Takashi Ono1, Masaharu Iida1, Toshihiro Sakisaka2, Keiichiro Minami3, Kazunori Miyata1. 1. Miyata Eye Hospital, 6-3 Kurahara-cho, Miyakonojo, Miyazaki, 885-0051, Japan. 2. Department of Ophthalmology, University of Tokyo, Tokyo, Japan. 3. Miyata Eye Hospital, 6-3 Kurahara-cho, Miyakonojo, Miyazaki, 885-0051, Japan. minami@miyata-med.ne.jp.
Abstract
PURPOSE: To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. STUDY DESIGN: Retrospective case series. METHODS: Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. RESULTS: Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy. CONCLUSIONS: Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.
PURPOSE: To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. STUDY DESIGN: Retrospective case series. METHODS: Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. RESULTS: Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy. CONCLUSIONS: Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.
Authors: Shao Yunliang; Huang Yuqiang; Liu Ying-Peng; Zhang Ming-Zhi; Dennis S C Lam; Srinivas K Rao Journal: Cornea Date: 2007-02 Impact factor: 2.651
Authors: Paulo Fernandes; José M González-Méijome; David Madrid-Costa; Teresa Ferrer-Blasco; Jorge Jorge; Robert Montés-Micó Journal: J Refract Surg Date: 2011-06-30 Impact factor: 3.573