| Literature DB >> 29426961 |
Nicole C M Visser1, Anneke A M van der Wurff2, Johanna M A Pijnenborg3, Leon F A G Massuger3, Johan Bulten4, Iris D Nagtegaal4.
Abstract
The aim of this study was to define the concordance between tissue microarrays (TMAs) of different sizes and whole slide for 15 different antibodies in endometrial cancer and study the use of TMAs in preoperative endometrial samples. Cores of preoperative and hysterectomy specimens of 14 endometrial cancer and three atypical hyperplasia cases were collected in TMA blocks. Two 0.6-mm and two 2.0-mm cores were used from each sample. Different antibodies were tested in TMAs and compared with results of whole slides of hysterectomy. Tested antibodies were as follows: ER, PR, p53, Ki-67, MLH1, PMS2, MSH2, MSH6, ARID1A, stathmin, IMP3, L1CAM, PTEN, β-catenin, and p16. Seventeen cases with four cores per paraffin block (both 0.6 and 2.0 mm in duplicate) and 15 different antibodies resulted in a total of 1020 cores for both preoperative and hysterectomy specimen. Overall, 2.0-mm cores were more assessable for evaluation than 0.6-mm cores (96.0 versus 79.5%, p < 0.01). For most antibodies, a substantial to good agreement between hysterectomy TMA and whole slide was present, with lowest agreement for p16 and stathmin and perfect agreement for mismatch repair proteins. Preoperative TMAs showed for most antibodies moderate to perfect agreement with hysterectomy TMAs. In conclusion, 2.0-mm cores are the preferred size for immunohistochemical studies in endometrial cancer. For all tested antibodies, TMAs are a good alternative for whole slide analysis in scientific studies with large patient cohorts, even in preoperative endometrial samples. However, caution is required for interpretation of TMA results of p16 and stathmin.Entities:
Keywords: Biomarkers; Endometrial cancer; Endometrial sampling; Immunohistochemistry; Tissue microarray
Mesh:
Substances:
Year: 2018 PMID: 29426961 PMCID: PMC5887002 DOI: 10.1007/s00428-017-2289-6
Source DB: PubMed Journal: Virchows Arch ISSN: 0945-6317 Impact factor: 4.064
Antibodies used in this study
| Antibody | Staining pattern | Clone | Antigen retrieval | Dilution | Source | Interobserver variability (kappa) |
|---|---|---|---|---|---|---|
| ER | Nuclear | SP1 | EDTA pH 9 | 1:80 | Immunologic | 0.959 |
| PR | Nuclear | PgR636 | EDTA pH 9 | 1:500 | Dako | 0.961 |
| MLH1 | Nuclear | G168-15 | EDTA pH 9 | 1:40 | BD | 0.894 |
| PMS2 | Nuclear | A16-4 | EDTA pH 9 | 1:100 | BD | 0.800 |
| MSH2 | Nuclear | GB12 | EDTA pH 9 | 1:20 | Calbiochem | 0.848 |
| MSH6 | Nuclear | EPR3945 | EDTA pH 9 | 1:1000 | Abcam | 0.763 |
| PTEN | Nuclear and cytoplasmic | 6H2.1 | EDTA pH 9 | 1:100 | Dako | 0.724 |
| IMP3 | Cytoplasmic | 69.1 | EDTA pH 9 | 1:50 | Dako | 0.912 |
| β-Catenin | Membranous and cytoplasmic | 14/β-catenin | EDTA pH 9 | 1:200 | BD | 0.911 |
| L1CAM | Membranous | 14.10 | EDTA pH 9 | 1:100 | BioLegend | 0.921 |
| Ki-67 | Nuclear | MIB-1 | Citrate pH 6.0 | 1:40 | Dako | 0.998 |
| ARID1A | Nuclear | HPA005456 | Citrate pH 6.0 | 1:100 | Sigma | 0.796 |
| Stathmin | Cytoplasmic | 3351 | Citrate pH 6.0 | 1:50 | Cell Signaling | 0.824 |
| P53 | Nuclear | DO-7 | Citrate pH 6.7 | 1:200 | Immunologic | 0.901 |
| P16 | Nuclear and cytoplasmic | MX007 | HIER pH 8.0 | 1:60 | Immunologic | 0.779 |
Fig. 1Strength of agreement between two cores of the same size (kappa statistics). Green indicates almost perfect agreement, red indicates poor agreement
Fig. 2Preoperative versus hysterectomy TMA for 0.6 mm (a) and 2.0 mm (b) and TMA versus whole slide of hysterectomy for 0.6-mm (c) and 2.0-mm cores (d). Green indicates no difference, red indicates difference, and blue indicates not assessable cores. Percentages represent the percentage of cores with a difference between respespectively preoperative and hysterectomy TMA score and between TMA and whole slide of hysterectomy
Fig. 3TMA versus whole slide of hysterectomy. a Strength of agreement between TMA and whole slide of hysterectomy (kappa statistics). b Case with discrepancy between whole slide and 0.6 mm TMA for p16 (two 0.6-mm core holes marked with an asterisk). Whole slide showing positive staining (scorings index 6), concordant positive 2.0-mm cores (combined scorings index 6) and discrepant negative 0.6-mm cores (combined scorings index 3)
Fig. 4Absolute difference in Ki-67 score between TMA and whole slide (ref.) per case. Each bar represents a case, with in black the 0.6-mm cores and in gray 2.0-mm cores. In the most right column, the median difference in Ki-67 for all cases, separated by core diameter