 envelope protein was used as the capture protein on the test line. Twenty samples from patients infected with DENV1 and 160 negative controls were analyzed using this new NIR-LFA. The results of the NIR-LFA were compared with the results of Panbio Dengue IgG ELISA and the Dengue Duo IgM/IgG Cassette. Nineteen confirmed DENV1-positive samples were identified by NIR-LFA, giving 95% (19/20) sensitivity. No significant differences existed in the results when the 20 primary clinical samples were analyzed using NIR-LFA, Panbio ELISA, and the Dengue Duo Cassette. However, NIR-LFA had a lower limit of detection than IgG ELISA and Duo IgM/IgG Cassette did when analyzing a 2-fold dilution series of the 19 samples positively identified by NIR-LFA. When incorporated with an NIR POCT device, the new NIR-LFA was rapid, easy to use, and highly sensitive in detecting DENV1, and has potential for application to clinical diagnosis.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DENV; Lateral flow assay; Near infrared; POCT

Mesh:

Substances:

Year:  2018        PMID: 29454740     DOI: 10.1016/j.jim.2018.02.005

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  2 in total

Review 1.  Biosensing strategies for the electrochemical detection of viruses and viral diseases - A review.

Authors:  Laís Canniatti Brazaca; Pãmyla Layene Dos Santos; Paulo Roberto de Oliveira; Diego Pessoa Rocha; Jéssica Santos Stefano; Cristiane Kalinke; Rodrigo Alejandro Abarza Muñoz; Juliano Alves Bonacin; Bruno Campos Janegitz; Emanuel Carrilho
Journal:  Anal Chim Acta       Date:  2021-03-12       Impact factor: 6.911

2.  Digital Pregnancy Test Powered by an Air-Breathing Paper-Based Microfluidic Fuel Cell Stack Using Human Urine as Fuel.

Authors:  Irma Lucia Vera-Estrada; Juan Manuel Olivares-Ramírez; Juvenal Rodríguez-Reséndiz; Andrés Dector; Jorge Domingo Mendiola-Santibañez; Diana María Amaya-Cruz; Adrían Sosa-Domínguez; David Ortega-Díaz; Diana Dector; Victor Manuel Ovando-Medina; Iveth Dalila Antonio-Carmona
Journal:  Sensors (Basel)       Date:  2022-09-02       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.