Turbulent shear stress measurements in the vicinity of aortic heart valve prostheses.

A P Yoganathan, Y R Woo, H W Sung.   

Abstract

A two dimensional laser Doppler anemometer system has been used to measure the turbulent shear fields in the immediate downstream vicinity of a variety of mechanical and bioprosthetic aortic heart valves. The measurements revealed that all the mechanical valves studied, created regions of elevated levels of turbulent shear stress during the major portion of systole. The tissue bioprostheses also created elevated levels of turbulence, but they were confined to narrow regions in the bulk of the flow field. The newer generation of bioprostheses create turbulent shear stresses which are considerably lower than those created by the older generation tissue valve designs. All the aortic valves studied (mechanical and tissue) create turbulent shear stress levels which are capable of causing sub-lethal and/or lethal damage to blood elements.

Mesh:

Year:  1986        PMID: 2943742     DOI: 10.1016/0021-9290(86)90020-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  16 in total

1.  Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

Authors:  R Botnar; E Nagel; M B Scheidegger; E M Pedersen; O Hess; P Boesiger
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

2.  Hemolysis after mitral valve replacement with mechanical valve prostheses.

Authors:  M Ninomiya; K Yagyu; Y Kaneko; Y Kotsuka; S Takamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-04

3.  Near valve flows and potential blood damage during closure of a bileaflet mechanical heart valve.

Authors:  L H Herbertson; S Deutsch; K B Manning
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

4.  Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV.

Authors:  Chris Hutchison; Pierre Sullivan; C Ross Ethier
Journal:  Med Biol Eng Comput       Date:  2010-11-16       Impact factor: 2.602

5.  The effect of implantation orientation of a bileaflet mechanical heart valve on kinematics and hemodynamics in an anatomic aorta.

Authors:  Iman Borazjani; Fotis Sotiropoulos
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

6.  Reynolds shear stress for textile prosthetic heart valves in relation to fabric design.

Authors:  David L Bark; Atieh Yousefi; Marcio Forleo; Antoine Vaesken; Frederic Heim; Lakshmi P Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2016-02-06

7.  Dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase: effect of squeeze film.

Authors:  C Gill-Jeong; K B Chandran
Journal:  Ann Biomed Eng       Date:  1995 Mar-Apr       Impact factor: 3.934

8.  Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.

Authors:  C S Lee; K B Chandran
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

9.  Instantaneous back flow through peripheral clearance of Medtronic Hall tilting disc valve at the moment of closure.

Authors:  C S Lee; K B Chandran
Journal:  Ann Biomed Eng       Date:  1994 Jul-Aug       Impact factor: 3.934

10.  Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.

Authors:  Danny Bluestein; Gaurav Girdhar; Shmuel Einav; Marvin J Slepian
Journal:  J Biomech       Date:  2012-12-06       Impact factor: 2.712

View more