Literature DB >> 29445974

Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study.

Caroline Morbach1,2, Götz Gelbrich3,4, Margret Breunig1,2, Theresa Tiffe1,3, Martin Wagner1,3, Peter U Heuschmann3,4, Stefan Störk5,6.   

Abstract

Variability related to image acquisition and interpretation is an important issue of echocardiography in clinical trials. Nevertheless, there is no broadly accepted standard method for quality assessment of echocardiography in clinical research reports. We present analyses based on the echocardiography quality-assurance program of the ongoing STAAB cohort study (characteristics and course of heart failure stages A-B and determinants of progression). In 43 healthy individuals (mean age 50 ± 14 years; 18 females), duplicate echocardiography scans were acquired and mutually interpreted by one of three trained sonographers and an EACVI certified physician, respectively. Acquisition (AcV), interpretation (InV), and inter-observer variability (IOV; i.e., variability between the acquisition-interpretation sequences of two different observers), were determined for selected M-mode, B-mode, and Doppler parameters. We calculated Bland-Altman upper 95% limits of absolute differences, implying that 95% of measurement differences were smaller/equal to the given value: e.g. LV end-diastolic volume (mL): 25.0, 25.0, 27.9; septal e' velocity (cm/s): 3.03, 1.25, 3.58. Further, 90, 85, and 80% upper limits of absolute differences were determined for the respective parameters. Both, acquisition and interpretation, independently and sizably contributed to IOV. As such, separate assessment of AcV and InV is likely to aid in echocardiography training and quality-assurance. Our results further suggest to routinely determine IOV in clinical trials as a comprehensive measure of imaging quality. The derived 95, 90, 85, and 80% upper limits of absolute differences are suggested as reproducibility targets of future studies, thus contributing to the international efforts of standardization in quality-assurance.

Entities:  

Keywords:  Acquisition; Echocardiography; Observer; Quality; Reproducibility; Variability

Mesh:

Year:  2018        PMID: 29445974     DOI: 10.1007/s10554-018-1315-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  13 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Association between degenerative aortic valve disease and long-term exposure to cardiovascular risk factors: results of the longitudinal population-based KORA/MONICA survey.

Authors:  Jan Stritzke; Patrick Linsel-Nitschke; Marcello Ricardo Paulista Markus; Björn Mayer; Wolfgang Lieb; Andreas Luchner; Angela Döring; Wolfgang Koenig; Ulrich Keil; Hans-Werner Hense; Heribert Schunkert
Journal:  Eur Heart J       Date:  2009-07-16       Impact factor: 29.983

3.  Reproducibility in echocardiographic assessment of the left ventricular global and regional function, the HUNT study.

Authors:  Anders Thorstensen; Havard Dalen; Brage Høyem Amundsen; Svein Arne Aase; Asbjørn Stoylen
Journal:  Eur J Echocardiogr       Date:  2009-12-03

4.  Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study.

Authors:  Seisyou Kou; Luis Caballero; Raluca Dulgheru; Damien Voilliot; Carla De Sousa; George Kacharava; George D Athanassopoulos; Daniele Barone; Monica Baroni; Nuno Cardim; Jose Juan Gomez De Diego; Andreas Hagendorff; Christine Henri; Krasimira Hristova; Teresa Lopez; Julien Magne; Gonzalo De La Morena; Bogdan A Popescu; Martin Penicka; Tolga Ozyigit; Jose David Rodrigo Carbonero; Alessandro Salustri; Nico Van De Veire; Ralph Stephan Von Bardeleben; Dragos Vinereanu; Jens-Uwe Voigt; Jose Luis Zamorano; Erwan Donal; Roberto M Lang; Luigi P Badano; Patrizio Lancellotti
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-01-21       Impact factor: 6.875

Review 5.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

Authors:  Roberto M Lang; Luigi P Badano; Victor Mor-Avi; Jonathan Afilalo; Anderson Armstrong; Laura Ernande; Frank A Flachskampf; Elyse Foster; Steven A Goldstein; Tatiana Kuznetsova; Patrizio Lancellotti; Denisa Muraru; Michael H Picard; Ernst R Rietzschel; Lawrence Rudski; Kirk T Spencer; Wendy Tsang; Jens-Uwe Voigt
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-03       Impact factor: 6.875

Review 6.  Critical Review of Current Approaches for Echocardiographic Reproducibility and Reliability Assessment in Clinical Research.

Authors:  Anna Lisa Crowley; Eric Yow; Huiman X Barnhart; Melissa A Daubert; Robert Bigelow; Daniel C Sullivan; Michael Pencina; Pamela S Douglas
Journal:  J Am Soc Echocardiogr       Date:  2016-10-06       Impact factor: 5.251

7.  American Society of Echocardiography Cardiovascular Technology and Research Summit: a roadmap for 2020.

Authors:  Patricia A Pellikka; Pamela S Douglas; James G Miller; Theodore P Abraham; Rolf Baumann; Denis B Buxton; Benjamin F Byrd; Peter Chen; Nakela L Cook; Julius M Gardin; Gunnar Hansen; Hélène C Houle; Stefan Husson; Sanjiv Kaul; Allan L Klein; Roberto M Lang; Howard Leong-Poi; Hector Lopez; Tamer M Mahmoud; Sam Maslak; Marti L McCulloch; Steve Metz; Sherif F Nagueh; Alan S Pearlman; Philippe Pibarot; Michael H Picard; Thomas R Porter; David Prater; Rudy Rodriguez; Maurice E Sarano; Marielle Scherrer-Crosbie; Girish S Shirali; Albert Sinusas; Jack J Slosky; Lissa Sugeng; Anand Tatpati; Flordeliza S Villanueva; Olaf T von Ramm; Neil J Weissman; Shaun Zamani
Journal:  J Am Soc Echocardiogr       Date:  2013-04       Impact factor: 5.251

8.  The ventricular volume variability study of the Pediatric Heart Network: study design and impact of beat averaging and variable type on the reproducibility of echocardiographic measurements in children with chronic dilated cardiomyopathy.

Authors:  Steven D Colan; Girish Shirali; Renee Margossian; Dianne Gallagher; Karen Altmann; Charles Canter; Shan Chen; Fraser Golding; Elizabeth Radojewski; Michael Camitta; Michael Carboni; Jack Rychik; Mario Stylianou; Lloyd Y Tani; Elif Seda Selamet Tierney; Yanli Wang; Lynn A Sleeper
Journal:  J Am Soc Echocardiogr       Date:  2012-06-05       Impact factor: 5.251

9.  Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function.

Authors:  J E Otterstad; G Froeland; M St John Sutton; I Holme
Journal:  Eur Heart J       Date:  1997-03       Impact factor: 29.983

10.  Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography.

Authors:  Carly Jenkins; Kristen Bricknell; Lizelle Hanekom; Thomas H Marwick
Journal:  J Am Coll Cardiol       Date:  2004-08-18       Impact factor: 24.094

View more
  10 in total

1.  Segment-specific association of carotid-intima-media thickness with cardiovascular risk factors - findings from the STAAB cohort study.

Authors:  Lara Müller-Scholden; Jan Kirchhof; Caroline Morbach; Margret Breunig; Rudy Meijer; Viktoria Rücker; Theresa Tiffe; Tino Yurdadogan; Martin Wagner; Götz Gelbrich; Michiel L Bots; Stefan Störk; Peter U Heuschmann
Journal:  BMC Cardiovasc Disord       Date:  2019-04-04       Impact factor: 2.298

2.  Speckle tracking derived reference values of myocardial deformation and impact of cardiovascular risk factors - Results from the population-based STAAB cohort study.

Authors:  Caroline Morbach; Bettina N Walter; Margret Breunig; Dan Liu; Theresa Tiffe; Martin Wagner; Götz Gelbrich; Peter U Heuschmann; Stefan Störk
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

3.  Plasma protein thiolation index (PTI) as a potential biomarker for left ventricular hypertrophy in humans.

Authors:  Begoña Quintana-Villamandos; Irene González Del Pozo; Laia Pazó-Sayós; Jose María Bellón; Álvaro Pedraz-Prieto; Ángel G Pinto; Emilio Delgado-Baeza
Journal:  PLoS One       Date:  2019-05-08       Impact factor: 3.240

4.  Rationale and design of the cardiovascular status in patients with endogenous cortisol excess study (CV-CORT-EX): a prospective non-interventional follow-up study.

Authors:  Kristina Ehrlich; Caroline Morbach; Theresa Reiter; Peter Ulrich Heuschmann; Anke Hannemann; Martin Fassnacht; Stefan Störk; Stefanie Hahner; Timo Deutschbein
Journal:  BMC Endocr Disord       Date:  2021-01-08       Impact factor: 2.763

5.  Prevalence and determinants of systolic and diastolic cardiac dysfunction and heart failure in acute ischemic stroke patients: The SICFAIL study.

Authors:  Peter U Heuschmann; Felipe A Montellano; Kathrin Ungethüm; Viktoria Rücker; Silke Wiedmann; Daniel Mackenrodt; Anika Quilitzsch; Timo Ludwig; Peter Kraft; Judith Albert; Caroline Morbach; Stefan Frantz; Stefan Störk; Karl Georg Haeusler; Christoph Kleinschnitz
Journal:  ESC Heart Fail       Date:  2020-12-22

6.  CHARACTERISTICS OF THE FOVEAL MICROVASCULATURE IN CHILDREN WITH MARFAN SYNDROME: An Optical Coherence Tomography Angiography Study.

Authors:  Hui Chen; Kit Yee Ng; Songshan Li; Guangming Jin; Qianzhong Cao; Zhangkai Lian; Xiaoling Luo; Xiaoyan Ding; Danying Zheng
Journal:  Retina       Date:  2022-01-01       Impact factor: 4.256

7.  Left Ventricular Remodeling and Myocardial Work: Results From the Population-Based STAAB Cohort Study.

Authors:  Floran Sahiti; Caroline Morbach; Vladimir Cejka; Judith Albert; Felizitas A Eichner; Götz Gelbrich; Peter U Heuschmann; Stefan Störk
Journal:  Front Cardiovasc Med       Date:  2021-06-11

8.  Retinal and Choroidal Vasculature in Patients with Marfan Syndrome.

Authors:  Matteo Di Marino; Massimo Cesareo; Gianluca Aloe; Carlo Nucci; Clarissa Giannini; Alessio Martucci; Francesco Aiello; Calogera Pisano; Giovanni Ruvolo; Raffaele Mancino
Journal:  Transl Vis Sci Technol       Date:  2020-08-04       Impact factor: 3.283

9.  Effectiveness of real-time tele-ultrasound for echocardiography in resource-limited medical teams.

Authors:  Tomohiro Kaneko; Nobuyuki Kagiyama; Yutaka Nakamura; Tomomi Hirasawa; Azusa Murata; Ryoko Morimoto; Sakiko Miyazaki; Tohru Minamino
Journal:  J Echocardiogr       Date:  2021-08-04

10.  Impact of cardiovascular risk factors on myocardial work-insights from the STAAB cohort study.

Authors:  Peter U Heuschmann; Stefan Störk; Floran Sahiti; Caroline Morbach; Vladimir Cejka; Theresa Tiffe; Martin Wagner; Felizitas A Eichner; Götz Gelbrich
Journal:  J Hum Hypertens       Date:  2021-03-02       Impact factor: 3.012