Literature DB >> 29395366

Acute intraoperative echocardiographic changes after transapical off-pump mitral valve repair with NeoChord implantation.

Andrea Colli1, Laura Besola2, Matteo Montagner2, Nicola Soriani2, Erica Manzan2, Eleonora Bizzotto2, Fabio Zucchetta2, Danila Azzolina2, Roberto Bellu3, Cristiano Sarais2, Demetrio Pittarello4, Gino Gerosa2.   

Abstract

OBJECTIVES: Our aim is to investigate the acute intraoperative effects of the NeoChord repair procedure on mitral valve (MV) annular geometry and LV function and the impact of these changes on MR at 1-year follow-up.
BACKGROUND: Recently transapical off-pump mitral valve repair with NeoChord implantation has been demonstrated to be safe and effective in patients with degenerative mitral regurgitation (DMR).
METHODS: We retrospectively analyzed baseline and early postoperative 3-dimensional transesophageal echocardiography of 66 patients who underwent NeoChord repair for isolated posterior leaflet MV disease using semiautomatic off-line analysis software.
RESULTS: We observed a significant acute reduction of indexed LV end diastolic volume (Δ% = 14, p < .001), LV ejection fraction (Δ = 5.7%, p = .002), indexed left atrial volume (Δ = 14.7%, p = .045), and pulmonary artery pressure (Δ = 2.1%, p = .026). Among MV geometric parameters, we observed a significant reduction of MV antero-posterior diameter (Δ = 7%, p < .001), sphericity index (Δ = 8%, p < .001), annulus circumference (Δ = 0.9%, p = .021), and annulus area (Δ = 2.7%, p = .018). At 1-year, 53 patients (85.5%) presented MR ≤ mild, while 9 patients (14.5%) had MR ≥ moderate. Reduction of AP diameter (OR = 0.14, CI -3.83; 0.08, p < .001), annulus circumference (OR = 0.27, CI -2.98; 0.37, p = .005), MV area (OR = 0.39, CI -2.46; 0.61, p = .04), aorto-mitral angle (OR = 0.38, CI -2.49; 0.54, p = .002) and iEDV (OR = 0.44, CI -2.44; 0.81, p = .001) were independent protective factors against recurrence of MR greater than mild at 1-year follow-up.
CONCLUSIONS: Transapical NeoChord repair produces important acute intraoperative changes in MV anatomy in DMR patients. The acute changes observed were associated with procedure durability at 1-year FU.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  3D echocardiography; Mitral annular geometry; Mitral valve flail; Mitral valve prolapse; Mitral valve regurgitation; NeoChord

Mesh:

Year:  2018        PMID: 29395366     DOI: 10.1016/j.ijcard.2018.01.026

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  6 in total

1.  Transapical off-pump echo-guided mitral valve repair with neochordae implantation mid-term outcomes.

Authors:  Gino Gerosa; Matteo Nadali; Lorenzo Longinotti; Matteo Ponzoni; Raphael Caraffa; Alessandro Fiocco; Nicola Pradegan; Laura Besola; Augusto D'Onofrio; Eleonora Bizzotto; Roberto Bellu; Denas Gentian; Andrea Colli
Journal:  Ann Cardiothorac Surg       Date:  2021-01

2.  Transapical beating heart mitral valve repair versus conventional surgery: a propensity-matched study.

Authors:  A D'Onofrio; F Mastro; M Nadali; A Fiocco; D Pittarello; P Aruta; G Evangelista; G Lorenzoni; D Gregori; G Gerosa
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-06-15

3.  Relative Impact of Surgical Mitral Repair and MitraClip on Annular Remodeling-A Potential Mechanism for Therapeutic Response to Mitral Repair for Degenerative Mitral Regurgitation.

Authors:  Lisa Q Rong; Alexandra J Lopes; Hannah W Mitlak; Maria C Palumbo; Stephanie Mick; Jiwon Kim; Robert A Levine; S Chiu Wong; Mark Reisman; Richard B Devereux; Mario Gaudino; Jonathan W Weinsaft
Journal:  J Cardiothorac Vasc Anesth       Date:  2021-09-10       Impact factor: 2.894

4.  Comparison of early postoperative results between conventional and transapical mitral valve repair.

Authors:  Aleksejus Zorinas; Artūras Lipnevicius; Viktorija Bleizgytė; Vilius Janušauskas; Daina Liekienė; Mindaugas Budra; Robertas Stasys Samalavičius; Agnė Drąsutienė; Diana Zakarkaitė; Audrius Aidietis; Kęstutis Ručinskas
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-12-08       Impact factor: 1.426

5.  Computer simulations of transapical mitral valve repair with neochordae implantation: Clinical implications.

Authors:  Andrés Caballero; Raymond McKay; Wei Sun
Journal:  JTCVS Open       Date:  2020-06-06

6.  Actual perspective on off-pump transapical artificial chord implantation.

Authors:  Matteo Saccocci; Andrea Colli
Journal:  J Card Surg       Date:  2022-02-19       Impact factor: 1.778

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.