Literature DB >> 29398091

Correlation between Temperature-dependent Fatigue Resistance and Differential Scanning Calorimetry Analysis for 2 Contemporary Rotary Instruments.

Ana Arias1, José C Macorra2, Sanjay Govindjee3, Ove A Peters4.   

Abstract

INTRODUCTION: The aim of this study was to assess differences in cyclic fatigue (CF) life of contemporary heat-treated nickel-titanium rotary instruments at room and body temperatures and to document corresponding phase transformations.
METHODS: Forty Hyflex EDM (H-EDM) files (Coltene, Cuyahoga Falls, OH [#25/.08, manufactured by electrical discharge machining]) and 40 TRUShape (TS) files (Dentsply Tulsa Dental Specialties, Tulsa, OK [#25/.06v, manufactured by grinding and shape setting]) were divided into 2 groups (n = 20) for CF resistance tests in a water bath either at room (22°C ± 0.5°C) or body temperature (37°C ± 0.5°C). Instruments were rotated in a simulated canal (angle = 60°, radius = 3 mm, and center of the curvature 5 mm from the tip) until fracture occurred. The motor was controlled by an electric circuit that was interrupted after instrument fracture. The mean half-life and beta and eta Weibull parameters were determined and compared. Two instruments of each brand were subjected to differential scanning calorimetry (DSC).
RESULTS: While TS instruments lasted significantly longer at room temperature (mean life = 234.7 seconds; 95% confidence interval [CI], 209-263.6) than at body temperature (mean life = 83.2 seconds; 95% CI, 76-91.1), temperature did not affect H-EDM behavior (room temperature mean life = 725.4 seconds; 95% CI, 658.8-798.8 and body temperature mean life = 717.9 seconds; 95% CI, 636.8-809.3). H-EDM instruments significantly outlasted TS instruments at both temperatures. At body temperature, TS was predominantly austenitic, whereas H-EDM was martensitic or in R-phase. TS was in a mixed austenitic/martensitic phase at 22°C, whereas H-EDM was in the same state as at 37°C.
CONCLUSIONS: H-EDM had a longer fatigue life than TS, which showed a marked decrease in fatigue life at body temperature; neither the life span nor the state of the microstructure in the DSC differed for H-EDM between room or body temperature.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 29398091     DOI: 10.1016/j.joen.2017.11.022

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

2.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

3.  Bending resistance and cyclic fatigue resistance of WaveOne Gold, Reciproc Blue, and HyFlex EDM instruments.

Authors:  Soram Oh; Kee-Yeon Kum; Hyun-Jung Kim; Su-Young Moon; Hyeon-Cheol Kim; Antonis Chaniotis; Hiran Perinpanayagam; Eugenio Pedullá; Seok Woo Chang
Journal:  J Dent Sci       Date:  2019-12-30       Impact factor: 2.080

4.  Cyclic Fatigue and Torsional Resistance of Four Martensite-Based Nickel Titanium Reciprocating Instruments.

Authors:  Emmanuel Silva; Carolina Oliveira de Lima; Victor Vieira; Henrique Antunes; Edson Jorge Lima Moreira; Marco Versiani
Journal:  Eur Endod J       Date:  2020-12

Review 5.  Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies.

Authors:  Selventhra Savitha; Sidhartha Sharma; Vijay Kumar; Amrita Chawla; Perumal Vanamail; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-08-02

Review 6.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12

Review 7.  Present status and future directions: Canal shaping.

Authors:  Ana Arias; Ove A Peters
Journal:  Int Endod J       Date:  2022-02-16       Impact factor: 5.165

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.