Literature DB >> 29409487

Heterogeneous pattern of differences in respiratory parameters between elderly with either good or poor FEV1.

Stefan Karrasch1,2,3, Jürgen Behr4,5, Rudolf M Huber5,6, Dennis Nowak7,5, Annette Peters8, Stefan Peters7, Rolf Holle9, Rudolf A Jörres7,5, Holger Schulz10,5.   

Abstract

BACKGROUND: The relationship of spirometric values to other respiratory and functional parameters in advanced age is not well studied. We assessed this relationship in elderly subjects with either good or poor spirometric parameters to reveal whether different domains of lung function show comparable differences between the two groups.
METHODS: Among subjects of the population-based KORA-Age cohort (n = 935, 65-90y; 51% male) two groups were selected from either the lower (LED; n = 51) or the upper (UED; n = 72) end of the FEV1 distribution. All subjects did not have a history of lung disease and were non-smokers at the time of the study. Measurements included spirometry, body plethysmography, diffusing capacity for NO and CO, respiratory pump function and exhaled NO (FeNO). In addition, 6-min walking distance as a functional overall measure, as well as telomere length of blood leukocytes and serum 8-hydroxydeoxyguanosine (8-OHdG) as potential markers of overall biological ageing and stress were determined.
RESULTS: In the majority of parameters, LED subjects showed significantly impaired values compared to UED subjects. Differences in spirometric parameters, airway resistance and respiratory pump function ranged between 10% and more than 90% in terms of predicted values. In contrast, volume-related CO and NO diffusing capacity showed differences between groups of lower than 5%, while telomere length, 8-OHdG and FeNO were similar. This was reflected in the differences in "functional age" as derived from prediction equations.
CONCLUSIONS: In elderly subjects without a history of lung disease differences in spirometric parameters were associated with differences in other lung-mechanical parameters including body plethysmography but not with differences in volume-corrected gas exchange measures. Thus, the concept of a general "lung age" as suggested by the widespread use of this term in connection with spirometry should be considered with caution.

Entities:  

Keywords:  Body plethysmography; Diffusing capacity; Spirometry

Mesh:

Substances:

Year:  2018        PMID: 29409487      PMCID: PMC5801692          DOI: 10.1186/s12890-018-0582-z

Source DB:  PubMed          Journal:  BMC Pulm Med        ISSN: 1471-2466            Impact factor:   3.317


Background

In advanced age, spirometric indices show a large inter-individual variability within the general population even after accounting for age and determinants like sex, height and ethnicity, and for several parameters the coefficient of variation even increases with age [1]. The relationship between the functional indices as measured in the same lung-healthy subjects has not been extensively studied. This is of interest since low spirometric values are often used as an indicator of a reduced functional state of the whole respiratory system, particularly by deriving an estimated “lung age” e.g. to support smoking cessation [2]. In fact, however, it is unclear whether this notion is adequate in the sense that various functional parameters of the lung show low values. This would have to be expected with a common process of biological aging or premature aging. To answer this question a comparison of different domains of parameters is needed. Ideally, this requires a logitudinal analysis but at least the comparison of different functional domains should be possible in a sample of age-matched elderly subjects. We therefore investigated in subjects of advanced age who were free of lung disease according to their clinical history, whether various functional indices show parallel differences indicative of a general state of the respiratory system that could be related to aging. For this purpose we analyzed the relationships between forced expiratory volume in 1 s (FEV1), static lung volumes, airway conductance, respiratory pump function, pulmonary gas exchange, exhaled biomarkers, systemic oxidative stress and cell-biological age, as well as general physical capacity. The study population comprised two subgroups of the KORA-Age cohort who had been selected based on their percent predicted values of FEV1 either being at the upper or the lower end of the distribution.

Methods

Spirometry was performed in the KORA study center (Augsburg, Germany) within the frame of the KORA-Age study conducted in 2009–10 [3]. The study was approved by the Ethics Committee of the Bavarian Medical Association, and its details have been described previously [4]. Briefly, in 935 individuals aged 65–90 years from the Augsburg region spirometric measurements were performed in line with ATS/ERS recommendations [5], and 840 subjects gave their written consent to be contacted to participate in the current sub-study, for which 200 individuals were selected from the upper and lower tails of the FEV1%pred distribution based on reference equations of the lung-healthy population of the Augsburg region [4]. Subjects were further examined at the University Hospital of the Ludwig-Maximilians-Universität in Munich: 104 with high (upper end of distribution, UED) and 96 with low (lower end of distribution, LED) FEV1%pred. The examination focused on the respiratory system but also covered biomarkers and physical capacity. For the present analysis, current smokers and subjects with symptoms of chronic bronchitis or a respiratory infection within 3 weeks prior to examination were excluded. Non-smoking status was defined via self-report; additionally an exhaled carbon monoxide value of < 7 ppm was required [6]. These criteria led to an analysis sample of n = 72 (69% of total) in the upper and n = 51 (53%) in the lower group. A detailed description of the methods is given in Additional file 1. According to current guidelines, the following assessments were performed and parameters obtained: spirometry (FEV1, FVC, expiratory flow rates) [5], body plethysmography (airway conductance (Gaw), specific airway conductance (sGaw), total lung capacity (TLCpleth), intrathoracic gas volume (ITGV), residual volume (RV)) [7, 8], determination of CO and NO uptake of the lung (transfer factors TLCO, TLNO, transfer coefficients KCO, KNO; alveolar volume (VA), TLC by helium dilution (TLCHe)) [9], measurements of mouth occlusion pressure (0.1 s after the onset of tidal inspiration (P01), peak maximal static inspiratory mouth occlusion pressure (PImax)) [10], exhaled carbon monoxide (eCO) and exhaled nitric oxide at 50 ml/s (FeNO) [11]. Furthermore, a 6-min walk test was performed [12]. The telomere length of circulating leukocytes [13] and the serum level of 8-hydroxydeoxyguanosine (8-OHdG) were assessed from samples collected in the KORA study centre in Augsburg.

Data analysis

Group comparisons were performed as Student’s t-test if not stated otherwise. The robustness of results was tested with analysis of covariance (ANCOVA) and different confounders. Similarly, the associations of the functional indices with telomere length or 8-OHdG were examined using multiple linear regression analysis, with chronological age and sex as confounders. Statistical analyses were done using the software packages Statgraphics (Statpoint Technologies, Inc., Warrenton, VA) and SPSS Statistics 23 (IBM Corp., Armonk, NY, USA). Statistical significance was assumed at a level of 0.05. For the different lung function indices and 6MWD the following reference values were used: Quanjer et al. for spirometric parameters [1], Koch et al. for plethysmographic parameters [14], van der Lee et al. for pulmonary gas exchange [15], Enright et al. for PImax [16], and Enright & Sherrill for 6MWD [17].

Results

Baseline characteristics

The anthropometric characteristics of the two study groups are given in Table 1. There were no significant differences between UED and LED subjects regarding age, height and sex. However, the percentage of former smokers was higher in the LED group; in former smokers the number of pack years showed a tendency to be higher in the LED vs. UED group, but without statistically significant difference. Weight and body mass index (BMI) were slightly higher in the LED group (p < 0.01 each). The prevalences of cardiovascular diseases, diabetes and arthritis were similar; neurological diseases were only present in 4 subjects of the LED group.
Table 1

Characteristics of the study population

ParameterUED groupLED groupMean difference (UED-LED)95% CI of differencep-value for difference
Mean ± SDMedian (25%; 75%)Mean ± SDMedian (25%; 75%)LowerUpper
Number7251nananana
Sex, m/f28 / 4427 / 24nanana0.123a
Age, years76.8 ± 6.476.5 (71.3; 81.9)77.8 ± 7.277.6 (70.6; 83.9)−1.0−3.51,50.425
Height, m1.63 ± 0.091.63 (1.56; 1.70)1.64 ± 0.091.64 (1.57; 1.71)−0.00− 0.040.030.793
Weight, kg73.1 ± 10.272.9 (65.3; 81.0)79.6 ± 13.378.9 (69.3; 88.6)−6.4−10.8−2.0 0.005
BMI, kg/m227.5 ± 3.927.2 (25.1; 29.5)29.7 ± 4.428.6 (26.9; 32.2)−2.2−3.7−0.6 0.006
Former smokers, n (percentage)21 (29.2%)26 (51.0%)nanana 0.014 a
Pack years in former smokers, years14.6 ± 17.09.4 (1.5; 21.0)20.5 ± 20.812.2 (1.5; 36.6)−5.9−17.45.70.592b
Diseases, n (percentage)
 Cardiovascular diseases54 (75.0%)44 (86.3%)nanana0.126a
 Diabetes8 (11.3%)8 (15.7%)nanana0.476a
 Neurological diseases0 (0.0%)4 (7.8%)nananana
 Arthritis5 (6.9%)8 (15.7%)nanana0.120a

aChi-Square test, bMann-Whitney U test

p-values below 0.05 are shown in bold

Characteristics of the study population aChi-Square test, bMann-Whitney U test p-values below 0.05 are shown in bold

Spirometry

Data on spirometry are given in Table 2. Corresponding to the selection criterion for the groups, LED subjects showed lower mean FEV1 and FVC (difference of predicted values between groups Δ = 39.4%pred and Δ = 25.4%pred, respectively; p < 0.001 each) as well as a lower FEV1/FVC ratio (Δ = 10.7%). If the LLN criterion for FEV1/FVC [18] was applied, 37.3% of subjects from the LED group showed airflow limitation, in the absence of respiratory symptoms or a history of respiratory disease.
Table 2

Spirometric parameters

ParameterUED groupLED groupMean difference (UED-LED)95% CI of differencep-value for difference
NumberMean ± SDMedian (25%; 75%)NumberMean ± SDMedian (25%; 75%)LowerUpper
FEV1%pred72124.9 ± 10.3124.6 (116.9; 131.4)5185.5 ± 10.985.1 (77.1; 91.4)39.435.543.3 < 0.001
FVC %pred72127.2 ± 10.9129.8 (119.3; 134.4)51101.8 ± 13.0102.0 (95.6; 108.8)25.421.029.8 < 0.001
FEV1/FVC %pred7297.5 ± 6.297.7 (92.7; 102.3)5183.9 ± 10.484.4 (78.3; 91.0)13.610.416.9 < 0.001
FEF25–75%pred72124.7 ± 34.8120.4 (99.3; 148.8)4956.1 ± 23.649.2 (39.5; 65.0)69.859.380.2 < 0.001
FEF75%pred72168.0 ± 66.3159.7 (118.3; 204.9)4974.1 ± 39.565.5 (49.2; 86.8)93.974.8113.0 < 0.001
FEV1 z-score721.465 ± 0.5871.433 (0.991; 1.862)51−0.819 ± 0.610−0.847 (−1.288; −0.527)2.2842.0682.500 < 0.001
FVC z-score721.514 ± 0.5791.629 (1.124; 1.889)510.101 ± 0.7280.112 (− 0.270; 0.524)1.4131.1801.647 < 0.001
FEV1/FVC z-score72−0.221 ± 0.579−0.200 (− 0.654; 0.230)51−1.389 ± 0.857−1.349 (− 1.953; − 0.798)1.1680.9111.424 < 0.001
FEF25–75 z-score720.479 ± 0.7020.451 (− 0.014; 0.990)49− 1.229 ± 0.721−1.343 (− 1.721; − 0.955)1.7091.4481.969 < 0.001
FEF75 z-score720.697 ± 0.6140.752 (0.274; 1.108)49− 0.658 ± 0.750−0.659 (− 1.147; − 0.241)1.3551.1091.602 < 0.001
FEV1/FVC720.749 ± 0.0480.752 (0.713; 0.785)510.642 ± 0.0790.652 (0.595; 0.697)0.1070.0820.132 < 0.001

Reference values were calculated according to Quanjer et al. [1]

p-values below 0.05 are shown in bold

Spirometric parameters Reference values were calculated according to Quanjer et al. [1] p-values below 0.05 are shown in bold

Body plethysmography

sGaw and Gaw in terms of %predicted were different between both groups (p < 0.001 each; Table 3). In 13.8% of subjects (31.4% LED, 1.4% UED) sGaw was below the 5th percentile [14]. TLCpleth was lower (Δ = 10.9%pred) in LED subjects (p < 0.001), whereas no significant differences occurred for RV and ITGV. RV/TLCpleth and ITGV/TLCpleth were higher (Δ = 14.0%pred and Δ = 10.3%pred, respectively; p < 0.001 each) in the LED group (Table 3).
Table 3

Body plethysmographic parameters

ParameterUED groupLED groupMean difference (UED-LED)95% CI of differencep-value for difference
NumberMean ± SDMedian (25%; 75%)NumberMean ± SDMedian (25%; 75%)LowerUpper
TLCpleth %pred72113.2 ± 11.9115.9 (104.8; 122.2)51102.3 ± 12.4102.6 (94.4; 112.2)10.96.515.4 < 0.001
RV %pred7294.4 ± 16.796.6 (82.9; 103.5)5199.7 ± 18.5102.5 (92.1; 110.5)−5.3−11.81.10.104
RV/TLCpleth %pred7284.9 ± 9.485.2 (78.1; 91.7)5198.9 ± 11.998.0 (91.2; 108.0)−14.0− 18.0− 10.0 < 0.001
ITGV %pred7299.7 ± 18.8100.4 (85.8; 110.2)51101.3 ± 19.5101.1 (86.2; 118.0)−1.6−8.55.40.656
ITGV/TLCpleth %pred7283.8 ± 9.083.1 (76.8; 89.9)5194.1 ± 10.493.8 (86.9; 102.1)−10.3− 13.9−6.7 < 0.001
GAW %pred72125.7 ± 40.1121.0 (97.8; 145.3)5177.2 ± 36.170.2 (52.0; 97.6)48.634.862.3 < 0.001
sGAW %pred72138.4 ± 42.1134.6 (112.8; 153.2)5188.3 ± 47.784.2 (62.3; 107.7)50.033.566.5 < 0.001

Reference values were calculated according to Koch et al. [14]

p-values below 0.05 are shown in bold

Body plethysmographic parameters Reference values were calculated according to Koch et al. [14] p-values below 0.05 are shown in bold

CO and NO uptake of the lung

The transfer factors TLCO (p < 0.001), TLNO (p < 0.001) and the ratio TLNO/TLCO (p < 0.001) were lower in the LED group, whereas no significant differences occurred for the transfer coefficients TLCO/VA (KCO) and TLNO/VA (KNO) (Table 4). There were also significant differences regarding the ratio TLCHe/TLCpleth with higher values in the UED subjects (p < 0.05). Haemoglobin levels for which CO transfer factors were corrected did not significantly differ between LED and UED subjects.
Table 4

Parameters of the diffusing capacity for CO and NO

ParameterUED groupLED groupMean difference (UED-LED)95% CI of differencep-value for difference
NumberMean ± SDMedian (25%; 75%)NumberMean ± SDMedian (25%; 75%)LowerUpper
TLCO %pred7092.1 ± 16.789.8 (81.3; 102.2)5182.2 ± 14.283.2 (68.4; 92.9)9.84.315.4 0.001
KCO %pred7098.6 ± 16.798.7 (89.0; 110.3)51101.8 ± 17.7100.1 (89.3; 112.1)−3.2−9.53.10.316
TLNO %pred7095.0 ± 17.494.1 (83.8; 106.2)5180.0 ± 14.879.6 (70.1; 92.1)15.09.220.8 < 0.001
KNO %pred70102.7 ± 17.8102.5 (93.3; 113.9)51100.0 ± 16.5101.1 (87.4; 108.5)2.7−3.68.90.400
TLNO/TLCO704.74 ± 0.344.67 (4.54; 4.92)514.53 ± 0.294.52 (4.36; 4.65)0.210.100.33 < 0.001
TLCHe/TLCpleth700.834 ± 0.0520.832 (0.798; 0.867)510.806 ± 0.0710.810 (0.755; 0.851)0.0280.0050.052 0.018
Hb, mg/dl5313.9 ± 1.113.9 (13.2; 14.8)4813.7 ± 1.313.7 (12.8; 14.5)0.2−0.30.70.469

Reference values were calculated according to van der Lee et al. [15]

p-values below 0.05 are shown in bold

Parameters of the diffusing capacity for CO and NO Reference values were calculated according to van der Lee et al. [15] p-values below 0.05 are shown in bold

Respiratory pump function, 6-min-walk distance and biomarkers

PImax was lower in LED subjects (Δ = 11.0%pred), while P01 and P01/PImax were higher (p < 0.001 each; Table 5). LED subjects had a lower 6MWD (Δ = 14.1%pred) than UED subjects (p < 0.001). Moreover, baseline values of perceived fatigue and dyspnoea during the walk test were higher in LED subjects (p = 0.001 and p = 0.025, respectively; Table 5).
Table 5

Parameters of respiratory pump function, exercise capacity and biomarkers

ParameterUED groupLED groupMean difference (UED-LED)95% CI of differencep-value for difference
NumberMean ± SDMedian (25%; 75%)NumberMean ± SDMedian (25%; 75%)lowerupper
PImax %pred66102.9 ± 34.0100.7 (81.5; 123.2)5091.9 ± 31.990.9 (70.4; 111.0)11.0−1.323.30.079
log10(P01, kPa)66−0.72 ± 0.22− 0.69 (− 0.89; − 0.55)50−0,53 ± 0,20−0.53 (− 0.64; − 0.41)−0.19− 0.27−0.11 < 0.001
log10(P01/PImax)66−1.57 ± 0.27−1.52 (− 1.74; − 1.41)50−1.34 ± 0.30−1.34 (− 1.54; − 1.12)− 0.22− 0.33− 0.12 < 0.001
6MWD %pred71113.0 ± 17.9114.2 (98.8; 126.1)5198.9 ± 21.1101.4 (91.1; 112.4)14.16.921.4 < 0.001
PRE Dyspnoea600.06 ± 0.210.00 (0.00; 0.00)490.51 ± 0.920.00 (0.00; 1.00)− 0.45−0.72− 0.18 0.001
POST Dyspnoea601.63 ± 1.511.00 (0.50; 3.00)492.62 ± 1.783.00 (1.00; 4.00)−1.00− 1.63−0.36 0.002
PRE Fatigue600.26 ± 0.610.00 (0.00; 0.00)490.62 ± 0.970.00 (0.00; 1.00)−0.36−0.68− 0.05 0.025
POST Fatigue600.61 ± 1.200.00 (0.00; 0.88)491.09 ± 1.300.50 (0.00; 2.00)−0.48−0.96− 0.01 0.048
eCO, ppm723.5 ± 1.33.0 (3.0; 4.0)514.4 ± 1.24.0 (3.0; 5.0)−0.8−1.3−0.4 < 0.001
log10(FeNO, ppb)721.305 ± 0.1641.306 (1.206; 1.422)511.334 ± 0.2221.317 (1.179; 1.508)−0.029−0.1020.0440.433
serum 8-OHdG, ng/mL720.181 ± 0.0650.186 (0.129; 0.228)500.178 ± 0.0650.180 (0.144; 0.212)0.002−0.0220.0260.845
Telomere length, T/S ratio721.562 ± 0.2441.564 (1.412; 1.699)501.489 ± 0.1791.472 (1.344; 1.609)0.073−0.0030.1490.058

Reference values were calculated according to Enright et al. [16] for PImax and according to Enright and Sherrill [17] for 6MWD

p-values below 0.05 are shown in bold

Parameters of respiratory pump function, exercise capacity and biomarkers Reference values were calculated according to Enright et al. [16] for PImax and according to Enright and Sherrill [17] for 6MWD p-values below 0.05 are shown in bold No significant differences between both groups were found for FeNO (Table 5). eCO was slightly higher (Δ = 0.8 ppm) in LED versus UED subjects (p < 0.001). For 8-OHdG no significant difference between groups was observed. The same was true for telomere length but there was a tendency towards shorter telomeres in LED subjects (p = 0.058).

Correlation of functional indices with biomarkers

In multiple regression analyses including all subjects, no significant relationships between lung function indices and telomere length or 8-OHdG levels were found, except for a positive association between RV/TLC and telomere length (p = 0.048).

Discussion

In the present study we compared two subgroups from a larger population-based cohort which were selected to show FEV1 either at the lower end (LED) or the upper end (UED) of the distribution in the whole cohort. These subgroups were selected to be lung-healthy according to clinical history, symptoms and risk factors. The broad set of parameters allowed to compare the two groups regarding a number of functional domains. Deteriorations in spirometric values are sometimes interpreted as indicators of premature aging of the lung [2] but it is not clear whether these reflect a general respiratory status that would justify the terminology of an individual (overall) “lung age”. The adequacy of this notion can only be evaluated by comparison of a broad panel of lung function parameters, preferentially in a longitudinal cohort. However, the comparison between parameters should also be possible in carefully selected individuals of a cross-sectional analysis. Our study was suited for such a comparison, as it comprised spirometry, body plethysmography, transfer factors for CO and NO, and respiratory pump function. Additionally, telomere length of peripheral blood leukocytes and 8-OHdG were included as markers of biological age and stress. We found a difference of about 40% predicted FEV1 between the LED and UED group. This was the result of the definition of both groups but nonetheless reflected the huge difference in FEV1 even among lung-healthy elderly subjects. The differences in FVC and in FEV1/FVC were smaller. On the other hand, those of the FEFs as well as airway conductance and specific airway conductance were even larger. The scales of these parameters were comparable with each other, since airway conductance was chosen instead of resistance and impairment was always associated with a reduction towards zero. The comparison with the differences in plethysmographic volume parameters was less straightforward, since in principle, although not in practice, there is no upper bound of these parameters and no commonly accepted transformation analogous to conductance. Based on the differences in scale and physiologically possible range, it is understandable that the volume parameters showed smaller differences between the two groups. In contrast, NO and CO transfer factors also decrease upon impairment, having zero as lower bound, and are in this respect comparable to the spirometric and airway conductance parameters. Despite this similarity the differences between LED and UED groups were only about 10% in case of TLCO and about 15% in case of TLNO. Both of these parameters involve lung volume, therefore the transfer coefficients which in first order correct for volume are of particular interest, as CO diffusing capacity is sensitive to changes pulmonary capillary blood volume and NO diffusing capacity to those of the diffusion barrier. Both are likely to be affected by aging processes, thus a general aging of the lung should also have effects. Remarkably, however, the differences in KCO and KNO between the two groups were small and not significantly different from zero indicating that the differences in transfer factors were primarily due to differences in volume, i.e. of lung-mechanical nature. KCO values were also similar when using the reference values by Garcia-Rio et al. [19] for KCO (84.4%pred in UED vs. 82.9%pred in LED subjects). Moreover, the 95%-confidence intervals for the differences in transfer factors and coefficients did not overlap with those of FEV1%pred and FVC%pred as well as airway conductance. There were no significant differences in Hb values which might have influenced the values of the CO transfer factor despite the correction for Hb. The differences in PImax they were lower than those of FEV1 and sGAW, which showed values in a range of 30%pred or more, but still beyond 10%pred and larger than those of transfer coefficients KCO and KNO. Overall, these observations indicated a marked difference between the lung-mechanical and gas uptake domains. Regarding the concept of a general “lung age” our observations suggest that a differentiated description of functional domains is more adequate. The difference in 6MWD between the LED and UED group was between those of mechanical and gas exchange parameters. Dyspnoea and fatigue scores could not be scaled as percent predicted, therefore their differences were not directly comparable to the other parameters. Still, the fact that they differed between the two groups, in terms of pre and post values, indicated a greater 6MWD and at the same time lower dyspnoea and fatigue in subjects of the UED group. FeNO was included as it might indicate eosinophilic airway inflammation if elevated, or oxidative stress if decreased, but no significant differences were found. There was a small difference regarding eCO despite the fact that we had excluded current smokers and subjects with values > 6 ppm. The source of this small difference might be unreported active or passive smoking, or endogenous production related to oxidative stress [20]. However, serum 8-OHdG, as an indicator of systemic oxidative stress, was similar in the two groups. The same was true for telomere length in peripheral blood leukocytes which is often considered as a marker of biological age and/or stress but there was a tendency (p = 0.058) towards decreased telomere length in the LED group. One might argue that the results in terms of percent predicted values simply reflected different coefficients of age-dependence in the reference equations despite the fact that the mean age was similar in the two groups. To evaluate this we inserted the measured values into the respective reference equations and solved for the age that resulted in the observed values; for non-linear equations (e.g. GLI) linear approximations within the adequate range were used. This analysis was not meaningful for all parameters as it made sense only with an obvious and monotonous relationship to age to avoid absurd individual age estimates. Figure 1 shows median values and quartiles for FEV1, FVC, FEF25–75, FEF75, ITGV/TLC, KCO and KNO. It illustrates the large differences for mechanical versus much smaller differences for gas uptake parameters, taking into account the coefficients of age-dependence via the prediction equations.
Fig. 1

Median “functional age” of UED (white) and LED (grey) subjects for selected parameters; whiskers indicate lower and upper quartiles, the dashed black line indicates the mean chronological age of all subjects. Please note that lower “functional age” is associated with, for example, higher values of FEV1%pred

Median “functional age” of UED (white) and LED (grey) subjects for selected parameters; whiskers indicate lower and upper quartiles, the dashed black line indicates the mean chronological age of all subjects. Please note that lower “functional age” is associated with, for example, higher values of FEV1%pred As one of the limitations of our study, we did not measure individual rates of ageing. Still, the cross-sectional analysis used by us allowed for the comparison of different functional domains. Naturally, it is not possible to decide whether the differences between the two groups existed from the beginning, i.e. from young age, or whether they developed over time [21], e.g. due to environmental factors and cigarette smoke exposure. Therefore, an interpretation of our data in terms of “aging” or “premature aging” is not straightforward, since even telomere length might also have been shorter from the beginning. This objection does, however, not compromise the aim of our study which was the analysis of the notion “lung age” that is commonly derived from spirometry alone. The sample size of n = 123 did not allow to adjust for a broad variety of potential confounders; we therefore present only pairwise comparisons. Adjustment for weight or sex did not markedly change the results. Furthermore, it was not possible to directly compare all parameters, either because no reference values were available, or because, e.g. for ITGV, pathological changes can occur in both directions and scales were different. Our study has the strength of a broad panel of high-quality assessments that allowed direct comparisons in the same subjects. This aspect seems particularly important in view of the marked differences between the functional domains.

Conclusions

Two groups of elderly, lung-healthy subjects were chosen from the lower and upper end of the distribution of FEV1%predicted from a population-based sample. The differences of lung function parameters between groups depended on the functional domain. While those of FEV1, FVC and (specific) airway conductance were large, those of KCO and KNO transfer coefficients were small and not significantly different from zero. Therefore, the differences in lung-mechanics associated with the selection of the two groups were not in parallel with those in gas uptake. Using the respective prediction equation, a “functional age” is often computed for FEV1, especially for pedagogical purposes. When adopting this approach for other parameters, the differences between groups translated into corresponding differences in the “functional ages”. This again underlined that the notion of a unique “lung age” is ill-founded, at least when referring to functional indices, and a differentiated description should be preferred.
  19 in total

1.  ATS statement: guidelines for the six-minute walk test.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  2002-07-01       Impact factor: 21.405

2.  [Recommendations of the German Airway League (Deutsche Atemwegsliga) for the determination of inspiratory muscle function].

Authors:  C-P Criée
Journal:  Pneumologie       Date:  2003-02

3.  [Multimorbidity and successful aging: the population-based KORA-Age study].

Authors:  A Peters; A Döring; K-H Ladwig; C Meisinger; B Linkohr; C Autenrieth; S E Baumeister; J Behr; A Bergner; H Bickel; M Bidlingmaier; A Dias; R T Emeny; B Fischer; E Grill; L Gorzelniak; H Hänsch; S Heidbreder; M Heier; A Horsch; D Huber; R M Huber; R A Jörres; S Kääb; S Karrasch; I Kirchberger; G Klug; B Kranz; B Kuch; M E Lacruz; O Lang; A Mielck; D Nowak; S Perz; A Schneider; H Schulz; M Müller; H Seidl; R Strobl; B Thorand; R Wende; W Weidenhammer; A-K Zimmermann; H-E Wichmann; R Holle
Journal:  Z Gerontol Geriatr       Date:  2011-12       Impact factor: 1.281

4.  Standardisation of the single-breath determination of carbon monoxide uptake in the lung.

Authors:  N Macintyre; R O Crapo; G Viegi; D C Johnson; C P M van der Grinten; V Brusasco; F Burgos; R Casaburi; A Coates; P Enright; P Gustafsson; J Hankinson; R Jensen; R McKay; M R Miller; D Navajas; O F Pedersen; R Pellegrino; J Wanger
Journal:  Eur Respir J       Date:  2005-10       Impact factor: 16.671

5.  Standardisation of spirometry.

Authors:  M R Miller; J Hankinson; V Brusasco; F Burgos; R Casaburi; A Coates; R Crapo; P Enright; C P M van der Grinten; P Gustafsson; R Jensen; D C Johnson; N MacIntyre; R McKay; D Navajas; O F Pedersen; R Pellegrino; G Viegi; J Wanger
Journal:  Eur Respir J       Date:  2005-08       Impact factor: 16.671

6.  The natural history of chronic airflow obstruction.

Authors:  C Fletcher; R Peto
Journal:  Br Med J       Date:  1977-06-25

7.  Static lung volumes and airway resistance reference values in healthy adults.

Authors:  Beate Koch; Nele Friedrich; Henry Völzke; Rudolf A Jörres; Stefan B Felix; Ralf Ewert; Christoph Schäper; Sven Gläser
Journal:  Respirology       Date:  2013-01       Impact factor: 6.424

8.  Prediction equations for single-breath diffusing capacity in subjects aged 65 to 85 years.

Authors:  Francisco Garcia-Rio; Ali Dorgham; Raul Galera; Raquel Casitas; Elizabet Martinez; Rodolfo Alvarez-Sala; Jose M Pino
Journal:  Chest       Date:  2012-07       Impact factor: 9.410

Review 9.  Exhaled carbon monoxide in airway diseases: from research findings to clinical relevance.

Authors:  Réka Gajdócsy; Ildikó Horváth
Journal:  J Breath Res       Date:  2010-11-30       Impact factor: 3.262

10.  Reference equations for the six-minute walk in healthy adults.

Authors:  P L Enright; D L Sherrill
Journal:  Am J Respir Crit Care Med       Date:  1998-11       Impact factor: 21.405

View more
  1 in total

1.  Reduced decline of lung diffusing capacity in COPD patients with diabetes and metformin treatment.

Authors:  Kathrin Kahnert; Stefan Andreas; Christina Kellerer; Johanna I Lutter; Tanja Lucke; Önder Yildirim; Mareike Lehmann; Jochen Seissler; Jürgen Behr; Marion Frankenberger; Robert Bals; Henrik Watz; Tobias Welte; Franziska C Trudzinski; Claus F Vogelmeier; Peter Alter; Rudolf A Jörres
Journal:  Sci Rep       Date:  2022-01-26       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.