Literature DB >> 29403677

Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography coupled with diode array detector and evaporative light scattering detector.

Yi-Kai Shi1, Fang Cui1, Fang-Di Hu1, Ying-Yan Bi1, Yu-Feng Ma1, Shi-Lan Feng1,2.   

Abstract

A simple and accurate high-performance liquid chromatography (HPLC) coupled with diode array detector (DAD) and evaporative light scattering detector (ELSD) was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation (ZFP). The monitoring wavelengths were 254, 275 and 328 nm. Under the optimum conditions, good separation was achieved, and the assay was fully validated in respect of precision, repeatability and accuracy. The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis (HCA), which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures. The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.

Entities:  

Keywords:  Zhenqi Fuzheng preparation; diode array detector (DAD); evaporative light scattering detector (ELSD); hierarchical cluster analysis; high-performance liquid chromatography (HPLC); quantification

Year:  2012        PMID: 29403677      PMCID: PMC5760756          DOI: 10.1016/S2095-1779(11)70004-1

Source DB:  PubMed          Journal:  J Pharm Anal        ISSN: 2214-0883


Introduction

Traditional Chinese medicines (TCMs), used for thousands of years in China, have played an important role in clinical therapy[1,2]. Therefor, to ensure the clinical efficacy and safety, overall quality control of TCMs is of significant importance[3]. However, most of the published literature has reported the qualitation or quantification of one or two types of components from only one comprising herb, and it could not be responsible for the overall quality control of the composite formulae[4]. Therefore, it seems necessary to determine the marker compounds of Chinese medicine preparation (CMP) [5]. Zhenqi Fuzheng preparation (ZFP), composed of Radix Astragali (Huangqi in Chinese) and Fructus Ligustri Lucidi (Nüzhenzi in Chinese), which has been listed in “Ministry of Health Drug Standards” of Chinese medicine formulated prescription, is commonly used in clinical practice for the treatment to improve immunity, protect bone marrow and adrenal cortex, increase leukocytes, promote the recovery of normal functions as an accessory of surgical Operation, radiotherapy or chemotherapy, and it could also be used as an adjuvant therapy of cancer[6], [7], [8], [9], [10]. It is proved that the biologically active components in Huangqi, Nüzhenzi and ZFP include isoflavonoids, triterpene sapogenins, glycosides, saponin and phenolic acids[11], [12], [13], [14]. Therefore, developing a simple and sensitive method to determine these ingredients becomes essential for quality control of this preparation. Although many analytical methods have been reported for the qualitative evaluation of the crude drug of Huangqi or Nüzhenzi, or their combined prescriptions, including high-performance liquid chromatography (HPLC)-ultraviolet (UV) or diode array detector (DAD) [15], [16], [17], thin layer chromatography scanning (TLCS)[18], chemiluminescence-mass spectrometry (LC-MS)[19], [20], [21], [22], and HPLC-evaporative light scattering detector (ELSD) [23], there is no report on simultaneous determination of the six components as yet. In the present study, we developed the HPLC-DAD-ELSD method to determine six components of ZFP, including adenosine (1), rhodioside (2), chlorogenic acid (3), calycosin (4), fermononetin (5), and astragaloside IV (6), as shown in Figure 1. This approach is potentially ideal for routine analysis and quality evaluation of ZFP. In order to improve the sensitivity and selectivity of the determination, DAD at three different wavelengths was employed for the quantitative analysis of strong UV absorbing compounds such as phenolic acids and isoflavones due to their different UV characteristics, while ELSD was used to determine none or poor UV absorbing compounds such as saponins.
Figure 1

Structures of six standard substances

Structures of six standard substances

Experimental

1 Instruments

HPLC analysis was carried out with a Waters Liquid Chromatography (Alliance, USA), 2996 diode array detector and evaporative light scattering detector (Alltech, USA), a Waters 717 automatic injector and M32 ADD-ON single system, using a Hypersil ODS column (4.6 mm × 250 mm, 5 μm, Dalian Elite Analytical Instruments Co., Ltd., Dalian, China).

Chromatographie conditions

The mobile phase consisted of methanol (A) and water (B) in a gradient elution mode as follows: 0–10 min, A:B (10:90, v/v); 10–30 min, linear gradient from A:B (10:90, v/v) to A:B (40:60, v/v); 30–65 min, linear gradient to A:B (60:40, v/v); 65–90 min, the linear gradient to A:B (100:0, v/v). The column temperature was maintained at 30°C and the flow rate was 1. 0 mL/min. An aliquot of 10 μL of each sample was injeeted. Detection wavelengths were set at 254 nm for adenosine, calycosin, and fermononetin, 275 nm for rhodioside, and 328 nm for chlorogenic acid. The drift tube temperature for ELSD and carrier gas flow rate were 115°C and 3.0L/min, respectively.

Chemicals and samples

Compounds (4) (99.83% purity) and (5) (99.37% purity) were supplied by Shanghai Institute of Chinese Materia Medica (Shanghai, China), and the other standard substances (1, 2, 3, and 6) were purchased from National Institute for the Control of Pharmaceutical and Biological Products (Beijing, China). Methanol (HPLC grade) was provided by Yuwang Chemical Co., Ltd. (Shandong, China). All solutions were prepared with double-deionized water. Other reagents were all of analytical grade. Thirty-one batches of ZFP were obtained from different pharmaceutical companies in China.

Preparation of sample solutions and negative control (NC) solutions

ZFPs were triturated in the particle size of 40–60 mesh. The accurately weighed powder (2.0000 g) was extracted three times with aliquots of 30 mL methanol by sonication (400 W, 30 min). Then the pooled filtrate was concentrated to dryness, and the residue was dissolved in 5 mL methanol. The methanol solution was filtered with a 0.45 μm membrane prior to HPLC analysis. According to the prescription and preparation protocol of ZFP recorded in Chinese Ministry of Health Drug Standards, two kinds of NC samples in which the formula contained no Nüzhenzi (B1) and Huangqi (B2), respectively, were prepared to validate the speeificity of the method. The NC sample solutions were prepared using the same method as the sample solutions.

Standard calibration curves

Standard stock solutions of the compounds 1–6 were prepared by dissolving precisely weighted portions of the standards in methanol to give the concentrations of 0.322, 0.422, 0.502, 0.526, 0.182, and 1.695 mg/mL, respectively. The stock solutions were further diluted with methanol to get 9 different concentrations (equivalent to 1/20, 1/10, 3/20, 1/5, 1/4, 3/10, 7/20, 2/5, and 1/2 of the original concentration). Subsequently, an aliquot of 10 μL of the resulting solutions was injeeted into HPLC for analysis.

Results and discussion

Development of extraction method

To obtain quantitative extraction, the main experiment factors including extraction solvent (methanol and ethanol), extraction method (Soxhlet extraction and ultrasonic extraction) and extraction time (15, 30, and 45 min) were investigated, and the optimal conditions are presented in detail in Section 2.4.

Optimization of chromatographie conditions

To optimize the chromatographie conditions, the different stationary phases, such as Kromasil ODS column (5μ, 4.6 mm × 25 mm) and Hypersil ODS–1 column (5μ, 4.6 mm×25 mm), and different mobile phases, such as methanol: water and acetonitrile: water, were attempted during the experiment. As a result, a Kromasil ODS column and the mobile phase of methanol: water were chosen to obtain the desired separation and acceptable tailing factor within the running time of 90 min. In our previous work (data not shown), these bioactive components have slightly different UV absorption properties, and it is difficult to simultaneously determine them by common analytical approaches. Therefore, three detection wavelengths at 254, 275, and 328 nm were used to record chromatograms for the different structural types of components, and to provide an optimum S/N for simultaneously quantitative analysis. The operating conditions for ELSD were optimized according to the data computed with the ELSD software: The gas flow rate was set at 3.0 L/min, and the drift tube temperature was determined to be 115°C. Chromatograms of ZFP under such detection conditions are shown in Figure 2 and Figure 3.
Figure 2

The typical HPLC-DAD chromatographic profiles. A, B, C, and D stand for standard solution, ZFP in absence of Nüzhenzi, ZFP in absence of Huangqi, and ZFP in sequence. Peaks 1, 2, 3, 4, and 5 represent adenosine, rhodioside, chlorogenic acid, calycosin, and fermononetin, respectively. Blank sample analysis confirms that no impurities were co-eluted with the compounds determined.

Figure 3

The typical HPLC-ELSD chromatographic profiles. A, B, and C stand for standard solution, ZFP in absence of Nüzhenzi, and ZFP in sequence. NC sample analysis confirms that no impurities were co-eluted with the compounds determined.

The typical HPLC-DAD chromatographic profiles. A, B, C, and D stand for standard solution, ZFP in absence of Nüzhenzi, ZFP in absence of Huangqi, and ZFP in sequence. Peaks 1, 2, 3, 4, and 5 represent adenosine, rhodioside, chlorogenic acid, calycosin, and fermononetin, respectively. Blank sample analysis confirms that no impurities were co-eluted with the compounds determined. The typical HPLC-ELSD chromatographic profiles. A, B, and C stand for standard solution, ZFP in absence of Nüzhenzi, and ZFP in sequence. NC sample analysis confirms that no impurities were co-eluted with the compounds determined. Based on the selected detection mode, all these six compounds had acceptable limits of detection (LOD) and quantification (LOQ) (Table 1). The identity of each peak detected in ZFP samples was confirmed by comparison of retention time, UV spectrum of each peak with those of reference compound and blank samples. In addition, spiking samples with the reference compounds further confirmed the identities of the peaks.
Table 1

Regression data, LODs and LOQs of six analytes by HPLC-DAD and HPLC-ELSD

AnalyteCalibration curvearLinear range (μg)LOD (ng)LOQ (ng)
AdenosineY=8.18 × 104X− 5.79 × 1040.99990.161−1.12610.615.1
RhodiosideY= 6.08 × 104X− 1.11 × 1040.99990.211−1.2665.38.7
Chlorogenic acidY=7.18 × 104X− 1.48 × 1050.99920.251−1.5062.94.2
CalycosinY= 3.24 × 105X− 1.03 × 1060.99930.263−1.5782.13.9
FermononetinY=9.67 × 104X− 3.67 × 1050.99900.182−0.5462.54.2
Astragaloside IVA =1.35 B + 3.910.99970.848−5.08596128

Y is the peak area in UV chromatograms monitored at detection wavelengths, X is the compound amount injected, and A, B are the logarithmic values of area and amount injected in ELSD chromatograms.

Regression data, LODs and LOQs of six analytes by HPLC-DAD and HPLC-ELSD Y is the peak area in UV chromatograms monitored at detection wavelengths, X is the compound amount injected, and A, B are the logarithmic values of area and amount injected in ELSD chromatograms.

Validation of the method

Linearity, LOD and LOQ

The construetion of calibration curves was carried out according to the section 2.5. For the components by UV detection, their regression equations were expressed by the formula Y = AX + B, while by ELSD detection, their regression equations could be described as Y= aXb; so, the calibration curves should be obtained in double logarithmic coordinates[11]. As shown in Table 1, a good linearity (r>0.999) was observed in a relatively wide concentration range. Working solution was diluted with methanol to get a series of appropriate concentrations, and the LOD and LOQ under the chromatographic conditions were separately determined at the signal-to-noise ratios (S/N) of 3 and 10. LOD and LOQ for each compound are also listed in Table 1.

Precision, repeatability, and accuracy

The precision of this newly developed method was studied by determining intra-day and inter-day variations. The intra-day variation was determined by analyzing the same standard methanol solution in triplicate for three times within one day. While for interday variation test, the solution was examined in triplicate for consecutive three days. To estimate the repeatability, five different working solutions, which were prepared from the same sample, were analyzed. As indicated in Table 2, the overall RSDs of the precision test and the repeatability test were lower than 2.63%, which demonstrates good precision and repeatability of the method.
Table 2

Precision and repeatability of the six analytes

AnalytePrecision
Repeatability (n = 5)
Intra-day (n=3)
Inter-day (n = 3)
Mean (mg/g)RSD(%)Mean (mg/g)RSD (%)Mean (mg/mL)RSD (%)
Adenosine0.31561.360.31571.820.04372.32
Rhodioside0.43031.320.42982.410.47832.58
Chlorogenic acid0.49701.350.49751.570.05711.85
Calycosin0.52071.100.53092.360.35032.63
Fermononetin0.17841.780.17982.130.28092.27
Astragaloside IV1.72010.951.67781.180.64501.54

The overall RSD of the intra- and inter-day is in the range of 0.95%–1.36% and 1.18%–2.41%, respectively. And the RSD of repeatability test is <3%.

Precision and repeatability of the six analytes The overall RSD of the intra- and inter-day is in the range of 0.95%–1.36% and 1.18%–2.41%, respectively. And the RSD of repeatability test is <3%. The accuracy of the method was evaluated by spiking known amounts of standard samples into a ZFP sample and comparing the amount determined of these Standards with the amount originally added. And as shown in Table 3, the overall RSD of the recovery of ZFP was lower than 3% for all these analyses. The recovery obtained was in the range of 95.4%–103.5%, indicating that the developed method was sufficiently accurate for determining the six bioactive components in ZFP, and analysis of NC samples confirmed that no impurities were co-eluted with the compounds determined (Figure 2 and Figure 3).
Table 3

Recovery of the six analytes

AnalyteOriginal mean (mg)Spiked mean (mg)Found mean (mg)Recovery mean (mg)RSD (%) (n = 3)
Adenosine0.08740.08660.172698.42.95
Rhodioside0.95660.90651.8738101.21.76
Chlorogenic acid0.11420.09020.202498.32.82
Calycosin0.70060.68821.3930100.61.56
Fermononetin0.56180.55341.089695.42.93
Astragaloside IV1.28251.27942.6067103.52.79

Table 3 shows the accuracy of repeatability test with RSD <3%. Recovery mean (%) = [(Found mean-Original mean)/Spiked mean] × 100

Recovery of the six analytes Table 3 shows the accuracy of repeatability test with RSD <3%. Recovery mean (%) = [(Found mean-Original mean)/Spiked mean] × 100

Analysis of samples

The developed method was subsequently applied to simultaneous determination of the six active compounds in 31 commercial ZFP samples from different pharmaceutical companies in China. All the contents of six ingredients in 31 batches of ZFP samples are summarized in Table 4. The results showed that the quality of this preparation was relatively uniform and demonstrated that the chemical variation was obvious among the different companies and/or preparations of ZFP.
Table 4

Content of six compounds in 31 batches of ZFP samples (mg/g)

Sample No.AdenosineRhodiosideRhlorogenic acidCalycosinFermononetinAstragaloside IV
10.04370.47830.05710.35030.28090.6450
20.04000.39530.05540.33940.32140.6384
30.05000.40820.05020.32520.24840.6294
40.04740.42170.05760.37010.31200.6755
50.04500.43230.05390.34590.27180.6602
60.02650.47720.05450.31890.27490.6625
70.02830.45330.05950.30700.26500.6767
80.02940.47730.06400.32650.20000.6416
90.02680.39350.06330.32910.23800.6606
100.03180.63950.03490.26010.30060.6275
110.03100.73870.03440.25990.21130.6780
120.02340.41370.03480.23470.21880.6167
130.02970.36000.02190.26500.21650.6405
140.02940.16480.02140.19560.25470.6306
150.03520.28850.03020.28900.25400.6620
160.04350.38520.03390.22710.25390.6029
170.03440.27110.03530.19580.19990.6346
180.03000.31910.03060.26770.23680.6865
190.03870.30220.02550.21700.19330.7406
200.04500.27150.03320.33410.34890.8776
210.04470.16780.03700.35940.32860.8484
220.02660.16930.03430.36730.29860.8890
230.02540.18970.03830.34420.37210.9180
240.00520.31540.06160.39780.31150.7820
250.00520.29270.05980.36790.30390.7685
260.00500.35400.04140.36650.32780.7969
270.00100.33810.06250.34910.30730.8012
280.00881.47420.08830.32160.25710.6030
290.01010.07470.02260.21710.12470.7024
300.01530.15760.01220.15440.12910.5575
310.01330.38060.02170.20450.16710.6367
Content of six compounds in 31 batches of ZFP samples (mg/g) The results showed that the content of astragaloside IV (6), a characteristic and active constituent whose presence forms part of the quality assurance of ZFP, is relative high in samples compared with the other target compositions. The contents of the compounds were found lower in granule, and higher in capsule, except compound 2. Therefore, the analytical results obtained also indicated that a multiple-component assay might be a rational strategy to elceidate the synergic effects and much more comprehensive control for the quality of this preparation.

Comparison of different batches of ZFP

To evaluate the variation of ZFP, hierarchical cluster analysis (HCA) was performed based on the investigated components’ characteristics from HPLC profiles of 31 test samples. The dendrogram of HCA is shown in Figure 4, and the quality characteristics are revealed more clearly. Supposing an appropriate distance level (Level I) is chosen, the samples can be classified into seven quality groups, thereby indicating that preparation procedure is related to the quality of products. If a higher distance level (Level II) is adopted, samples 1–19 tend to be classified into the same group, which indicates that the samples from the same manufacturer are more similar, and then the samples can be divided into five quality groups, among which there is an abnormal sample (No.28). Thus, HCA is an effective way to discover the abnormal sample rapidly.
Figure 4

The cluster analysis of chromatograms of 31 ZFP samples. Level I was used to distinguish different dosage forms of preparation. Level IT was used to distinguish different manufacturers of samples 1–19. An abnormal sample (No.28) can be discovered obviously.

The cluster analysis of chromatograms of 31 ZFP samples. Level I was used to distinguish different dosage forms of preparation. Level IT was used to distinguish different manufacturers of samples 1–19. An abnormal sample (No.28) can be discovered obviously.

Conclusion

We reported a simple and sensitive HPLC method coupled with DAD and ELSD, and these two detectors are complementary. The proposed HPLC-DAD-ELSD method makes it possible to evaluate the quality of ZFP through a determination of multi-components with different structures. This method has been applied successfully to quantify six bioactive compounds in 31 different batches of ZFP samples. The results prove that the present method is suitable for routine quantitative analysis and intrinsic quality control of ZFP.
  10 in total

1.  Studying traditional Chinese medicine.

Authors:  Tianhan Xue; Rustum Roy
Journal:  Science       Date:  2003-05-02       Impact factor: 47.728

2.  Asian medicine. The new face of traditional Chinese medicine.

Authors:  Dennis Normile
Journal:  Science       Date:  2003-01-10       Impact factor: 47.728

3.  Determination and identification of isoflavonoids in Radix astragali by matrix solid-phase dispersion extraction and high-performance liquid chromatography with photodiode array and mass spectrometric detection.

Authors:  H B Xiao; M Krucker; K Albert; X M Liang
Journal:  J Chromatogr A       Date:  2004-04-02       Impact factor: 4.759

4.  Simultaneous determination of six isoflavonoids in commercial Radix Astragali by HPLC-UV.

Authors:  Tao Wu; S W Annie Bligh; Li-hua Gu; Zheng-tao Wang; He-ping Liu; Xue-mei Cheng; Chris J Branford-White; Zhi-bi Hu
Journal:  Fitoterapia       Date:  2005-03       Impact factor: 2.882

5.  Simultaneous determination of nine components in Qingkailing injection by HPLC/ELSD/DAD and its application to the quality control.

Authors:  Shikai Yan; Guoan Luo; Yiming Wang; Yiyu Cheng
Journal:  J Pharm Biomed Anal       Date:  2005-10-27       Impact factor: 3.935

6.  Simultaneous determination of eight active components in Chinese medicine 'YIQING' capsule using high-performance liquid chromatography.

Authors:  Haibin Qu; Yanhong Ma; Ke Yu; Yiyu Cheng
Journal:  J Pharm Biomed Anal       Date:  2006-07-18       Impact factor: 3.935

7.  Improved quality control method for Fufang Danshen preparations through simultaneous determination of phenolic acids, saponins and diterpenoid quinones by HPLC coupled with diode array and evaporative light scattering detectors.

Authors:  Ying-Jie Wei; Lian-Wen Qi; Ping Li; Hou-Wei Luo; Ling Yi; Liang-Hong Sheng
Journal:  J Pharm Biomed Anal       Date:  2007-07-20       Impact factor: 3.935

8.  [Analysis of total saponins in traditional Chinese drug radix Astragali].

Authors:  F Pan; Y Feng; S Chen; G Gao
Journal:  Zhongguo Zhong Yao Za Zhi       Date:  1995-07

9.  Capillary liquid chromatography-microcoil 1H nuclear magnetic resonance spectroscopy and liquid chromatography-ion trap mass spectrometry for on-line structure elucidation of isoflavones in Radix astragali.

Authors:  H B Xiao; M Krucker; K Putzbach; K Albert
Journal:  J Chromatogr A       Date:  2005-03-04       Impact factor: 4.759

10.  [Determination of 6 isoflavonoids in the hairy root cultures of Astragalus membranaceus by HPLC].

Authors:  Z Zheng; C Song; D Liu; Z Hu
Journal:  Yao Xue Xue Bao       Date:  1998
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.