Literature DB >> 29426530

Flow injection spectrophotometric determination of V(V) involving on-line separation using a poly(vinylidene fluoride-co-hexafluoropropylene)-based polymer inclusion membrane.

Mohammad Reza Yaftian1, M Inês G S Almeida2, Robert W Cattrall2, Spas D Kolev3.   

Abstract

A poly(vinylidene fluoride-co-hexafluoropropylene)-based polymer inclusion membrane (PIM) using Cyphos® IL 101 (i.e. trihexyl(tetradecyl)phosphonium chloride) as the carrier and 2-nitrophenyl octyl ether as a plasticizer in a mass ratio of 55/35/10 was employed for the on-line extractive separation of V(V) prior to its spectrophotometric determination in a flow injection analysis (FIA) system using xylenol orange as the colorimetric reagent. The selectivity of the membrane allowed the determination of V(V) in sulfate solutions in the presence of a variety of cations and anions. The interference of molybdenum(VI) was eliminated by off-line extraction using the same PIM. A univariate sequential optimization of the newly developed FIA system was conducted and under optimal conditions the system is characterized by a linear concentration range of 0.5-8.0mgL-1, detection limit of 0.08mgL-1 and sample throughput of 4h-1. The relative standard deviation at the 3mgL-1 level of V(V) was 2.9% based on 8 replicate determinations. The membrane was stable, which was reflected by the standard deviation value for determinations over three consecutive days (24 determinations of 3mgL-1 V(V)) of 3.6%. The newly developed FIA system was applied to the determination of V(V) in water and dietary supplements samples and a good agreement with inductively coupled plasma optical emission spectrometry was observed.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cyphos® IL 101; Determination of V(V); Flow Injection Analysis (FIA); PVDF-HFP; Polymer Inclusion Membrane (PIM)

Mesh:

Substances:

Year:  2018        PMID: 29426530     DOI: 10.1016/j.talanta.2018.01.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Determination of Cadmium (II) in Aqueous Solutions by In Situ MID-FTIR-PLS Analysis Using a Polymer Inclusion Membrane-Based Sensor: First Considerations.

Authors:  René González-Albarrán; Josefina de Gyves; Eduardo Rodríguez de San Miguel
Journal:  Molecules       Date:  2020-07-29       Impact factor: 4.411

2.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

3.  On the Potential of a Poly(vinylidenefluoride-co-hexafluoropropylene) Polymer Inclusion Membrane Containing Aliquat® 336 and Dibutyl Phthalate for V(V) Extraction from Sulfate Solutions.

Authors:  Salar Bahrami; Leila Dolatyari; Hassan Shayani-Jam; Mohammad Reza Yaftian; Spas D Kolev
Journal:  Membranes (Basel)       Date:  2022-01-14