Lihua Chen1,2, Daihong Liu1, Jiuquan Zhang1, Bing Xie1, Xiaoyue Zhou3, Robert Grimm4, Xuequan Huang1, Jian Wang1, Li Feng5. 1. Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, China. 2. Department of Radiology, PLA 101st Hospital, Wuxi Jiangsu, China. 3. MR Collaboration, North East Asia, Siemens Healthcare, Shanghai, China. 4. Siemens Healthcare, Erlangen, Germany. 5. Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.
Abstract
BACKGROUND: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been shown to be a promising technique for assessing lung lesions. However, DCE-MRI often suffers from motion artifacts and insufficient imaging speed. Therefore, highly accelerated free-breathing DCE-MRI is of clinical interest for lung exams. PURPOSE: To test the performance of rapid free-breathing DCE-MRI for simultaneous qualitative and quantitative assessment of pulmonary lesions using Golden-angle RAdial Sparse Parallel (GRASP) imaging. STUDY TYPE: Prospective. POPULATION: Twenty-six patients (17 males, mean age = 55.1 ± 14.4) with known pulmonary lesions. FIELD STRENGTH/SEQUENCE: 3T MR scanner; a prototype fat-saturated, T1 -weighted stack-of-stars golden-angle radial sequence for data acquisition and a Cartesian breath-hold volumetric-interpolated examination (BH-VIBE) sequence for comparison. ASSESSMENT: After a dual-mode GRASP reconstruction, one with 3-second temporal resolution (3s-GRASP) and the other with 15-second temporal resolution (15s-GRASP), all GRASP and BH-VIBE images were pooled together for blind assessment by two experienced radiologists, who independently scored the overall image quality, lesion delineation, overall artifact level, and diagnostic confidence of each case. Perfusion analysis was performed for the 3s-GRASP images using a Tofts model to generate the volume transfer coefficient (Ktrans ) and interstitial volume (Ve ). STATISTICAL TESTS: Nonparametric paired two-tailed Wilcoxon signed-rank test; Cohen's kappa; unpaired Student's t-test. RESULTS: 15s-GRASP achieved comparable image quality with conventional BH-VIBE (P > 0.05), except for the higher overall artifact level in the precontrast phase (P = 0.018). The Ktrans and Ve in inflammation were higher than those in malignant lesions (Ktrans : 0.78 ± 0.52 min-1 vs. 0.37 ± 0.22 min-1 , P = 0.020; Ve : 0.36 ± 0.16 vs. 0.26 ± 0.1, P = 0.177). Also, the Ktrans and Ve in malignant lesions were also higher than those in benign lesions (Ktrans : 0.37 ± 0.22 min-1 vs. 0.04 ± 0.04 min-1 , P = 0.001; Ve : 0.26 ± 0.12 vs. 0.10 ± 0.00, P = 0.063). DATA CONCLUSION: This feasibility study demonstrated the performance of high spatiotemporal resolution free-breathing DCE-MRI of the lung using GRASP for qualitative and quantitative assessment of pulmonary lesions. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:459-468.
BACKGROUND: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been shown to be a promising technique for assessing lung lesions. However, DCE-MRI often suffers from motion artifacts and insufficient imaging speed. Therefore, highly accelerated free-breathing DCE-MRI is of clinical interest for lung exams. PURPOSE: To test the performance of rapid free-breathing DCE-MRI for simultaneous qualitative and quantitative assessment of pulmonary lesions using Golden-angle RAdial Sparse Parallel (GRASP) imaging. STUDY TYPE: Prospective. POPULATION: Twenty-six patients (17 males, mean age = 55.1 ± 14.4) with known pulmonary lesions. FIELD STRENGTH/SEQUENCE: 3T MR scanner; a prototype fat-saturated, T1 -weighted stack-of-stars golden-angle radial sequence for data acquisition and a Cartesian breath-hold volumetric-interpolated examination (BH-VIBE) sequence for comparison. ASSESSMENT: After a dual-mode GRASP reconstruction, one with 3-second temporal resolution (3s-GRASP) and the other with 15-second temporal resolution (15s-GRASP), all GRASP and BH-VIBE images were pooled together for blind assessment by two experienced radiologists, who independently scored the overall image quality, lesion delineation, overall artifact level, and diagnostic confidence of each case. Perfusion analysis was performed for the 3s-GRASP images using a Tofts model to generate the volume transfer coefficient (Ktrans ) and interstitial volume (Ve ). STATISTICAL TESTS: Nonparametric paired two-tailed Wilcoxon signed-rank test; Cohen's kappa; unpaired Student's t-test. RESULTS: 15s-GRASP achieved comparable image quality with conventional BH-VIBE (P > 0.05), except for the higher overall artifact level in the precontrast phase (P = 0.018). The Ktrans and Ve in inflammation were higher than those in malignant lesions (Ktrans : 0.78 ± 0.52 min-1 vs. 0.37 ± 0.22 min-1 , P = 0.020; Ve : 0.36 ± 0.16 vs. 0.26 ± 0.1, P = 0.177). Also, the Ktrans and Ve in malignant lesions were also higher than those in benign lesions (Ktrans : 0.37 ± 0.22 min-1 vs. 0.04 ± 0.04 min-1 , P = 0.001; Ve : 0.26 ± 0.12 vs. 0.10 ± 0.00, P = 0.063). DATA CONCLUSION: This feasibility study demonstrated the performance of high spatiotemporal resolution free-breathing DCE-MRI of the lung using GRASP for qualitative and quantitative assessment of pulmonary lesions. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:459-468.
Authors: Johan Coolen; Johan Vansteenkiste; Frederik De Keyzer; Herbert Decaluwé; Walter De Wever; Christophe Deroose; Christophe Dooms; Eric Verbeken; Paul De Leyn; Vincent Vandecaveye; Dirk Van Raemdonck; Kristiaan Nackaerts; Steven Dymarkowski; Johny Verschakelen Journal: Eur Radiol Date: 2013-10-31 Impact factor: 5.315
Authors: Hersh Chandarana; Li Feng; Justin Ream; Annie Wang; James S Babb; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo Journal: Invest Radiol Date: 2015-11 Impact factor: 6.016
Authors: Damon Kim; Thomas Elgeti; Tobias Penzkofer; Ingo G Steffen; Laura J Jensen; Stefan Schwartz; Bernd Hamm; Sebastian N Nagel Journal: Eur Radiol Date: 2020-08-21 Impact factor: 5.315
Authors: Sydney B Montesi; Iris Y Zhou; Lloyd L Liang; Subba R Digumarthy; Sarah Mercaldo; Nathaniel Mercaldo; Ravi T Seethamraju; Bruce R Rosen; Peter Caravan Journal: ERJ Open Res Date: 2021-11-08
Authors: Lea Behrendt; Laurie J Smith; Andreas Voskrebenzev; Filip Klimeš; Till F Kaireit; Gesa H Pöhler; Agilo L Kern; Cristian Crisosto Gonzalez; Anna-Maria Dittrich; Helen Marshall; Katharina Schütz; Paul J C Hughes; Pierluigi Ciet; Harm A W M Tiddens; Jim M Wild; Jens Vogel-Claussen Journal: Pulm Circ Date: 2022-04-05 Impact factor: 2.886
Authors: Marieke A Stammes; Ji Hyun Lee; Lisette Meijer; Thibaut Naninck; Lara A Doyle-Meyers; Alexander G White; H Jacob Borish; Amy L Hartman; Xavier Alvarez; Shashank Ganatra; Deepak Kaushal; Rudolf P Bohm; Roger le Grand; Charles A Scanga; Jan A M Langermans; Ronald E Bontrop; Courtney L Finch; JoAnne L Flynn; Claudia Calcagno; Ian Crozier; Jens H Kuhn Journal: Trends Mol Med Date: 2021-12-07 Impact factor: 15.272